Miniature Switch Mode Power Supply Model Highly Accelerated H . A . L . T. Life AAD130 TESTED Testing 130 Watts output power Power Factor Correction Parallel/Redundant Operation Up to 88% Efficiency Electrical Specifications Input Voltage: 90-264 VAC, 47-63 Hz Input Current: <2A RMS 115 VAC full load <1A RMS 230 VAC full load Inrush Current: <35A, pk 132 VAC cold start <75A, pk 264 VAC cold start Power Factor: >0.98 full load 115/230VAC input Harmonic Distortion: Meets EN61000-3-2 EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15 Class B (conducted) Input Protection: Internal AC line fuse 250 VAC, 4.0A Remote Sense: Standard on V1 and V2 Up to 400mV of cable drop Output Power: 130W with 15CFM air 80W Convection AC Power Fail: TTL logic 0 at least 5 ms before DC LOW cooled (consult factory for current ratings) output drops 5% (without signal jitter). <10mA sink current for Power Fail0 . Line Regulation: 0.3% <1mA source current for Power Fail1 . Load Regulation: 1% for V1 and V2 Overshoot/Undershoot: <5% overshoot with remote sense at output 5% for V3 and V4 terminals PARD: Greater of 1% or 50mV Current Share (option): Load currents of V1 and V2 for similar units 20MHz bandwidth can be shared <5% of total load Hold-up Time: >20 ms full load Overvoltage Protect: Factory set, 125% 5% on V1 and V2 Turn-on Delay: <2 seconds cycle AC to reset Output Polarity: See Voltage Chart Short Circuit Protection: All outputs are auto recovery Minimum Load: >0.5A for V1 and V2 Reverse Voltage: Reverse current up to rated outputs >0.1A for V3 and V4 Case Power Protection: Standard operation interrupt (hiccup mode) Transient Response: Greater of 150mV or 3% for 25% Efficiency: Up to 88% load change 1A/s (V1 and V2) MTBF: MIL-STD-HDBK 217E Output Rise Time: <100 ms (10% to 90%) >200,000 hours 25C Highly Accelerated Life Testing Available Voltage Outputs* Voltage V1 V1 V2 V2 V3 V3 V4 ** V4 Codes Voltages Currents Voltages Currents Voltages Currents Voltages Currents (Volts) (Amps) (Volts) (Amps) (Volts) (Amps) (Volts) (Amps) -1 +1.8 14 +1.8 16 +1.8 1.5 -1.8 1.5 -2 +3.3 14 +3.3 16 +3.3 1.5 -3.3 1.5 -3 +5 14 +5 14 +5 1.5 -5 1.5 -4 +12 5 +12 1.5 -12 1.5 -5 +15 1.5 -15 1.5 -6 +24 1.5 -24 1.5 * Consult factory for other voltages and OEM quantities. ** Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model. Note: Standard models are 3244, 3255, 3264, 3404 and 3464 PART STRUCTURE: MODEL - VOLTAGE CODE - OPTION CODES (See back) - V1 V2 V3 V4 - AAD130 - X X X X - ABC.... Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V 14A, (V2) +3.3V 16A, (V3) +12V 1.5A and (V4) -12V 1.5A with Current Sharing and Metric Mounting. SEE 3rd page for AAD130 CODE TABLE AND AVAILABLE OPTIONS. Model AAD130 Options (code) Safety Compliance IEC / EN / UL / CSA 60950-1 6-32 PEM Nut (Standard) Current Sharing (A) CE Declaration to Low Voltage Directive 2006/95/EC and PF Invert (B) Thru-Hole Mounting (C) RoHS Directive 2011/65/EU Metric Mounting (M) PF Open Collector (O) Input and Options with Gold Pins (G) Physical Specifications Molex Output Connector with Gold Pins (J) Molex Connectors with Standard Pins (K) Dimensions: (HxWxL) 1.25 x 3.14 x 5 Operating Temp: 0 to 50C rated power to 50C Surge & ESD Test Levels with 15CFM air EN61000-4-5 Level 3 EN61000-4-2 Level 2 EN61000-3-2 EN61000-4-2 Level 3 (Air Only) Relative Humidity: 5% to 90%, non-condensing EN61000-4-4 Level 3 EN61000-4-11 Storage: -50 to 85C/20-90% RH Meets Class B conducted limits per Altitude: 6561 CISPR 11/22 and 47 CFR 15 subpt B 40,000 storage Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice. TAMURA CORPORATION OF AMERICA 1040 South Andreasen Drive, STE. 100, Escondido, CA 92029-1951 (951) 699-1270 / Fax: (951) 676-9482 (800) 472-6624 www.tamuracorp.com