DT100/150-D Series Specifications Model DT100/150-D Input Input Voltage range Vac 90 - 264 Input Frequency Hz 47 - 63 Input Current (90Vac) A 2.5 Inrush Current at 230Vac (Cold Start) A <150 (25C ambient) Leakage Current (264Vac 60Hz) uA <600 Power Factor - Typically 0.9 at full load, 230VAC (Meets EN61000-3-2) No Load Power Consumption mW <150 Hold Up Time (typ) at 115Vac Input ms 16 Efficiency % >89 Avg. Active Efficiency (1) Conducted & Radiated EMI - EN55032-B, FCC Part 15 Class B Immunity - EN55024 Safety Agency Certifications - UL/CSA/EN/IEC62368-1, UL/CSA/EN/IEC60950-1, CE Mark (LVD, EMC and RoHS) Output Voltage Accuracy % 1 Output Voltage Adjustment - None Switching Frequency (Full Load) kHz 45 - 55 Total Regulation - See Model Selector Table Ripple & Noise (2) - See Model Selector Table Temperature Coefficient %/C 0.05 Minimum Load - No minimum load required Overcurrent Protection % 110 - 160 (Auto-Recovery) Overvoltage Protection - See Model Selector Table (Cycle input power to reset) Short Circuit Protection - Continous - Hiccup Mode (Auto Recovery) Parallel Operation - Not possible Environmental Operating Temperature C -20 to +60, de-rate linearly to 50% load from 40 to 60 Storage Temperature C -20 to +85 Humidity (non condensing) %RH 20 - 90 Cooling - Convection Altitude m 2,000 Withstand Voltage (For 1 minute) Vac Input to Ground 1,500, Input to Output 3,000, Output to Ground 500VDC (3) IP Rating - IPX0 2 Vibration (non-operating) m/s 23.52 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour) 2 Shock m/s <196.1 (20G) Other Weight (Typ) g 780 Size (LxWxH) mm 170 x 85 x 44 Size (LxWxH) Inches 6.70 x 3.35 x 1.73 AC Input Connector - IEC 320-C14 (Accepts IEC 320-C13) DC Output Connector - Kycon KPPx-4P or equivalent Pins 1 & 2: -Vout, Pins 3 & 4: +Vout Cable Length & Thickness - 1050mm 12 to 16V Models: UL2464 16 AWG, 19 to 48V Models: UL2464 18 AWG MTBF (MIL-HNBK, 100% load, 25C) hrs 140,000 Warranty yrs 3 Notes See website for detailed specifications, test methods and installation manual (1) Measured at 25%, 50%, 75% and 100% load conditions (2) Ripple and noise is measured at 20MHz BW. Add 0.1uF ceramic capacitor and 10uF Electrolytic capacitor in parallel across the output (3) Versions available for output to be internally connected to ground. Contact local sales office. 2 DT100/150-D Series