PAH200H Series High Current Half Brick DC-DC Converters Features Industry Standard Package Low voltage outputs to 0.96V Output Currents up to 70A Designed for telecom standards Output voltage adjustment Remote On / O High E ciency Wide adjustment range ASIC Design No potting materials Key Market Segments & Applications Speci cations PAH200H48-1R2 PAH200H48-1R5 PAH200H48-1R8 PAH200H48-2R5 PAH200H48-3R3 Model (/C version) (/C version) (/C version) (/C version) (/C version) Nominal Output Voltage VDC 1.2 1.5 1.8 2.5 3.3 Output Current (Max) A 70 (60) 70 (60) 70 (60) 70 (60) 60 (50) Max Output Power W 84 (72) 105 (90) 126 (108) 175 (150) 198 (165) E ciency (Typ) % 82 84 87 88 90 Input Voltage range VDC 36 - 76V (100V for 100ms) Input Current (typ) A 2.18 (1.87) 2.66 (2.28) 3.08 (2.64) 4.23 (3.63) 4.68 (3.90) Output Voltage Accuracy % 1 Output Voltage Adjustment V 0.96-1.32 1.2-1.65 1.44 - 1.98 2.0 - 2.75 2.805 - 3.795 Max Ripple & Noise mV 100 Max Line Regulation mV 10 Max Load Regulation mV 10 Overcurrent Protection - 105 - 140% (See Options) Overvoltage Protection - 120 - 140% (See Options) Remote Sense - Yes Remote On / O - Yes (See options) Operating Temperature - -40C to +85C (100C /B option) Baseplate temperature Operating Humidity - 5 - 95% Non condensing Storage Temperature - -40C to +100C Cooling - Convection, or forced air I/O Isolation Voltage - Input to Output 1500VAC Output to Case 500VAC 2 Vibration (non operating) - 10~55Hz (1 minute), amplitude 0.825mm (49m/s max), X, Y, Z 1 hr ea. 2 Shock - 196.1 m/s Safety Agency Approvals - UL1950, CSA950, EN60950, & CE Weight (Typ) g 90 Size (WxHxD) in(mm) 2.28 x 0.4* x 2.4 (57.9 x 10.2* x 61) * /B version 0.5 (12.7) Warranty yrs Two Years Note: See Installation Manual for full details, test methods of parameters and application notes. Last Time Buy March 2019 1-800-526-2324 www.us.tdk-lambda.com/lp/ 232 Disclaimer: us.tdk-lambda.com/lp/legal.htmPAH200H Series Outline Drawing Outline Drawing Options Pinout Su x OCP / OVP Remote On / O k Pin Description Function Blank Manual Reset Negative, Short = On -Vin Negative Input Terminal /V* Auto Reset Negative, Short = On +Vin Positive Input Terminal /P Manual Reset Positive, Open = On CNT On / O Control terminal /PV* Auto Reset Positive, Open = On +V Positive Output Terminal /C** Single set of O/P pins -V Negative Output Terminal /B Baseplate Fitted TRIM Output adjustment Trim pin Note Su x letter order: /C followed by /P followed by /V +S Positive Remote sense Example: /CPV. -S Negative Remote sense * Standard US Stock Item. ** See website for outline drawingnot available with /B option. Other DC-DC Products PAF 500, 600, & 700W Full brick DC-DC PAH 50W to 350W Half brick DC-DC For Additional Information, please visit PAQ Up to 100W Quarter brick DC-DC us.tdk-lambda.com/lp/products/pah200h-series.htm SX 20W surface mount 24V & 48VDC-DC X 10, 15, 20W 24V & 48VDC Input DC-DC converters 1-800-526-2324 www.us.tdk-lambda.com/lp/ 233 Revision A6: Mar 2018