1 PRODUKTKATALOG - STEGO TECHNICAL DATASHEET FILTER FAN PLUS FPI/FPO 176 x 176 mm > New air-flap outlet technology for > Two systems for optimal airflow high airflow (FPI/FPO) > Easy mounting > Standard enclosure cut-out sizes > Protection type test/Environmental (5 sizes) rating by independent testing institutes > One filter mat (VDE and UL) Filter fans are used to provide an optimum climate in enclosures and cabinets with electrical/electronic components. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting airflow prevents formation of localised hot pockets in installations and protects electronic components from overheating. The Filter Fan Plus series uses a new air-flap outlet technology for the air outlet and thus reaches a high degree of airflow. A ratchet mechanism is used for mounting and provides high stability and tightness. Depending on the application there are two systems that are available the FPI or FPO system. The FPI system is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is fed into the enclosure (airflow directionI). This system consists of a filter fan and exit filter. Whereas in the FPO system, the filter fan is located in the upper area of the enclosure to avoid heat buildups (airflow directionOu). The FPO system is composed of an intake filter and exit filter fan. The Filter Fan Plus series has been designed for indoor use. TECHNICAL DATA Axial fan, ball bearing service life L10 at +40 C (+104 F): min. 65,000 h fan body aluminium, rotor metal Connection 3-pole clamp for 2.5 mm, clamping torque 0.8 Nm max. Casing, hood, flaps plastic according to UL94 V-0, light grey UV light resistant according to UL746C (f1) Enclosure cut-out 176 x 176 mm SYSTEM FPI Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness 1 4 mm). 1 Additional use of screws possible if needed . Air outlet through flaps Filter mat G3 acc. to DIN EN 779, average arrestance A 84 % a Filter material synthetic fibre with progressive construction, temperature resistant to +100 C, self-extinguishing class F1, moisture resistant to 100 % RH, reusable Operating temperature 50 Hz: -25 to +50 C (-13 to +122 F) 60 Hz: -25 to +70 C (-13 to +158 F) Storage temperature -40 to +70 C (-40 to +158 F) Air intake Operating/Storage humidity max. 90 % RH (non-condensing) through filter mat with fan Protection type/Protection class IP54 / I (earthed) Environmental rating UL/NEMA UL TYPE 12 / NEMA 12 Approvals VDE, UL File No. E234324, EAC Note other voltages on request 1 Drilling marks for screw mounting are indicated on mounting frame. AIRFLOW DIRECTIONI: FILTER FAN FPI 018 Art. No. Operating voltage Air volume, Air volume Current consumption Power Average noise level Depth in Weight Filter mat free flow with exit filter (50/60 Hz) consumption (DIN EN ISO 4871) enclosure (approx.) 01872.0-30 AC 230 V, 50/60 Hz 170 m/h 113 m/h 310/250 mA 45 W 55 dB 117 mm 1.6 kg G3 01872.9-30 AC 115 V, 50/60 Hz 204 m/h 137 m/h 560/470 mA 38 W 58 dB 117 mm 1.6 kg G3 AIRFLOW DIRECTIONI: EXIT FILTER FPI 118 Art. No. Depth in enclosure Weight (approx.) Air outlet 11872.0-00 43 mm 0.4 kg air-flap outlet technology cold warm 15.10.2015 Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. www.stego.de www.stego.co.uk www.stegonorden.se2 2 PRODUKTKATALOG - STEGO TECHNICAL DATASHEET SYSTEM FPO Air outlet through flaps with fan Air intake through filter mat AIRFLOW DIRECTIONOU: FILTER FAN FPO 018 Art. No. Operating voltage Air volume, Air volume Current consumption Power Average noise level Depth in Weight air outlet free flow with exit filter (50/60 Hz) consumption (DIN EN ISO 4871) enclosure (approx.) 01882.0-00 AC 230 V, 50/60 Hz 263 m/h 137 m/h 310/250 mA 45 W 56 dB 117 mm 1.6kg air-flaps 01882.9-00 AC 115 V, 50/60 Hz 313 m/h 166 m/h 560/470 mA 38 W 60 dB 117 mm 1.6kg air-flaps AIRFLOW DIRECTIONOU: INTAKE FILTER FPO 118 Art. No. Depth in enclosure Weight (approx.) Filter mat 11882.0-30 25 mm 0.4 kg G3 acc. to DIN EN 779, average arrestance A 84 % a FILTER MAT FM 086 Filter class 168 x 168 mm Average arrestance A 1 packing unit a G3 acc. to DIN EN 779 Art. No. 08635.0-00 84 % 5 pieces 117 43 117 25 215 215 25 25 25 25 FPI 018 FPI 118 FPO 018 FPO 118 cold warm 176 176 176 176 15.10.2015 Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. www.stego.de www.stego.co.uk www.stegonorden.se