CUS30M & CUS60M Series Speci cations Model CUS30M CUS60M Input Input Voltage range V 85 - 265VAC (3) Input Frequency Hz 47- 63Hz Input Current (115/230VAC) A 0.6 / 0.4 5V: 0.7 / 0.5, 12-48V: 1.2 / 0.8 Inrush Current (typ) (Cold Start) A 30A at 115VAC, 60A at 230VAC Leakage Current uA <250A at 265VAC, 60Hz <200A at 265VAC, 60Hz Touch Current uA 100A at 265VAC, 60Hz 60A at 265VAC, 60Hz Harmonic Compliance - Meets EN61000-3-2 No Load Power Consumption W <0.3W at nominal <0.5W at nominal Hold Up Time (typ) at 115VAC Input ms 20 / 100 Ef ciency - See model selector Average Ef ciency - See model selector. Measured at 25%, 50%, 75% and 100% load conditions Conducted & Radiated EMI - EN55011-B, EN55032-B, FCC Class B Immunity - IEC61000-4-2~8, IEC60601-1-2 Ed4. See immunity table Insulation Class - Construction suitable for Class I or Class II installation Safety Agency Certi cations - EN/IEC/UL/ES/CSA60601-1, EN/IEC/UL/CSA60950-1, EN/IEC/UL/CSA62368-1, IEC60335-1, CE Mark Immunity Test Standard Test Level Criteria Notes ESD EN61000-4-2 3 & 4 A Level 4 contact discharge only Radiated Susceptibility EN61000-4-3 3 A - Electrical Fast Transient Burst EN61000-4-4 3 A - Surge EN61000-4-5 3 & 4 A Level 4 common mode only Conducted Susceptibility EN61000-4-6 3 A - Magnetic elds EN61000-4-8 4 A - Voltage Dips EN61000-4-11 Class 3 B 100 - 120VAC A 200 - 240VAC Short Interruptions EN61000-4-11 Class 3 B - Voltage Dips EN60601-1-2:2015 Class 2 B 100 - 120VAC A 200 - 240VAC Short Interruptions EN60601-1-2:2015 Class 2 B - SEMI F47 Line Dip SEMI F47 - - At input voltages > 200VAC 2 CUS30M & CUS60M Series