5 Year Warranty Power Factor Corrected Approved to VDE01 60 Machinery Directive Universal Input (85 265VAC) Key Market Segments & Applications Factory Automation: Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots JWT Series Test & Measurement: Burn-in & Test, Triple Output Automated Test, Instrumentation, Industrial Power Supplies Measurement, Detection JWT Features and Benefits Features Benefits VDE01 60 Approved No Additional Approvals Needed 5 Year Warranty Lower Cost of Ownership Power Factor Corrected Supports Global Use Level B EMI Assists Systems Compliance Specifications MODEL JWT75 JWT100 ITEMS Max Output Power W 75 100 Efficiency (Typ) % 72 Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 330VDC Input Current Typ A 1.2 / 0.6 1.4 / 0.7 Inrush Current A 14A at 100VAC, 28A at 200VAC input Power Factor - Meets EN61000-3-2 Output Voltage Accuracy - V1 variable, V2 & V3 +/-5% Temperature Coefficient - V1 & V2 <0.02%/C, V3 <0.03%/C Overcurrent Protection - >105% Overvoltage Protection V Main output only: 5.7 - 7V Hold Up Time (Typ) ms 20 Leakage Current - 0.75mA Max, 0.44mA typical at 230VAC Operating Temperature - -10C to +65C, derate linearly to 50% load from 50C to 65C -10C to +50C, derate linearly to 60% load from 40C to 50C with cover Storage Temperature C -30 to +85 Humidity - 30 - 90% RH (operating), 10 - 95% RH (non operating) Cooling - Convection Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 196m/s constant X, Y, Z 1 hour 2 Shock - <196.1m/s Safety Agency Approvals - IEC/UL/CSA/EN62368-1, 60950-1, CE Mark Conducted & Radiated EMI - EN55011 / EN55022-B, FCC Class B, VCCI-B Weight (Typ) g 600 720 Size (WxHxD) mm 42 x 92 x 188 48 x 92 x 203 Warranty - 5 Years Note: See Installation Manual for full details, test methods of parameters and application notes. 1 JWT SeriesModel Selector Adjust. Min Max Load Reg Line Reg Ripple & Model Output Voltage Range Current (A) Current (A) (mV) (mV) Noise (mV) JWT75-522/A V1 +5V 5 - 5.25 0.8 8 40 20 120 V2 +12V -0 4 100 48 150 V3 -12V -0 0.5 150 48 150 JWT75-5FF/A V1 +5V 5 - 5.25 0.8 8 40 20 120 V2 +15V -0 3.2 120 60 150 V3 -15V -0 0.5 150 60 150 JWT75-525/A V1 +5V 5 - 5.25 0.8 8 40 20 120 V2 +12V -0 4 100 48 150 V3 -5V -0 0.5 100 20 150 JWT100-522/A V1 +5V 5 - 5.25 1.3 13 40 20 120 V2 +12V -0 5.5 100 48 150 V3 -12V -0 1 150 48 150 JWT100-5FF/A V1 +5V 5 - 5.25 1.3 13 40 20 120 V2 +15V -0 4.5 120 60 150 V3 -15V -0 1 150 60 150 JWT100-525/A V1 +5V 5 - 5.25 1.3 13 40 20 120 V2 +12V -0 5.5 100 48 150 V3 -5V -0 1 100 20 150 Options Suffix Description Blank Screw terminals, no cover /A Screw terminals, cover (Standard US stock item) /R Remote On / Off Example JWT75-525/RC Outline Drawing JWT Series 2 JWT Series W H FRONT VIEW H (BOTH SIDES) SIDE VIEW W MOUNTING SURFACE D