Single Output 150W - 240W CME SERIES 3 UL60601-1 EN60601-1 CSA 22.2 No.601-1, M90 (cUL-certified) Features Conformity to RoHS Directive Medical safety standard (IEC60601-1) approved. This means that, in conformity with EU Directive 2002/95/ Leakage current 0.3mA or less (at 265VAC) EC, lead, cadmium, mercury, hexavalent chromium, and spe- EMI class B approved. cific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. Applications MED Product line up Model CME150-24 CME240P-24 Output voltage 24V 24V Max output current 6.3A 10A Max output power 151.2W 240W Peak output current 7.5A 20A Peak output Power 180W 480W All specifications are subject to change without notice. CME-1CME Specifications MODEL CME150-24 CME240P-24 ITEMS/UNITS Voltage Range (*3) V AC85 - 265 Frequency (*3) Hz 47-63 (*2) Power Factor (100/200VAC)(Typ) 0.99 / 0.95 Input Efficiency (Typ) (*2) % 82 80 Current (100/200VAC)(Typ) (*2) A 2.0 / 1.0 3. 2/ 1.6 C Inrush Current (100/200VAC)(Typ) (*4) A 14 at 100VAC, 28 at 200VAC, Ta=25 , Cold Start Leakage Current (265VAC) (*10) mA Less than 0.3 Less than 0.22 Nominal Voltage VDC 24 Maximum Current A 6.3 10 Maximum Peak Current (*1) A 7.5 20 Maximum Power W 151.2 240 Maximum Peak Power (*1) W 180 480 Maximum Line Regulation (*5,*6) mV 96 Output Maximum Load Regulation (*5,*7) mV 150 192 C Temperature Coefficient Less than 0.02% / Maximum Ripple & Noise 0<Ta<60C (*5) mVp-p 150 240 Maximum Ripple & Noise -10<Ta<0C (*5) mVp-p 180 360 Hold-up Time (Typ) (*2) ms 20 Voltage Adjustable Range (*10) VDC 21.6-26.4 21.6-28.8 Over Current Protection (*8) A 7.87 - 20.5 - Over Voltage Protection (*9) VDC 27.6 - 32.4 30.0 - 35.0 Function Remote ON/OFF Control - Parallel Operation - Series Operation Possible -10 to +60C -10 to +60C (*11) C Operating Temperature (-10 to +50C:100%, +60C:80%) (-10 to +45C:100%, +60C:60%) C C Storage Temperature -30 to +85 Operating Humidity %RH 30 - 90 (No dewdrop) Environment Storage Humidity %RH 10 - 95 (No dewdrop) At no operating, 10-55Hz (Sweep for 1min.) Vibration 19.6m/s Constant, X,Y,Z 1hour each Shock (In package) Less than 196.1m/s Cooling Convection Cooling Input - FG : 2kVAC (20mA), Input - Output : 4kVAC (20mA) Withstand Voltage Isolation Output - FG : 500VAC (100mA) for 1min. C Isolation Resistance More than 100M at 25 and 70%RH, Output - FG : 500VDC Approved by UL60601-1,EN60601-1 Safety Standards (*12) Built to meet UL60950-1,CSA60950-1,EN60950-1, and DENAN Standards PFHC Built to meet EN61000-3-2 (*13) EMI Built to meet EN55011 / EN55022-B, FCC-ClassB, VCCI-B Immunity Built to meet EN61000-4-2, -3, -4, -5, -6, -8, -11 Weight (Typ.) g 500 800 Mechanical Size (WHD) mm 80 x 40 x 208 (Refer to Outline Drawing) 105 x 50 x 242 (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. (*1) Operating period at peak output current is less than 10sec. Input voltage < 95V : Duty < 0.2 Input voltage > 95V : Duty < 0.35 (Average output power and current is less than Maximum output power and current) For peak load derating method, please refer to the instruction manual for details. (*2) At 100/200VAC, Ta=25C and maximum output power. (*3) For cases where conformance to various safety specs (UL,CSA,EN) are required, to be described as100 - 240VAC, 50/60Hz on name plate. (*4) Not applicable for the in-rush current to Noise Filter for less than 0.2ms. (*5) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.(Measure with JEITA RC-9131 probe) (*6) 85 - 265VAC , constant load. (*7) No load - Full load (maximum power), constant input voltage. (*8) Constant current limit and hiccup with automatic recovery. Avoid to operate at overload or dead short condition for more than 30 seconds. (*9) OVP circuit will shut down output, manual reset.(Line recycle) (*10) Measured by the each measuring method of IEC, UL, CSA, EN and DENAN(at 63Hz). (*11) At standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - For other mountings, refer to derating curve. (*12) As for DENAN, built to meet at 100VAC. (*13) No load - Full load (maximum power), constant current and input voltage. CME-2 All specifications are subject to change without notice.