1 CC-E 5 web1804162 CC1R5-E CC1R5-E Specifications Nominal Voltage V DC5.0 Voltage Range V DC4.5-9.0 Input Efficiency (typ) (*1) 71 77 80 79 Current (typ) (*1) A 0.372 0.390 0.375 0.380 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Ambient Temperature -40 to +85 Storage Ambient Temperature -40 to +85 Operating Ambient Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/12V models, output voltage can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs (balanced loa means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds. Nominal Voltage V DC12 Voltage Range V DC9.0-18 Input Efficiency (typ) (*1) 73 78 82 81 Current (typ) (*1) A 0.151 0.160 0.152 0.154 Nominal Voltage VDC 3.3 5 12 15 12 15 Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050 Maximum Power (*2) W 1.32 1.5 Maximum Line Regulation (Within input voltage range) mV 20 40 80 Maximum Load Regulation (0-100% load) (*3) mV 40 100 600 Output Temperature Coefficient 80mV 200mV 300mV (Ambient temperature40 C to +50 C) Max Power Total Regulation (max) (*4) 3 5 Maximum Ripple & Noise (typ/max) (*5) mVp-p 40/120 30/120 Voltage Adjustable Range VDC 3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0 Over Current Protection (*6) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Ambient Temperature -40 to +85 Storage Ambient Temperature -40 to +85 Operating Ambient Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity RH 5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 3.2 Mechanical Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6 Note: in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. Note: For 12V/12V models, output voltage can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout. Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) In balanced load for dual outputs (balanced loa means a condition where the +output and -output of load current are equal). (*4) Output voltage includes input change, load change (balanced load), and temperature change. (*5) In 50MHz, Ta=25 C. (*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30 seconds.