MC13 Series
6A to 30A, 500VAC 3 Phase EMI Filters
Features
u Industry Standard Size
u DIN Rail Mountable
Speci cations
Model MC1306DIN MC1310DIN MC1320DIN MC1330DIN
Rated Voltage (AC) V 500 (50/60Hz) Three Phase
Rated Current (AC) (1) A 6 10 20 30
Test Voltage V 2000 (100mA) @ 25C, 70%RH
(terminal to baseplate, AC 1 min.)
Isolation Resistance M 100M min. @ 25C, 70%RH
(terminal to baseplate, 500VDC)
Leakage Current (500V, 60Hz) mA 5.0 max
DC Resistance (three lines) M 90 max 68 max 23 max 11 max
Temperature Rise C 30 max
Operating Temperature C -25 to +85C
Operating Humidity % 30% to 95% RH (non-condensing)
Storage Temperature C -40 to +85C
Storage Humidity % 10% to 95% RH (non-condensing)
2
Vibration - 10~55Hz, (Sweep for 1 min) 9.8m/s , X, Y, Z axes, 1 hour each
Safety Standard - Approved to UL1283, CSA std.C22.2No.8(CUL), EN133200(VDE)
Size mm 135.5 (L) x 59.4 (H) x 63 (W)
Weight (Typ.) g 600
Note (1) Value for Ta < 50C.
For Ta > 50C derate according to the derating curve.
1-800-526-2324 www.us.tdk-lambda.com/lp/ 11 Disclaimer: us.tdk-lambda.com/lp/legal.htmMC13 Series
Outline Drawing Derating
120
100
80
60
40
20
0
25 40 50 60 70 80 90
Typ. Attenuation, Symmetrical Typ. Attenuation, Asymmetrical
MC1306 MC1310 MC1320 MC1330 MC1306 MC1310 MC1320 MC1330
0
0
20
20
40
40
60
60
80
80
100
100
120
120
0.1 1 10 100
0.1 1 10 100
Frequency (MHz)
Frequency (MHz)
For Additional Information, please visit
us.tdk-lambda.com/lp/products/mc13-series.htm
Last time buy - June 1, 2014
1-800-526-2324 www.us.tdk-lambda.com/lp/ 12 Revision A3: May 2013
Attenuation (dB)
Current (%)
Attenuation (dB)