*This catalog is for 15W and 25W model. 1 CC-E 5 web19041517 CC15-E CC15-E Specifications Nominal Voltage V DC24 Voltage Range V DC18-36 Input Efficiency (typ) (*1) 89 Current (typ) (*1) A 0.695 0.702 Nominal Voltage VDC 3.3 5 Maximum Current A 4.500 3.000 Maximum Power (*2) W 14.85 15 Maximum Line Regulation(Within input voltage range) mV 65 100 Maximum Load Regulation (0-100% load) mV 120 200 Output Temperature Coefficient 80mV (Ambient temperature -40 t o +50 ) Max Power Total Regulation (max) (*3) +5/-3 Maximum Ripple & Noise (typ/max) (*4) mVp-p 40/120 Voltage Adjustable Range Not available Over Current Protection (*5) Available Function Over Voltage Protection Not available Remote ON/OFF Control Available Operating Ambient Temperature -40 to +85 Storage Ambient Temperature -40 to +85 Operating Ambient Humidity RH 5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.) Environment Storage Ambient Humidity RH 5-95 (the conditions of maximum 38 in wet bulb t emperature and non-condensation should be ensured.) Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each Shock 980m/s (100G), 6ms, 6 directions, 3 times for each, in non-operation Withstand Voltage Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute) Isolation Isolation Resistance Between input terminal and output terminal: 500VDC, 50M min Standards Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO) Weight (typ) g 12.5 Mechanical Size (W x H x D) mm DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1 Note: in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names. Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately. (*1) With nominal input voltage, maximum output current, and Ta=25 C. (*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed. (*3) Output voltage includes input change, load change (balanced load), and temperature change. (*4) In 50MHz, Ta=25 C. (*5) Latch method Resumes by restarting input or resetting remote on/off.