NEMIC-LAMBDA JWS 150 SPECIFICATIONS A160-01-01A MODEL JWS150 JWS150 JWS150 JWS150 JWS150 JWS150 -3 -5 -12 -15 -24 -48 ITEMS 1 Nominal Output Voltage V 3.3 5 12 15 24 48 30 30 13 10 6.5 3.3 2 Maximum Output Current A 3 Maximum Output Power W 99 150 156 150 156 158.4 67 75 77 78 80 80 4 Efficiency (Typ) (*1) % 5 Input Voltage Range (*2) - 85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC 1.5/0.75 2.0/1.0 6 Input Current (100/200VAC)(Typ) (*1) A 7 Inrush Current(Typ) - 25A at 100VAC, 50A at 200VAC, Ta=25C, Cold Start Built to meet EN61000-3-2 8 PFHC - 9 Power Factor (100/200VAC)(Typ) (*1) - 0.99/0.95 2.85~3.63 4.5~5.5 10.8~13.2 13.5~16.5 21.6~26.4 43.2~52.8 10 Output Voltage Range V 11 Maximum Ripple & Noise 0 ~ +60C mV 120 120 150 150 150 200 160 160 180 180 180 240 (*3) -10 ~ 0C mV 12 Maximum Line Regulation (*4) mV 20 20 48 60 96 192 40 40 96 120 150 240 13 Maximum Load Regulation (*5) mV 14 Temperature Coefficient - Less than 0.02%/C 31.5 ~ 31.5 ~ 13.65 ~ 10.5 ~ 6.82 ~ 3.46 ~ 15 Over Current Protection (*6) A 16 Over Voltage Protection (*7) V 3.79~4.95 5.75~6.75 13.8~16.2 17.3~20.3 27.6~32.4 55.2~64.8 20ms 17 Hold-up Time (Typ) (*8) - 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC 18 Leakage Current (*9) - 19 Remote Sensing - Possible - 20 Parallel Operation - 21 Series Operation - Possible -10 ~+60C ( -10 ~+50C:100%, +60C:60%) 22 Operating Temperature (*10) - 23 Operating Humidity - 30 ~ 90%RH (No dewdrop) -30 ~ +85C 24 Storage Temperature - 25 Storage Humidity - 10 ~ 95%RH (No dewdrop) Convection Cooling 26 Cooling - 27 Withstand Voltage - Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC (100mA) for 1min 28 Isolation Resistance - More than 100M at 25C and 70%RH Output - FG ... 500VDC At no operating, 10 ~ 55Hz (Sweep for 1min) 29 Vibration - 2 19.6m/s Constant, X,Y,Z 1hour each. 2 30 Shock (In package) - Less than 196.1m/s 31 Safety (*11) - Approved by UL1950, CSA950, EN60950,VDE0160. Built to meet DENTORI. 32 Conducted Emission - Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B. 33 Radiated Emission - 34 Weight(Typ.) g 850 65 x 92 x 198 ( Refer to Outline Drawing ) 35 Size (W x H x D) mm *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 100/200VAC, Ta=25C and maximum output power. *2. For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 ~ 240VAC(50/60Hz). *3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz. *4. 85 ~ 265VAC , constant load. *5. No load-Full load, constant input voltage. *6. Constant current limit with automatic recovery. *7. OVP circuit will shut down output, manual reset (Line recycle). *8. At 100/200VAC nominal output voltage and maximum output current. *9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz). *10. Ratings - Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - As for other mountings, refer to derating curve (A160-01-02 ). NEMIC-LAMBDA JWS 150 OUTPUT DERATING A160-01-02 LOAD(%) Ta(C) MOUNTING A MOUNTING B MOUNTING C -10 ~+40 100 100 100 45 100 80 80 50 100 60 60 55 80 - - 60 60 - - OUTPUT DERATING CURVE 100 80 MOUNTING A MOUNTING B,C 60 40 20 0 -10 0 10 20 30 40 50 60 Ta(C) MOUNTING A MOUNTING B MOUNTING C DON T USE DON T USE (STANDARD MOUNTING) LOAD(%)