PXF Series 40W & 60W Single, Dual, Triple Output DC-DC Converters Features Industry Standard 2 x 2 Footprint Six Sided Shielding Agency Approved 12, 24V, and 48V Inputs (including 4:1 ranges) UL, CSA, EN, CE approvals Wide range input Key Market Segments & Applications Speci cations Model Maximum Output Power 40W or 60W Voltage Accuracy (Full Load, Nom. Vin) Single, Dual and Triple Main 1%, Triple Auxiliaries 5% Voltage Adjustment (1) 10% (Single and Dual Output Only) Minimum Load, each output (2) Single Output = 0%, Dual and Triple = 10% of full load rating Line Regulation Single / Dual 0.5%, Triple (main) 1%, Triple (auxiliary) 5% Load Regulation (10% to 100%) (3) Single 0.5%, Dual 1%, Triple (main) 2%, Triple (auxiliary) 5% Cross Regulation (25% to 100%) (4) Triple (main) 1%, Dual/Triple (auxiliary) 5% Start up time PXF40: 25ms typ., PXF40xxW, PXF60: 20ms max. Remote on/o (referenced to negative input) Positive Logic: ON: Open or 3.0-12V, OFF Short or <1.2V Temperature Coe cient <0.02%/C Operating Temperature See derating curves Maximum Case Temperature PXF40: 100C, PXF40-xxW 105C, PXF60 110C Storage Temperature PXF40: -55 to 105C, PXF40xxW, PXF60 125C Thermal Shock MIL-STD-810F Relative Humidity (non condensing) 5 to 95% Transient Response (25% step load change) 250us recovery Overvoltage Protection (Zener clamp) Typical 3.3V: 3.9V, 5V: 6.2V, 12V: 15V, 15V: 18V Overcurrent and Short Circuit Protection Typically at 150%, hiccup with self recovery Input Surge Voltage (Maximum for 100ms) 12V input: 36V, 24V input: 50V, 48V input: 100V Re ected input ripple (peak to peak) (5) PXF40: 40mA, PXF40xxW, PXF60: 20mA Isolation Voltage Input - Output, Input to Case: 1600VDC minimum 9 Isolation Resistance 10 Ohms minimum Isolation Capacitance (max) PXF40, PXF60: 1000pF, PXF40xxW: 2500pF Switching Frequency (Fixed) 300kHz (typ.) MTBF (BELLCORE TR-NWT-000332) PXF40: 1,398,000 PXF40xxW: 1,105,000, PXF60: 1.093,000 hours Vibration 10 - 55Hz, 10G, 30 minutes each X, Y, Z axis Conducted and Radiated Emissions See Installation Diagrams Immunity EN61000-4-2, -3, -4, -5, -6 Safety Agency Approval IEC/UL/CSA/EN 62368-1, 60950-1, CE Mark Size (L x W x H) 2 x 2 x 0.4 Weight 2.11 oz (60g) Warranty Three Year Refer to application notes on website for external circuitry and PCB layout. (1) Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense and - Sense should be connected to their corresponding outputs + output, -output. (2) Dual and Triple output models require a minimum load of 10% on the output to maintain speci ed regulation. No load operation will not damage the device. (3) Load regulation for triple output: Main output:10-100%, with 10-100% balanced load on auxiliaries. Auxiliary outputs: 10% to 100% balanced on all outputs. (4) Cross regulation for dual output: asymmetrical load 25% / 100% full load. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%. Auxiliary outputs: main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100%. (5) Simulated Source impedence of 12uH placed in series with + input.PXF Series Model Selector Outline Drawing PXF40-xx(S,T,D) Output Output Input Ripple/Noise Max Load Volt(V) Curr(A) Volt(VDC) Model (mV) E .(%) Cap(uF)) Single Outputs 3.3 8 9 - 18 PXF40-12S3P3 50 84 21000 3.3 10 9 - 36 PXF40-24WS3P3 50 86 25750 3.3 8 18 - 36 PXF40-24S3P3 50 87 21000 3.3 10 18 - 75 PXF40-48WS3P3 50 86 25750 3.3 14 18 - 36 PXF60-24S3P3 75 89 36000 3.3 8 36 - 75 PXF40-48S3P3 50 88 21000 3.3 14 36 - 75 PXF60-48S3P3 75 89 36000 5 8 9 - 18 PXF40-12S05 50 86 13600 5 8 9 - 36 PXF40-24WS05 50 87 13600 5 8 18 - 36 PXF40-24S05 50 89 13600 5 8 18 - 75 PXF40-48WS05 50 88 13600 5 8 36 - 75 PXF40-48S05 50 90 13600 5 12 18 - 36 PXF60-24S05 75 90 20400 5 12 36 - 75 PXF60-48S05 75 90 20400 12 3.333 9 - 18 PXF40-12S12 75 86 2360 12 3.333 9 - 36 PXF40-24WS12 75 87 2360 12 3.333 18 - 36 PXF40-24S12 75 88 2360 12 3.333 18 - 75 PXF40-48WS12 75 87 2360 12 3.333 36 - 75 PXF40-48S12 75 89 2360 12 5 18 - 36 PXF60-24S12 100 90 3550 12 5 36 - 75 PXF60-48S12 100 90 3550 15 2.666 9 - 18 PXF40-12S15 75 87 1510 15 2.666 9 - 36 PXF40-24WS15 75 87 1510 Derating Curves 15 2.666 18 - 36 PXF40-24S15 75 89 1510 15 2.666 18 - 75 PXF40-48WS15 75 87 1510 PXF40-48S05 & PXF60-48S05 15 2.666 36 - 75 PXF40-48S15 75 89 1510 15 4 18 - 36 PXF60-24S15 100 90 2300 Derating Curve 15 4 36 - 75 PXF60-48S15 100 90 2300 Dual Outputs 100 12 1.667 9 - 36 PXF40-24WD12 120 86 1200 12 1.8 9 - 18 PXF40-12D12 120 85 1200 75 12 1.8 18 - 36 PXF40-24D12 120 87 1200 12 1.667 18 - 75 PXF40-48WD12 120 86 1200 50 12 1.8 36 - 75 PXF40-48D12 120 87 1200 15 1.333 9 - 36 PXF40-24WD15 150 86 750 25 15 1.4 9 - 18 PXF40-12D15 150 85 750 15 1.4 18 - 36 PXF40-24D15 150 87 750 0 -40 -25 -10 0 40 50 60 70 80 90 100 110 15 1.333 18 - 75 PXF40-48WD15 150 86 750 15 1.4 36 - 75 PXF40-48D15 150 87 750 Triple Outputs 3.3V,12V 6.0,0.4 9 - 18 PXF40-12T3312 50 / 75 83 13000,330 3.3V,12V 6.0,0.4 18 - 36 PXF40-24T3312 50 / 75 85 13000,330 Pinout PXF40-xx(S,T,D) 3.3V,12V 6.0,0.4 36 - 75 PXF40-48T3312 50 / 75 86 13000,330 5V,12V 6.0,0.4 9 - 18 PXF40-12T0512 50 / 75 85 6800, 330 Function 5V,12V 6.0,0.4 18 - 36 PXF40-24T0512 50 / 75 87 6800, 330 PIN Single Output Dual Output Triple Output 5V,12V 6.0,0.4 36 - 75 PXF40-48T0512 50 / 75 88 6800, 330 1 + Input + Input + Input 5V, 15V 6.0, 0.3 9 - 18 PXF40-12T0515 50/75 86 6800, 110 2 - Input - Input - Input 5V, 15V 6.0, 0.3 18 - 36 PXF40-24T0515 50/75 87 6800, 110 3 Remote on/o Remote on/o Remote on/o 5V, 15V 6.0, 0.3 36 - 75 PXF40-48T0515 50/75 88 6800, 110 4 No Connection No Pin + Aux 5 - Sense (Note 1) + VO Common 6 + Sense (Note 1) Common -Aux Heat Sink (0.22 high) 7 + Output Common + Output HAPXF (includes thermal adhesive pad) 8 - Output - VO - Output (Com) HAPXFCLIP (two clips required when used) 9 Trim Trim N/C Other Industrial Products For Additional Information, please visit