Desktop SYS1548-T3 series 50W~65W China Country of Origin : Operating Temperature : 0~40 C Dimension : 115 x 55 x 35 mm Efficiency level (ErP) : VI Approvals / Marks : BIS Specifications Voltage DC Loading Max. Power Ripple / Noise Connector Model V A W mV p-p mm SYS1548-5012-T3 12 0~4.17 50 200 2.1x5.5x11 SYS1548-5024-T3 24 0~2.08 50 240 (*) SYS1548-6512-T3 12 0~5.42 65 180 2.1x5.5x11 SYS1548-6512-T3 12 0~5.42 65 180 2.5x5.5x11 SYS1548-6515-T3 15 0~4.33 65 200 2.1x5.5x11 SYS1548-6518-T3 18 0~3.61 65 240 2.1x5.5x11 SYS1548-6519-T3 19 0~3.42 65 240 2.1x5.5x11 SYS1548-6524-T3 24 0~2.71 65 300 2.1x5.5x11 SYS1548-6536-T3 36 0~1.80 65 360 2.1x5.5x11 Features: Available in 2 inlet versions: C7 (T2) C13(T3) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement Regulated Output With Low Ripple Noise Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available Modified and Custom Design Available 2 Years Warranty OUTPUT EMC Turn delay 5000ms max AC low line input output full load Meet EN550022 class B, FCCpart 15 Sub part B class B Hold up time 5ms min AC nominal input output full load (>half cycle) EN 60950-1:2006+All LVD2006/95/EC IEC 60950-1:2005+A1+A2 Meet CEC,DOE,ERP,MEPS Level Efficiency (Normal) VI 115v/60HZ,230V/50HZ SAFETY 0.4V dv max At AC nominal input loading from 20%load to UL GS CB CE FCC CCC BSMI PSE EK-Mark (only for 5012) SAA RCM NOM (only Transient response 80%load for 6012) EAC BIS (only for 6512/6012/5012) S-MARK (dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms OTHERS max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Peak 75w Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S Burn in limit Full load 2 Hours M.T.B.F 500,000 Calculated Hours at 25C, by Telcordia SR-332 Less than 0.075W ms max. At AC nominal input output min Power consumption 1500mm (5 feet) standard cable or as required load Cable Length 1200mm (4 feet) cable for SYS1548-5012-T3 INPUT PLD Line power surge Line voltage SAG-more info on request (power line disturbance) Voltage (90~264)VAC Cooling method Natural Convection Cooling Frequency (47~63)hz Current 2.0A rms AC low line input and DC output full load Housing material PC or PPO Inrush Surge Current 40/80A max power supply cold start,ambient temperature Temperature coefficient: <0.5%/ (cold start) 25C 115Vac/230Vac nominal AC input leakage current T2:0.25mA max T3:3.0mA max ENVIRONMENT PROTECTION Temperature Operating: 0~40 / Storage: 5%~90%RH non condensing The power supply will self-protect any output to ground & Operating: 8%~90%RH / Storage: 5%~95% RH non condens- Humidity Over current/ auto recovery when abnormal circuit faults remove. An output ing Short protection short circuit is defined as any output impedance less than 0.1 WEIGHT ohms. Over Voltage The power supply will be auto recovered when faults remove NW: 266g/pc F1:3.15A 250V Fuse The power supply shall be protected Input protection GW: 16kg/box against power line surges and any abnormal condition The power supply is provided with no load operation to No Load protection PACKING prevent the power supply and system from damage. PE plastic bag 60 pcs/1 box 48x44x23 cm Protection class I, (ITU-T K.21 Surge 6KV on request) www.sunny-euro.com Desktop SYS1548-T3 series 50W~65W Mechanical case Cable specification: FIX cable type (1185 16(for 12Vmodel) or 20(for 24V,48V model) or 18*1C + shield / 4FT(50W) or 5FT(65W)) www.sunny-euro.com