PFE-SA, PFE500-F & PFE1000-FA Series Specifications Model PFE300SA PFE700SA PFE500F PFE1000FA PFE500SA Input Input Voltage Range Vac 85 - 265 Input Frequency Hz 47 - 63 (Contact factory for 400Hz operation) Input Current A See model selector table Inrush Current at 230Vac (typ) (Cold Start) A 46 (with recommended inrush resistor) Leakage Current mA less than 0.75 Power Factor (100/200Vac) - >0.95 Hold Up Time (typ) at 110/220Vac Input ms 20 Efficiency - See model selector table Conducted & Radiated EMI - EN55011/EN55032-A, FCC Class A, VCCI-A (External components are required, consult Evaluation Data) Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11 (External component are required, consult Immunity Data) Safety Certifications and Markings - IEC/UL/CSA/EN62368-1, 60950-1, CE Mark and UKCA Mark Immunity Test Standard Test Level Criteria Notes ESD EN61000-4-2 Air 8kV and contact 4kV B 80M -1GHz: 10V/m Radiated Susceptibility EN61000-4-3 1.4 - 2.0GHz: 3V/m A 2.0 - 2.7GHz: 1V/m Electrical Fast Transient Burst EN61000-4-4 2kV B Normal 2kV Surge EN61000-4-5 B Common 4kV 6kV with the external surge suppressor Conducted Susceptibility EN61000-4-6 10Vrms A Magnetic Fields EN61000-4-8 30A/m A 30% 500ms B 60% 10ms B Voltage Dips EN61000-4-11 100% 20ms A 100% 5000ms B 2 PFE-SA, PFE500-F & PFE1000-FA Series