HWS300-1500 Series 300-1500W Single Output Industrial Power Supplies Features Limited Lifetime Warranty UL508 approved SEMI F47 Compliant (high line AC) Universal Input (85 - 265VAC) High E ciency Class 1 Div 2 option (/RY su x) Wide Range AC Input Key Market Segments & Applications Speci cations Model HWS300 HWS600 HWS1000 HWS1500 Input Voltage range (47-63Hz) - 85 - 265VAC or 120 - 330VDC (6)** Input Current (Typ) (1) A 5V: 3.8/1.9 5V: 7.5/3.6 3.3V: 9.6/5.0 3.3V: 15.0/8.0 12-48V: 4.2/2.1 12-48V: 8.1/3.9 5-60V: 13.5/7.0 5-60V: 19.5/10.0 Inrush Current (1) A 20 / 40 Power Factor - Meets EN61000-3-2 Temperature Coe cient - <0.02%/C Overcurrent Protection - >105% (>101% of peak current for peak current capable models) Overvoltage Protection V See table on page 2 (Recycle AC or remote on/o to reset) Hold Up Time (Typ) ms 20 Leakage Curr. (at 240VAC, 60Hz) mA <0.75mA <1.2mA <1.5mA Remote Sense - Yes Indicator - Green LED = ON Remote on/o - Yes (Isolated from output) Parallel operation - Single wire connection (up to 5 units) DC Good - Yes Remote Adjust (PV) - External voltage adjusts output, see options table Operating Temperature - -10C to +70C, derate linearly to 50% load from 50C to 70C (2, 3) Storage Temperature C -30 to +85C Humidity (non condensing) - Operating: 10 - 90%RH, Non operating 10 - 95%RH Cooling - Internal fan Withstand Voltage (4) - Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Certi cations (5) - IEC/EN/UL/CSA 60950-1 and 62368-1, EN50178, UL508, CE Mark Line Dips - SEMI-F47 (200VAC input) Conducted & Radiated EMI - EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) Immunity - IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 Weight (Typ) g 1,000 1,600 3,200 3.3-7.5V: 4000 12V+: 3800 Size (WxHxD) in 2.4 x 3.23 x 6.5 3.94 x 3.23 x 6.5 5 x 3.25 x 9.45 5 x 3.25 x 11 MTBF - Telcordia SR-332 issue 3*** hours 2,145,809 1,998,996 1,087,031 1,152,309 Warranty yrs Limited lifetime warranty (See TDK-Lambdas terms and conditions) (1) 100/200VAC (5) UL60601-1, EN60601-1, see options. (2) HWS start up -20C. (-40C see options table) UL508 HWS300/600 5V, 12V, 24V & 48V models (3) HWS1000/1500 with 85VAC input: See installation manual (6) Not on HWS1500/ME, /HD or /RY versions (4) 2kVAC HWS1000/1500 Input to ground (*) Class 1 Div 2 option (/RY su x) HWS1000: -10 to +71C. HWS1000-5, HWS1500-3, -5 derate linearly above 40C (**) Safety certi ed for AC input only (***) 24V output model, 25C ambient, full load, 230VAC inputHWS300-1500 Series Output Ratings Adjust Max Peak Max. Load Line Ripple Over- E . Voltage Range Curr. Curr. Pwr. Reg Reg Noise voltage typ Model V V(3) A A(2) W mV mV mV V % (1) HWS300-3 3.3V 2.64 - 3.96 60 - 198 30 20 120 4.13 - 4.95 74/77 HWS600-3 3.3V 2.64 - 3.96 120 - 396 30 20 120 4.13 - 4.95 75/78 HWS1000-3 3.3V 2.64 - 3.96 200 - 660 40 20 120 4.13 - 4.62 71/73 HWS1500-3 3.3V 2.64 - 3.96 300 - 990 60 36 150 4.12 - 4.62 72/75 HWS300-5 5V 4 - 6 60 - 300 30 20 120 6.25 -7.25 79/82 HWS600-5 5V 4 - 6 120 - 600 30 20 120 6.25 -7.25 80/83 HWS1000-5 5V 4 - 6 200 - 1000 40 20 120 6.25 - 7.0 76/78 HWS1500-5 5V 4 - 6 300 - 1500 60 36 150 6.25 - 7.0 77/81 HWS1000-6 6V 4.8 - 7.2 167 - 1002 60 36 150 7.5 - 8.4 79/81 HWS1500-6 6V 4.8 - 7.2 250 300 1500 60 36 150 7.5 - 8.4 79/82 HWS1000-7 7.5V 6 - 9V 134 160 1005 60 36 150 9.38 - 10.5 80/82 HWS1500-7 7.5V 6 - 9V 200 240 1500 60 40 150 9.37 - 10.5 81/83 HWS300-12 12V 9.6 - 14.4 27 - 324 96 48 120 15 - 17.4 80/83 HWS600-12 12V 9.6 - 14.4 53 - 648 96 48 120 15 - 17.4 80/83 HWS1000-12 12V 9.6 - 14.4 88 100 1056 100 48 150 15 - 17.4 83/85 HWS1500-12 12V 9.6 - 14.4 125 - 1500 72 48 150 15 - 17.4 82/85 HWS300-15 15V 12 - 18 22 - 330 120 60 150 18.8 - 21.8 82/85 HWS600-15 15V 12 - 18 43 - 645 120 60 150 18.8 - 21.8 82/85 HWS1000-15 15V 12 - 18 70 80 1050 120 60 150 18.8 - 21.8 83/85 HWS1500-15 15V 12 - 18 100 - 1500 90 60 150 18.7 - 21.8 83/87 HWS300-24 24V 19.2 - 28.8 14 16.5 336 192 96 150 30 - 34.8 82/85 HWS600-24 24V 19.2 - 28.8 27 31 648 192 96 150 30 - 34.8 82/85 HWS1000-24 24V 19.2 - 28.8 44 50 1056 150 96 150 30 - 34.8 85/87 HWS1500-24 24V 19.2 - 28.8 65/70 (1) 105 1560 144 96 200 30 - 34.8 84/88 HWS1000-36 36V 28.8 - 43.2 29.3 33.3 1055 150 144 200 45 - 49.7 85/88 HWS1500-36 36V 28.8 - 43.2 42/46.5 (1) 70 1512 150 144 200 45 - 49.7 84/88 HWS300-48 48V 38.4 - 52.8 7 - 336 384 192 200 55.2 - 64.8 82/85 HWS600-48 48V 38.4 - 52.8 13 - 624 384 192 200 55.2 - 64.8 82/85 HWS1000-48 48V 38.4 - 52.8 22 25 1056 300 192 200 55.2 - 64.8 86/88 HWS1500-48 48V 38.4 - 52.8 32 - 1536 288 192 200 55.2 - 64.8 86/90 HWS1000-60 60V 48 - 66 17.6 20 1056 360 240 400 69 - 75 85/88 HWS1500-60 60V 48 - 66 25.6/28 (1) 42 1536 360 240 400 69 - 75 86/90 Notes (1) 100/200VAC (2) 200-265VAC Input, 10s maximum on time with 35% duty cycle (3) Use program input (PV) to adjust from 20-120% of nominal (20-110% for 48V & 60V models) Options Other Industrial Products Su x Description HWS 15W to 150W single output Blank HWS300-1500 the cover is tted as standard LZSA 500W to 1500W Single output /A Not Applicable SWS 50W to 1000W, low cost HWS300-1500 the cover is tted as standard DPP, DLP & DSP 10W to 480W DIN Rail Mount /PV HWS300, 600 (Standard on HWS1000 & 1500): 1-6V program voltage input to adjust output 20-120% of nominal (20-110% for 48V) (12V-48V models only) /HD See HWS50-1500/HD Datasheet for details.-40 to +71(74)C For Additional Information, please visit operation, conformally coated PCBs