Wall mount SYS1452-Wxx series 30W Country of Origin : China Operating Temperature : 0~40 C Dimension : 82.3 x 71.1 x 34.5 mm Efficiency level (ErP) : V Approvals / Marks : Specifications Voltage DC Loading Max. Power Ripple / Noise Connector Model V A W mV p-p mm SYS1452-3012-W2E 12 0~2.5 30.1 200 2.1x5.5x9.5 Features: Output connector: standard: 2.1 x 5.5 x 9.5mm or customer requirement Regulated Output With Low Ripple Noise Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available Modified and Custom Design Available 2 Years Warranty OUTPUT EMC Turn delay 7000 ms max AC low line input output full load Meet EN550022 class B, FCCpart 15 Sub part B class B Hold up time 5ms min AC nominal input output full load (>half cycle) EN 60950-1:2006+All LVD2006/95/EC IEC 60950-1:2005 Efficiency (Normal) Meet CEC, ERP Level V 115v/60HZ,230V/50HZ SAFETY 0.3v dv max At AC nominal input loading from 50% load to max load or peak load GS CB CE Transient response (dv,tmax) 8ms tmax Dynamic rise time 10uS max , duty 40mS max , Dynamic load step is slew rate of 0.5A/uS OTHERS Power out.Limit - Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S Burn in limit Full load 2 Hours M.T.B.F 500,000 Calculated Hours at 25C, by Telcordia SR-332 Less than 0.03W rms max. At AC nominal input output no Power consumption load Cable Length 1800mm (6 feet) standard cable or as required INPUT PLD Line power surge Line vo lta ge SAG-more info on request (power line disturbance) Voltage (90~264)VAC Cooling method Natural Convection Cooling Frequency (47~63)hz Housing material PC Current 1A rms AC low line input and DC output full load Temperature coefficient: <0.5%/ Inrush Surge Current 30/60A max power supply cold start,ambient temperature (cold start) 25C 115Vac/230Vac nominal AC input ENVIRONMENT leakage current 0.25mA Max Temperature Operating: 0~40 / Storage: -20%~85%RH non condensing PROTECTION Operating: 8%~90%RH / Storage: 5%~95% RH non con- The power supply will self-protect any output to ground and Humidity densing Over current/ auto recovery when abnormal circuit faults remove. An output Short protection short circuit is defined as any output impedance of less than WEIGHT 0.1 ohms. Over Voltage The power supply will be auto recovered when faults remove 1PC NW: 127g/pc 2.0AL/250V Fuse. F2 connected from MOV(Varistor) to Input protection remaining PS circuitry to protect PS from excessive current GW: 12,3kg/box draw. The power supply is provided with no load operation to pre- PACKING No Load protection vent the power supply and system from damage. Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 64 pcs /1 box www.sunny-euro.com Wall mount SYS1452-Wxx series 30W Mechanical case specification: Cable specification: www.sunny-euro.com