NV-350 / NV-700 2. Select Output Modules from the Module Tables below ensuring that no more that 6 slots (NV-350) or 8 slots (NV-700) in total are used. Example - if you require 13V / 20A :- a) Select B as closest match for voltage & current and prefix with voltage eg 13BH b) Repeat for other outputs. This will create a complete product description eg NV3SSSES5V 13BH 12/15DB which represents a three output NV350 with Forward air cooling, Screw input terminals, standard leakage filter, ac good, PSU enable & 5V/2A aux supply Output 1 = 13V / 20A. Output 2 = 12V / 13A with screw terminals. Output 3 = 15V / 4A with screw terminals Max 350W continuous output power 3. Contact TDK-Lambda to validate configuration and issue a part number. DUAL OUTPUT MODULES SINGLE OUTPUT MODULES Module Output 1 Output 2 Module Output 1 Current Max Code Slots Voltage Range Continuous Peak Code Slots Voltage Range Current Voltage Range Current Power 3.2 - 3.6 40A 1 48W DA 12 (fixed) 3A -12 (fixed) 1A 40A 8 8 B 2 4.75 - 5.5 3 3.3 - 5.5 10A 55W 22.5A 7 - 9 4 DB 2 3.2 - 3.6 25A 7 - 15 5A 60W 20A 12 - 15.5 5 BH 2 24 - 32 2A 50W 10A 24 - 28 6 3.3 - 5.5 10A 55W 37.5A 50A 12 - 13.2 7 7 DB 2 4.75 - 5.5 25A 7 - 15 5A 60W 30A 37.5A 15 - 16.5 7 7 24 - 32 2A 50W C 3 18.75A 25A 24 - 26.4 DB 2 5.5 - 6.5 25A 3.3 - 5.5 10A 55W 7 7 16.6A 19.7A 3.3 - 5.5 10A 55W 27 - 32 7 7 DB 2 12 - 15 13A 7 - 15 5A 60W 18.75A 25A CM 3 24 - 26.4 1 7 7 24 - 32 2A 50W 18.75A 25A 48 - 52.8 9 9 CC 6 3.3 - 5.5 10A 55W 16.6A 19.7A 54 - 64 9 9 DB 2 24 - 28 7A 7 - 15 5A 60W 2 24 - 32 2A 50W Higher output voltages available by connecting output modules in series. Contact technical support for details 1. Derate linearly from 13A at 12.5V to 10A at 15.5V 6. For NV3 - derate linearly from 10A at 25.7V to 8.5A at 28V 2. Derate linearly from 7A at 25V to 6A at 28V For NV7 - derate linearly from 10A at 24V to 8.5A at 28V 3. For NV3 - derate linearly from 40A at 5.2V to 36A at 5.5V 7. For NV3 - 400W max For NV7 - derate linearly from 40A at 5V to 36A at 5.5V For NV7 - 600W peak for up to 10sec, 450W average 4. Derate linearly from 22.5A at 8V to 20A at 9V 8. Only one per power supply, 48W max total power for module 5. For NV3 - derate linearly from 20A at 13.2V to 16.5A at 15.5V 9. For NV3 - limited by total output power, see below For NV7 - derate linearly from 20A at 12.5V to 15.5A at 15.5V OUTPUT POWER 90-115Vac 115-150Vac 150-180Vac 180-264Vac Comments Continuous 350W 450W 450W 660W 1. 350W average 5. 1150W average 6 NV-350 2. 450W average 6. 250W for reverse air Peak (10s) 400W 500W 500W 740W 7 1 2 2 3 3. 600W average 7. Not for reverse air Continuous 700W 700W 1150W 1150W 4. 700W average NV-700 Peak (10s) 850W 1150W 1450W 4 5 Output Specification Voltage / Current See module tables Turn on time 1.5s max at 90Vac and 100% rated output power Rise time <50ms to 90% of voltage, monotonic rise above 10% (27-32V C module < 100ms) Efficiency up to 90% configuration dependent Hold up 16ms min at 90Vac and 100% rated power (12ms for NV-700) Ripple and Noise <1% or 50mV if greater pk-pk, using EIAJ test method & 20MHz bandwidth Voltage Accuracy <1% of set voltage (DA module: +5/-1% for channel 1, +2/-3.5% for channel 2) standard on single o/p + ch1 of dual modules, max 0.5V total line drop Remote Sense Yes (DA module: None) Minimum Load No on any output (DA module: 150mA on channel 1) of rated voltage per C Temperature Coefficient <0.02% Load Regulation <1% for 0-100% load change (<2% for channel 2) (DA module: <3%) Line Regulation <0.1% for 90-264Vac input change Cross Regulation <0.1% for 100% load change on any output (DA module: 0.2% for channel 1, 3% for channel 2) Transient Response <4% of set voltage for 50% load change Recovery 500s for recovery to 1% of set voltage (DA module: 1000s) Over Voltage Protection Yes NV350 NV700 Datasheet 69528 - v29.0 NV-350 / NV-700 2