VS-E
SERIES Single Output 50 - 150W
VS150E/A
VS100E/L
VS75E
VS-ESeries
Y
E
VS50E
A
R
S
UL60950-1
EN60950-1(TUV) Low Voltage Directive Electrical Appliance
warranty
CSA60950-1
and Material Safety Law
(Input Voltage 100VAC)
Features
Model name identification method
High efficiency and low standby power.
VS-ESeriesVS-ESeries
VS 50E 5 /
30% Miniaturization from previous models.
Blank : PCB Type
100% load at 50C, suitable for industrial equipment.
Y Y
A : With cover
E E
5 Years warranty (conditions applied)
A A
L : L plate type
R R
S S
UL60950-1 EN60950-1(TUV) Low Voltage Directive UL60950-1 EN60950-1(TUV) Low Voltage Directive
Electrical Appliance warranty Electrical Appliance warranty
CSA60950-1 CSA60950-1 Rated Output Voltage
and Material Safety Law and Material Safety Law
(Input Voltage 100VAC) (Input Voltage 100VAC)
Rated Output Power
Applications
Series Name
Conformity to RoHS Directive
This means that, in conformity with EU Directive 2002/95/
EC, lead, cadmium, mercury, hexavalent chromium, and spe-
cific bromine-based flame retardants, PBB and PBDE, have
not been used, except for exempted applications.
Product line up
Model VS50E VS75E VS100E VS150E
50W 75W 100W 150W
Output Voltage Output Current Efficiency(Typ) Output Current Efficiency(Typ) Output Current Efficiency(Typ) Output Current Efficiency(Typ)
3.3V 10A 80% 15A 80% 20A 80% 30A 80%
5V 10A 85% 15A 85% 20A 85% 30A 86%
12V 4.3A 85% 6.3A 85% 8.5A 85% 12.5A 87%
15V 3.5A 85% 5.0A 85% 7.0A 85% 10.0A 87%
24V 2.5A 85% 3.2A 86% 4.3A 86% 6.3A 87%
48V 1.3A 87% 1.6A 87% 2.2A 87% 3.2A 88%
Option line up
Model VS50E VS75E VS100E VS150E
50W 75W 100W 150W
Output Voltage /A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV
3.3V
5V
12V
15V
24V
48V
All specifications are subject to change without notice. VS-E-VS
50E
VS50E Specifications
MODEL
VS50E-3 VS50E-5 VS50E-12 VS50E-15 VS50E-24 VS50E-48
ITEMS/UNITS
Voltage Range (*2) V AC 85 - 132
Frequency (*2) Hz 47 - 63
% 80 85 87
Efficiency (Typ) (*1)
Input
A 0.9 1.1 1.3
Current (Typ) (*1)
Inrush Current (Typ) (*1)(*11) A 30 at Cold Start
Leakage Current (*8) mA Less than 0.5
VDC 3.3 5 12 15 24 48
Nominal Voltage
A 10 4.3 3.5 2.5 1.3
Maximum Current
Maximum Power W 33.0 50.0 51.6 52.5 60.0 62.4
Maximum Line Regulation (*3)(*4) mV 20 48 60 96 192
mV 40 96 120 150 240
Maximum Load Regulation (*3)(*5)
Output
Less than 0.02% / C
Temperature Coefficient (*3)
Maximum Ripple & Noise(0Ta70C) (*3) mVp-p 120 150 200
Maximum Ripple & Noise(-10Ta<0C) (*3) mVp-p 160 180 240
ms 20
Hold-up Time (Typ) (*1)
VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8
Voltage Adjustable Range (*12)
Over Current Protection (*6) A 10.5 - 4.51 - 3.67 - 2.62 - 1.36 -
Over Voltage Protection (*7) VDC 3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8
Function
Parallel Operation -
Possible
Series Operation
Operating Temperature (*9) C Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)
Storage Temperature C -30 - +85
Operating Humidity %RH 30 - 90 (No dewdrop)
%RH 10 - 95 (No dewdrop)
Storage Humidity
Environment
At no operating, 10 - 55Hz (Sweep for 1min)
Vibration
19.6m/s Constant, X,Y,Z 1hour each.
Shock Less than 196.1m/s
Convection Cooling
Cooling
Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)
Withstand Voltage
Output - FG : 500VAC (20mA) for 1min
Isolation
Isolation Resistance More than 100M at 25C and 70%RH Output - FG : 500VDC
Designed to meet UL60950-1, CSA60950-1, EN60950-1, EN50178(OV II),
Safety Standards
DENAN (Section 2).
Standards EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
Immunity
-5(Level 2,3), -6(Level 3), -8(Level 4), -11
Weight (Typ) g 150
Mechanical
Size (WHD) (*10) mm 50 x 23 x 132 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
(*1) At 100VAC, Ta=25C, nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).
(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.
(*4) 85 - 132VAC, constant load.
(*5) No load-Full load, constant input voltage.
(*6) Fold back current limit with automatic recovery. Avoid to operate at over load or short circuit condition for more than 30seconds.
(*7) OVP circuit will shut the output down, manual reset (Re power on).
(*8) Measured by the each measuring method of UL, CSA, EN and DENAN(at 60Hz), Ta=25C.
(*9) Ratings - Derating at standard mounting. Refer to output derating curve(A239-01-02_).
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*10) Not include lead length on solder side.
(*11) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.
(*12) /FV option is for fixed output voltage.
VS-E- All specifications are subject to change without notice.