HWS/ME Series Single Output Medical Power Supplies Features Limited Lifetime Warranty 2 Medical Certi cations Universal Input (85 - 265VAC) High E ciency Broad 30W to 1500W product range Key Market Segments & Applications Speci cations HWS30A HWS100A HWS1000 Model HWS50A HWS150A HWS300 HWS600 HWS1500 Input Voltage range (47-63Hz) - 85 - 265VAC (47 - 63Hz) 85 - 265VAC (47 - 63Hz) 85 - 265VAC or 120 - 370VDC* or 120 - 330VDC* (47 - 63Hz) Input Current (Typ) (1) A 0.65 / 0.4 1.3 / 0.65 13.5 / 7.0 0.65 / 0.35 1.9 / 0.95 4.1 / 2.1 8.1 / 3.9 19 / 10 Inrush Current (1) A 14 / 28 20 / 40 Power Factor / Flicker - Meets EN61000-3-2, EN61000-3-3 o Temperature Coe cient - <0.02%/ C Overcurrent Protection - >104% Overvoltage Protection V yes (See table on page 2) Hold Up Time (Typ) ms 20 Leakage Current (60Hz) mA <0.5mA Remote Sense - No Yes Indicator - Green LED = ON Remote On/O - No Yes (Isolated from output) Parallel operation - No Single wire connection (5 units max) DC Good - No Yes Voltage Programming No Yes Operating Temperature C HWS30A-150A: -10C to +70C, (See website for derating above 50C) and Derating HWS300-1500: -10C to +70C, (-10 - +50C: 100%, derate linearly to 50% load from +50 to +70C) Storage Temperature C -30 to +85C Humidity (non condensing) - Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH Cooling Convection Internal fan Withstand Voltage (3) - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC, Output to Remote On/O 100VAC for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/o 100VDC 2 Vibration (non operating) - 10 - 55Hz (1 min sweep), 19.6m/s constant, X, Y, Z axis, one hour each 2 Shock (in packaging) - < 196.1m/s Safety Agency Certi cations (2) - ES60601-1, EN60601, CSA-C22.2 No601.1-M90 (C-UL) (basic insulation), CE Mark Line Dip - Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI - EN55011 / EN55032-B, FCC-B, VCCI-B (HWS600, 1000 & 1500 Class A) Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2, IEC60601-1-2 Ed.4*** Weight (Typ) g 200 420 3200 260 470 1000 1600 3800 Size (WxHxD) in 1.04x3.23x3.74 1.1x3.23x6.3 4.98x3.23x9.45 1.04x3.23x4.72 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 4.98x3.23x11.02 8,169,868 2,963,512 1,087,031 MTBF - Telcordia SR-332 issue 3** hours 3,726,622 2,676,081 2,145,809 1,998,996 1,152,309 Warranty yrs Limited lifetime warranty (See website for terms & conditions) (1) 100/200VAC input * Safety certi ed for AC input only (2) See clause 19.5DV.2 of UL60601 for equipment in proximity of patient ** 24V output model, 25C ambient, full load, 230VAC input (3) HWS300-600 2.5kVAC Input to ground *** HWS30A-150A/ME only (See immunity data on website) 1-800-526-2324 www.us.tdk-lambda.com/lp/ 63 Disclaimer: us.tdk-lambda.com/lp/legal.htmHWS/ME Series Output Ratings Adjust Max Max Load Line Ripple Overvoltage E ciency (1) Model Voltage Range Current (A) Power (W) Reg(mV) Reg(mV) Noise(mV) (V) (typ) % HWS30A-5/ME 5V 4.0 - 6.0 6 30 40 20 120 6.25-7.25 80/82 HWS50A-5/ME 5V 4.0 - 6.0 10 50 40 20 120 6.25-7.25 82/84 HWS100A-5/ME 5V 4.0 - 6.0 20 100 40 20 120 6.25-7.25 84/86 HWS150A-5/ME 5V 4.0 - 6.0 30 150 40 20 120 6.25-7.25 85/87 HWS600-5/ME 5V 4.0 - 6.0 120 600 30 20 120 6.25-7.25 80/83 HWS30A-12/ME 12V 9.6 - 14.4 2.5 30 96 48 150 15-17.4 84/86 HWS50A-12/ME 12V 9.6 - 14.4 4.3 51.6 96 48 150 15-17.4 83/85 HWS100A-12/ME 12V 9.6 - 14.4 8.5 102 96 48 150 15-17.4 86/88 HWS150A-12/ME 12V 9.6 - 14.4 13 156 96 48 150 15-17.4 85/88 HWS300-12/ME 12V 9.6 - 14.4 27 324 72 48 150 15-17.4 80/83 HWS600-12/ME 12V 9.6 - 14.4 53 636 72 48 150 15-17.4 80/83 HWS30A-15/ME 15V 12.0 - 18.0 2 30 120 60 150 18.8-21.8 85/87 HWS50A-15/ME 15V 12.0 - 18.0 3.5 52.5 120 60 150 18.8-21.8 83/86 HWS100A-15/ME 15V 12.0 - 18.0 7 105 120 60 150 18.8-21.8 86/88 HWS150A-15/ME 15V 12.0 - 18.0 10 150 120 60 150 18.8-21.8 86/89 HWS300-15/ME 15V 12.0 - 18.0 22 330 90 60 150 18.8-21.8 80/83 HWS600-15/ME 15V 12.0 - 18.0 43 645 90 60 150 18.8-21.8 81/84 HWS30A-24/ME 24V 19.2 - 28.8 1.3 31.2 150 96 150 30-34.8 86/88 HWS50A-24/ME 24V 19.2 - 28.8 2.2 52.8 150 96 150 30-34.8 84/87 HWS100A-24/ME 24V 19.2 - 28.8 4.5 108 150 96 150 30-34.8 87/89 HWS150A-24/ME 24V 19.2 - 28.8 6.5 156 150 96 150 30-34.8 88/90 (4) (4) HWS300-24/ME 24V 19.2 - 28.8 14 (16.5 pk) 336, (396 pk ) 144 96 150 30-34.8 82/85 (4) (4) HWS600-24/ME 24V 19.2 - 28.8 27 (31 pk) 648, (744 pk ) 144 96 150 30-34.8 82/85 HWS1000-24/ME 24V 19.2 - 28.8 (5) (4) (4) 4.8 - 28.8 46 (58.5 pk) 1104, (1404 pk ) 150 96 150 30-34.8 85/87 HWS1500-24/ME 24V 19.2 - 28.8 (5) (1) (4) (1), (4) 4.8 - 28.8 65/70 (105 pk) 1560/1680 (2520 pk ) 144 96 200 30-34.8 84/88 HWS1000-36/ME 36V 28.8 - 43.2 (5) (4) (4) 7.2 - 43.2 30.7 (39 pk) 1104, (1404 pk ) 150 144 200 45-49.7 85/88 HWS1500-36/ME 36V 28.8 - 43.2 (5) (1) (4) (1) (4) 7.2 - 43.2 42/46.5 (70 pk) 1512/1674 , (2520 pk ) 150 144 200 45-49.7 84/88 HWS30A-48/ME 48V 38.4 - 52.8 0.65 31.2 240 192 200 55.2-64.8 86/87 HWS50A-48/ME 48V 38.4 - 52.8 1.1 52.8 240 192 200 55.2-64.8 84/86 HWS100A-48/ME 48V 38.4 - 52.8 2.1 100.8 240 192 200 55.2-64.8 88/90 HWS150A-48/ME 48V 38.4 - 52.8 3.3 158.4 240 192 200 55.2-64.8 89/91 HWS300-48/ME 48V 38.4 - 52.8 7 336 288 192 350 55.2-64.8 82/85 HWS600-48/ME 48V 38.4 - 52.8 13 624 288 192 350 55.2-64.8 83/86 HWS1000-48/ME 48V 38.4 - 52.8 (5) (4) (4) 9.6 - 52.8 23 (29.2 pk) 1104, (1404 pk ) 300 192 200 55.2-60.8 86/88 HWS1500-48/ME 48V 38.4 - 52.8 (5) 9.6 - 52.8 32 1536 288 192 200 55.2-64.8 86/90 (1) 100/200VAC input (4) Peak load at 200VAC input for 10s maximum on time, 35% duty cycle (2) See clause 19.5DV.2 of UL60601 for equipment in proximity of patient (5) Using voltage programming input - see installation manual for details (3) HWS300-600 2.5kVAC Input to ground Options Other Medical Products Su x Description NV Series 175 to 700W single & multiple output /ME No Cover (HWS30A-150A/ME Only) Vega Series 450 to 900W single & multiple output HWS300-1500/ME the cover is always tted Alpha Series 1000W single and multiple output /MEA With Cover (HWS30A-150A/ME only) For Additional Information, please visit us.tdk-lambda.com/lp/products/hwsa-series.htm 1-800-526-2324 www.us.tdk-lambda.com/lp/ 64 Revision B3: Dec 2017