HWS Series Datasheets HWS Series Datasheets HWS300-1500 Series HWS-1800T Series Pages 1 2 Pages 3 4 HWS300-1500 Series 300-1500W Single Output Industrial Power Supplies Features Limited Lifetime Warranty UL508 approved SEMI F47 Compliant (high line AC) Universal Input (85 - 265VAC) High E ciency Class 1 Div 2 option (/RY su x) Wide Range AC Input Key Market Segments & Applications Speci cations Model HWS300 HWS600 HWS1000 HWS1500 Input Voltage range (47-63Hz) - 85 - 265VAC or 120 - 330VDC (6)** Input Current (Typ) (1) A 5V: 3.8/1.9 5V: 7.5/3.6 3.3V: 9.6/5.0 3.3V: 15.0/8.0 12-48V: 4.2/2.1 12-48V: 8.1/3.9 5-60V: 13.5/7.0 5-60V: 19.5/10.0 Inrush Current (1) A 20 / 40 Power Factor - Meets EN61000-3-2 Temperature Coe cient - <0.02%/C Overcurrent Protection - >105% (>101% of peak current for peak current capable models) Overvoltage Protection V See table on page 2 (Recycle AC or remote on/o to reset) Hold Up Time (Typ) ms 20 Leakage Curr. (at 240VAC, 60Hz) mA <0.75mA <1.2mA <1.5mA Remote Sense - Yes Indicator - Green LED = ON Remote on/o - Yes (Isolated from output) Parallel operation - Single wire connection (up to 5 units) DC Good - Yes Remote Adjust (PV) - External voltage adjusts output, see options table Operating Temperature - -10C to +70C, derate linearly to 50% load from 50C to 70C (2, 3) Storage Temperature C -30 to +85C Humidity (non condensing) - Operating: 10 - 90%RH, Non operating 10 - 95%RH Cooling - Internal fan Withstand Voltage (4) - Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Certi cations (5) - IEC/EN/UL/CSA 60950-1 and 62368-1, EN50178, UL508, CE Mark Line Dips - SEMI-F47 (200VAC input) Conducted & Radiated EMI - EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) Immunity - IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 Weight (Typ) g 1,000 1,600 3,200 3.3-7.5V: 4000 12V+: 3800 Size (WxHxD) in 2.4 x 3.23 x 6.5 3.94 x 3.23 x 6.5 5 x 3.25 x 9.45 5 x 3.25 x 11 MTBF - Telcordia SR-332 issue 3*** hours 2,145,809 1,998,996 1,087,031 1,152,309 Warranty yrs Limited lifetime warranty (See TDK-Lambdas terms and conditions) (1) 100/200VAC (5) UL60601-1, EN60601-1, see options. (2) HWS start up -20C. (-40C see options table) UL508 HWS300/600 5V, 12V, 24V & 48V models (3) HWS1000/1500 with 85VAC input: See installation manual (6) Not on HWS1500/ME, /HD or /RY versions (4) 2kVAC HWS1000/1500 Input to ground (*) Class 1 Div 2 option (/RY su x) HWS1000: -10 to +71C. HWS1000-5, HWS1500-3, -5 derate linearly above 40C (**) Safety certi ed for AC input only (***) 24V output model, 25C ambient, full load, 230VAC input 1