CUS600M and CUS600M1 Series Specifications Model CUS600M Input Input Voltage range V 85 - 265Vac (See derating curves) Input Frequency Hz 47 - 63Hz Input Current (115/230Vac) A < 6.0 / 3.0 (600W) Inrush Current at 230Vac (typ) (Cold Start) A <50A Leakage Current uA <200uA at 265Vac 60Hz Touch Current (Enclosure Leakage) uA <100uA Power Factor (115/230Vac) - 0.99 / 0.95 Harmonic Compliance - Meets IEC61000-3-2 Class A No Load Power Consumption W <0.5W at 230Vac (Remote off and no load on 5Vsb) Hold Up Time (typ) at 115Vac Input ms >22ms 400W load, >14ms 600W load Efficiency - Up to 96% (1) Conducted & Radiated EMI (Class I only ) - EN55032/EN55011-B (See installation / instruction manual for conditions) (1) Immunity (Class I only ) - Compliant with EN60601-1-2 2015 (Ed4), see immunity table (1) Insulation Class - Construction suitable for Class I or Class II installation Safety Certifications and Markings - IEC/EN/UL62368-1, 60601-1, ES60601-1 and 60950-1. CE Mark and UKCA Mark Immunity (1) Test Standard Test Level Criteria Notes (the power stated below is total power (main power + fan output)) ESD EN61000-4-2 4 A - Radiated Susceptibility EN61000-4-3 3 A Includes proximity field requirements of EN60601-1-2:2015 Electrical Fast Transient Burst EN61000-4-4 4 A (AC Port, 5kHz and 100kHz) Surge EN61000-4-5 3 A - Conducted Susceptibility EN61000-4-6 3 A - Magnetic fields EN61000-4-8 4 A - 0% for 1/2 cycle A - EN61000-4-11 0% for 1 cycle A/B A up to 330W, B above 330W Class 3 Industrial, 40% for 10/12 cycles A/B A up to 210W, B above 210W incl EN55024 70% for 25/30 cycles A/B A up to 500W, B above 500W (100Vac) 80% for 250/300 cycles A/B A up to 570W, B above 570W 0% for 250/300 cycles B - 0% for 1/2 cycle A - EN61000-4-11 0% for 1 cycle A/B A up to 330W, B above 330W Voltage Dips and Class 3 Industrial, 40% for 10/12 cycles A/B A up to 570W, B above 570W Input Interuptions incl EN55024 70% for 25/30 cycles A - (240Vac) 80% for 250/300 cycles A - 0% for 250/300 cycles B - 0% for 1/2 cycle A Customer to consider essential performance of end equipment EN60601-1-2:2015 0% for 1 cycle A/B A up to 330W, B above 330W (100Vac) 70% for 25/30 cycles A/B A up to 500W, B above 500W 0% for 250/300 cycles B - 0% for 1/2 cycle A Customer to consider essential performance of end equipment EN60601-1-2:2015 0% for 1 cycle A/B A up to 330W, B above 330W (240Vac) 70% for 25/30 cycles A - 0% for 250/300 cycles B - SEMI F47 Line Dip SEMI F47 - - At input voltages > 200Vac 2 CUS600M Series