HWS50-1500/HD Series Single Output Industrial Power Supplies Features Limited Lifetime Warranty -10 to +71C Operation (-40C start up) Universal Input (85 - 265VAC) Conformally coated pcbs Class 1 Div 2 option (/RYHD suf x) Wide range AC Input Key Market Segments & Applications Speci cations Model HWS50 HWS100 HWS150 HWS300 HWS600 HWS1000 HWS1500 Input Voltage range (47-63Hz) - 85-265VAC or 120-370VDC** 85-265VAC or 120-330VDC** (No DC input for HWS1500) Input Current (Typ) (1) A 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95 4.1 / 2.1 8.1 / 3.9 13.5 / 7 19 / 10 Inrush Current (1) A 14 / 2 20 / 4 Power Factor - Meets EN61000-3-2 Temperature Coef cient - <0.02%/C Overcurrent Protection - >104% Overvoltage Protection V Yes (See table on page 2) Hold Up Time (Typ) ms 20 Leakage Current (60Hz) mA <0.5mA <0.75mA <1.2mA 1.5mA Remote Sense - No Yes Indicator - Green LED = ON Remote On/Off - No Yes (Isolated from output) Parallel operation - No Single wire connection (5 units max) DC Good - No Yes Remote Adjust (PV) - No Yes (3) Operating Temperature C HWS50-150: -10C to +71C, (-10 ~+50C: 100%, +60C: 60%, +71C: 20%) and Derating (operation to HWS300-1500: -10C to +71C, (-10 ~+50C: 100%, derate linearly to 50% load from +50 to +71C) +74C - contact factory) Guaranteed start up at -40C (see speci cation sheets on website for details and derating) Storage Temperature C -40 to +85C Humidity (non condensing) - Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH Cooling - Convection Internal fan Withstand Voltage (2) - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC Vibration (non operating) - MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, gure 514.5C-1) 2 Shock (in packaging) - MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s ) Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark Line Dip - Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI - EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A) Immunity - IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11 Weight (Typ) g 280 450 500 1000 1600 3200 3800 Size (WxHxD) in 1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 5x3.2x9.5 5x3.25x11 Warranty yrs Limited lifetime warranty (See TDK-Lambdas terms & conditions) (1) 100/200VAC input (3) 1-6V program voltage input to adjust output 20-120% (typical) of (2) HWS300-600 2.5kVAC Input to ground nominal. See instruction manual for details & models with this feature. (*) Class 1 Div 2 option (/RYHD suf x (**) Safety certi ed for AC input only HWS50-150/HD Not recommended for new designs, see HWS-A webpage 1-800-526-2324 www.us.tdk-lambda.com/lp/ 63 Disclaimer: us.tdk-lambda.com/lp/legal.htmHWS50-1500/HD Series Output Ratings Adjust Max Peak Max Load Line Ripple Overvoltage Ef ciency 4 1 Model Voltage Range Curr(A) Curr(A) Power(W) Reg(mV) Reg(mV) Noise(mV) (V) (typ)% HWS50-3/HD 3.3V 2.97 - 3.96 10 - 33 40 20 120 4.13-4.95 76/78 HWS100-3/HD 3.3V 2.97 - 3.96 20 - 66 40 20 120 4.13-4.95 78/81 HWS150-3/HD 3.3V 2.97 - 3.96 30 - 99 40 20 120 4.13-4.95 78/81 HWS300-3/HD 3.3V 2.64 - 3.96 60 - 198 30 20 120 4.13-4.95 74/77 HWS600-3/HD 3.3V 2.64 - 3.96 120 - 396 30 20 120 4.13-4.95 75/78 HWS1000-3/HD 3.3V 2.64 - 3.96 200 - 660 40 20 120 4.12-4.62 71/73 HWS1500-3/HD 3.3V 2.64 - 3.96 300 - 990 60 36 150 4.12-4.62 72/75 HWS50-5/HD 5V 4.0 - 6.0 10 - 50 40 20 120 6.25-7.25 82/84 HWS100-5/HD 5V 4.0 - 6.0 20 - 100 40 20 120 6.25-7.25 83/86 HWS150-5/HD 5V 4.0 - 6.0 30 - 150 40 20 120 6.25-7.25 83/86 HWS300-5/HD 5V 4.0 - 6.0 60 - 300 30 20 120 6.25-7.25 79/82 HWS600-5/HD 5V 4.0 - 6.0 120 - 600 30 20 120 6.25-7.25 80/83 HWS1000-5/HD 5V 4.0 - 6.0 200 - 1000 40 20 120 6.25-7 76/78 HWS1500-5/HD 5V 4.0 - 6.0 300 - 1500 60 36 150 6.25-7 77/81 HWS1000-6/HD 6V 4.8 - 7.2 167 - 1002 60 36 150 7.5-8.4 79/81 HWS1000-7/HD 7.5V 6.0 - 9.0 134 160 1005 60 36 150 9.37-10.5 80/82 HWS50-12/HD 12V 9.6 - 14.4 4.3 - 51.6 96 48 150 15-17.4 81/83 HWS100-12/HD 12V 9.6 - 14.4 8.5 - 102 96 48 150 15-17.4 83/86 HWS150-12/HD 12V 9.6 - 14.4 13 - 156 96 48 150 15-17.4 83/86 HWS300-12/HD 12V 9.6 - 14.4 27 - 324 72 48 150 15-17.4 80/83 HWS600-12/HD 12V 9.6 - 14.4 53 - 636 72 48 150 15-17.4 80/83 HWS1000-12/HD 12V 9.6 - 14.4 88 100 1056 100 48 150 15-17.4 82/85 HWS1500-12/HD 12V 9.6 - 14.4 125 - 1500 72 48 150 15-17.4 82/85 HWS50-15/HD 15V 12.0 - 18.0 3.5 - 52.5 120 60 150 18.8-21.8 81/83 HWS100-15/HD 15V 12.0 - 18.0 7 - 105 120 60 150 18.8-21.8 83/86 HWS150-15/HD 15V 12.0 - 18.0 10 - 150 120 60 150 18.8-21.8 83/86 HWS300-15/HD 15V 12.0 - 18.0 22 - 330 90 60 150 18.8-21.8 80/83 HWS600-15/HD 15V 12.0 - 18.0 43 - 645 90 60 150 18.8-21.8 81/84 HWS1000-15/HD 15V 12.0 - 18.0 70 80 1500 120 60 150 18.7-21.8 83/85 HWS1500-15/HD 15V 12.0 - 18.0 100 - 1500 90 60 150 18.7-21.8 83/87 HWS50-24/HD 24V 19.2 - 28.8 2.2 - 52.8 192 96 150 30-34.8 82/84 HWS100-24/HD 24V 19.2 - 28.8 4.5 - 108 192 96 150 30-34.8 84/87 HWS150-24/HD 24V 19.2 - 28.8 6.5 - 156 192 96 150 30-34.8 85/88 HWS300-24/HD 24V 19.2 - 28.8 14 16.5 336 144 96 150 30-34.8 82/85 HWS600-24/HD 24V 19.2 - 28.8 27 31 648 144 96 150 30-34.8 82/85 HWS1000-24/HD 24V 19.2 - 28.8 46 58.5 1104 150 96 150 30-34.8 85/87 HWS1500-24/HD 24V 19.2 - 28.8 65/70 (1) 105 1560 144 96 200 30-34.8 84/88 HWS1000-36/HD 36V 28.8 - 43.2 30.7 39 1104 150 144 200 45-49.7 85/88 HWS1500-36/HD 36V 28.8 - 43.2 42/46.5(2) 70 1512 150 144 200 45-49.7 84/88 HWS50-48/HD 48V 38.4 - 52.8 1.1 - 52.8 384 192 200 55.2-64.8 83/85 HWS100-48/HD 48V 38.4 - 52.8 2.1 - 100.8 384 192 200 55.2-64.8 84/87 HWS150-48/HD 48V 38.4 - 52.8 3.3 - 158.4 384 192 200 55.2-64.8 85/88 HWS300-48/HD 48V 38.4 - 52.8 7 - 336 288 192 350 55.2-64.8 82/85 HWS600-48/HD 48V 38.4 - 52.8 13 - 624 288 192 350 55.2-64.8 83/86 HWS1000-48/HD 48V 38.4 - 52.8 28 29.2 1104 300 192 200 55.2-60 86/88 HWS1500-48/HD 48V 38.4 - 52.8 32 - 1536 288 192 200 55.2-64.8 86/90 HWS1000-60/HD 60V 48.0 - 66.0 18.4 23.4 1104 360 240 400 69-75 85/88 (4) 200-265VAC Input, 10s maximum on time, 35% duty cycle Options Other Industrial Products Suf x Description LZSA 500W to 1500W Single output Blank No Cover (HWS50-150 Only) DPP, DLP, DSP 10W to 960W DIN Rail Mount HWS300-1500 the cover is tted as standard PFE 300 to 1000W AC-DC Power Models /HDA The cover option for HWS50-150 is special order only HWS300-1500 the cover is tted as standard /RYHD ISA 12.12.01 (UL1604) - Class 1 Div 2 with dry contact relay For Additional Information, please visit DC Good signal (300W, 600W and 1500W 24V output models us.tdk-lambda.com/lp/products/hws-series.htm only, no remote on/off function.) HWS50-150/HD Not recommended for new designs, see HWS-A webpage 1-800-526-2324 www.us.tdk-lambda.com/lp/ 64 Revision B4.4: Sept 2014