Up to 16 outputs Voltages up to 48V, Current up to 300A Fast-on output connection Worldwide approvals & CB report Medical Approval Option 3 Year Warranty Key Market Segments & Applications Instrumentation Broadcast Medical ATE Alpha Series Automation Industrial Computing Security Lifesciences/Laboratory 400, 600, 1000 and 1500W Network Servers and Routers AC/DC Modular Features and Benefits Features Benefits Low Profile Simpler to install in system Fast-on output terminal Reduces installation time/errors Medical Approval available Suitable in medical applications INPUT Alpha400 90-264Vac Alpha600 90-264Vac,160-358Vdc InputVoltage Alpha1000 85-264Vac,120-360Vdc Alpha1500 85-264Vac(1000Wbelow150Vacinput) InputFrequency 47-63Hz(440HzwithreducedPFC-consultfactory) InrushCurrent <50Aat25Cand264Vac(coldstart) 250VacHBCFastActing(notuseraccessible) 10Afor400W InputFuse 12Afor600W 20Afor1000Wand1500W LeakageCurrent 1.1mAmaxat264Vac&63Hz LowerLeakageOption seeconfiguringguide PowerFactor 0.99typical OUTPUT Voltage/Current Seemoduleoutputtable TurnonDelay 1.5smax at90Vac(150VacforAlpha1500W)&100%ratedoutputpower RiseTime <50ms to90%ofvoltage,monotonicriseabove10% TurnonOvershoot <5%or250mV Loadtypedependant,noovershootwithresistiveload Efficiency 75% typicalat230Vac&100%ratedpower,configdependent at90Vac&100%ratedoutputpower Holdup 15msmin 13msfor1000W,8msfor1500Wandat207Vacfor1500W Ripple&Noise <2% (or100mVifgreater)Pk-Pk,usingEIAJtestmethod&20MHzbandwidth VoltageAccuracy <1% ofsetVoltage RemoteSense Yes Standardonsingleoutputmodules MinimumLoad No onanyoutput TemperatureCoefficient <0.02% ofratedvoltageperC LoadRegulation <0.5%or25mV for0-100%loadchange(withsenseconnected,<2%without) LineRegulation <0.5% for90-264Vacinputchange(210-264Vacfor1500W) CrossRegulation <0.2% for100%loadchangeonanyotheroutput <10% ofsetvoltagefor50%loadchange(above25%load) TransientResponseRecovery 500s forrecoveryto1%or100mVofsetvoltage(1000sforSmodule) OverVoltageProtection Standard foralloutputs OverCurrentProtection Standard foralloutputs ShortCircuitProtection <150% ofratedcurrent,whenoutputvoltage<1% OverTemperatureProtection Yes Shutsdownalloutputs.Cycleacoff/ontoreset Note shutdowntempvariesaccordingtoambient,outputpowerandinputV 1 Alpha SeriesSAFETY APPROVALS Date Amendments Date Amendments EN60950-1 2001 IEC60601-1a 1988 A1,A2 UL60950-1 2003 UL60601-1a 2003 CSA22.2No60950-1 2003 CSA60601-1 2003 a IEC60950-1* 2001 CEMark LVDirective2006/95/EC(EN60950-1) *CBCertificateandreportavailableonrequest a-OnlyforLL,RLandTLleakagevariants.CA400+CA1000only PRODUCT, GENERIC & COLLATERAL STANDARDS ComplianttoHigh LowVoltagePowerSupply,EMC EN61204-3:2001 ClassAemissionsforCA1000/CA1500 SeverityImmunity MedicalElectricalEquipment,EMC EN61601-1-2:2001 Compliant ClassAemissionsforCA1000/CA1500 Immunityforresidential,commercialandlight EN61000-6-1:2001 Compliant industrialenvironments Immunityforindustrialenvironments EN61000-6-2:2001 Compliant Emissionsforresidential,commercialand EN61000-6-3:2001 Compliant CA1000andCA1500notcompliant lightindustrialenvironments Emissionsforindustrialenvironments EN61000-6-4:2001 Compliant EMISSIONS ClassB(asperCISPR.22) Seeapplicationnotefordetails. RadiatedElectricField EN55022 ClassAforAlpha1000/1500 OnlyforStypeleakageversions ClassB(asperCISPR.22) OnlyforStypeleakageversions. ConductedEmissions EN55022 ClassAforAlpha1000/1500 M&LtypesmeetClassA ConductedHarmonics EN61000-3-2:2001 ComplianttoClassA Flicker EN61000-3-3:1995+A1:2001 Compliant-d only. max Criteria IMMUNITY Airdischarge 15kV ElectrostaticDischarge EN61000-4-2 Level4 A Contactdischarge 8kV ElectromagneticField EN61000-4-3 Level3 10V/m(testedto12V/m) A Input 4kV Fast/BurstTransient EN61000-4-4 Level4 Outputs 2kV, A Testedat5kHzand100kHz LinetoLine (Differential) 1.1kV SurgeImmunity EN61000-4-5 Level3 A LinetoEarth (CommonMode) 2.2kV ConductedRFImmunity EN61000-4-6 Level3 10V(testedto12V) A PowerFrequencyMagneticField EN61000-4-8 Level4 30AContinuous A A VoltageDips,Variation,Interruptions EN61000-4-11 Class3 Bfor5sinterruptions VoltageFluctuations EN61000-4-14 Class3 For100to240Vnominal A ENVIRONMENT Temperature 0Cto70Coperational,-40to85Cstorage(max12months) Derating 50Cto70Cderateeachoutputby2.5%perC LowTemperatureStart-up -20C Humidity 5-95%RHnoncondensing Shock 3000shocks,eachof10g(16ms)halfsine Vibration 10-200Hz 1.5g Altitude 3,000metresoperational(15,000metresnonoperational) Pollution Degree2,Materialgroup3 IPRating IP10 ISOLATION InputtoOutput Reinforced 4.3kV(dc) OutputtoEarth Operational 500V(dc) InputtoEarth Basic 2.3kV(dc) OutputtoOutput Operational 500V(dc) 2 Alpha Series