ZMS100 Series www.emea.tdk-lambda.com/zms 80W Convection, 100W Forced-Air Cooled /( ,QGXVWULDO 7 HVW %URDGFDVW 0HGLFDO &RPP Single Output Power Supplies Features Benefits Long e-cap lifetime Better field reliability and service life Compact 2 x 4 inch footprint Space saving in end equipment Medical approval with 2 x MoPP isolation Suitable for B and BF type medical equipment Suitable for Class I and Class II installations Flexible utilisation Ceramic start-up cap Eradicates start-up cap dry out problems (1) Specification Model ZMS100 (2) (4) AC Input Voltage range - 85 - 264VAC (47-63Hz) Input Fusing Line and neutral Input Current (230V/115Vac) A 1.0 / 2.0 Inrush Current - cold start A <40 (max at 264Vac input) Harmonic Compliance - Compliant to EN/IEC61000-3-2 class A Temperature Coefficient - <0.02% / C Hold Up Time at 80W load,115/230Vac ms 22 / 108 (see graphs for more detail) Hold Up Time at 100W load,115/230Vac ms 16 / 84 (see graphs for more detail) Leakage Current A <100A at 100V 60Hz input, <250A at 230V 50Hz Touch Current (enclosure leakage) A <100 A Cooling - 80W with convection cooling, 100W max. with forced air cooling (see airflow rate graphs) Efficiency - Up to 90% (see efficiency curves) Operating Temperature C -20C to +70C, derate linearly to 50% load from 50C to 70C Storage Temperature C -40C to +85C Operational Altitude - 5000m Overcurrent Protection hiccup (auto recovery) Overvoltage Protection Latching (unit shutdown, recycle mains to restart) No Load Input Power at 230Vac W <0.5 Average Active Efficiency % >87 Humidity (non condensing) RH Operating and storage : 5 - 95% (non-condensing) Withstand Voltage - Input to output 4kVac 2x MoPP, 1.5kVac input to ground 1x MoPP, 1.5kVac output to ground 1 x MoPP Isolation Resistance >100M at 25C & 70%RH (3) Isolation Class Construction suitable for Class II installations Vibration - 10 to 500Hz at 2G, EN60068-2-6 19,6m/s Constant, X, Y, Z 1 hour each. Shock - 30G EN60068-2-27, -47, MIL-STD-810E IEC/EN/UL/CSA 62368-1, 60950-1 and 60601-1, ANSI/AAMI ES 60601-1, Approvals - CE Mark. Designed to meet IEC/EN/UL/CSA 61010-1:2010. ZMS100-12, 15 and 24 are type tested to EN 60335-1. (5) Conducted & Radiated EMI EN 55011 / EN 55032 level B conducted, level A radiated Weight g 150 Size (W x L x H) mm 50.8 x 101.6 x 31.9 Warranty yrs 3 Molex as standard with separate ground faston Connectivity Input Molex 10-63-4027, output Molex 09-65-2048 Notes: 1. Specification parameters apply at 25C ambient temperature unless stated otherwise. 2. For 12V & 15V unit derate from 100% at 100V to 90% at 90V and to 80% at 85V, for 24V, 36V, & 48V unit derate from 100% at 90V to 90% at 85V. (convection and forced air ratings) . 3. ZMS100 uses Y1 capacitors to earth. 4. Consult Sales Office for use under DC Input conditions. 5. Additional measures will be needed if used in environments where Class B radiated is required. 1 ZMS100 SeriesModel Selector (6) Nominal Output Maximum Maximum Maximum Maximum Ripple Load Reg Line Reg Model Output Adjust Current Current Output Power Output power and noise from 0 - full from 85-264Vac Voltage (V) Range (V) Convection (A) Forced Air (A) Convection (W) Forced Air (W) (mv pk-pk) load (mv) (mv) ZMS100-12 12 11.4 to 13.2 6.7 8.4 80.4 100.8 120 120 60 ZMS100-15 15 14.25 to 16.5 5.4 6.7 81.0 100.5 150 150 75 ZMS100-24 24 22.8 to 26.4 3.4 4.2 81.6 100.8 240 240 120 ZMS100-36 36 34.2 to 39.6 2.25 2.8 81.0 100.8 360 360 180 ZMS100-48 48 45.6 to 52.8 1.67 2.1 80.2 100.8 480 480 240 Note: 6. At 115Vac input, 25C. Immunity Levels Test Standard Test Level Criteria Notes ESD EN61000-4-2 4 A Radiated Susceptibility EN61000-4-3 3 A inc proximity field requirements of EN60601-1-2:2015 Electrical Fast Transient Burst EN61000-4-4 4 A (AC Port, 5kHz and 100KHz) Surge EN61000-4-5 3 A - Conducted Susceptibility EN61000-4-6 3 A - Magnetic fields EN61000-4-8 4 A - 0% for 1/2 cycle A/B A up to 94W, B above 94W EN61000-4-11 0% for 1 cycle A/B A up to 54W, B above 54W Class 3 Industrial 40% for 10/12 cycles B - inc EN55024 70% for 25/30 cycles A/B A up to 54W, B above 54W (100VAC) 80% for 250/300 cycles A/B A up to 94W, B above 94W 0% for 250/300 cycles B - 0% for 1/2 cycle A 100W EN61000-4-11 0% for 1 cycle A 100W Voltage Dips Class 3 Industrial 40% for 10/12 cycles A - & Interruptions inc EN55024 70% for 25/30 cycles A - (240VAC) 80% for 250/300 cycles A - 0% for 250/300 cycles B - 0% for 1/2 cycle A/B A up to 94W, B above 94W EN60601-1-1:2015 0% for 1 cycle A/B A up to 54W, B above 54W (100VAC) 70% for 25/30 cycles A/B A up to 54W, B above 54W 0% for 250/300 cycles B - 0% for 1/2 cycle A 100W EN60601-1-1:2015 0% for 1 cycle A 100W (240VAC) 70% for 25/30 cycles A - 0% for 250/300 cycles B - Ringwave Test EN61000-4-12 3 A - Voltage Fluctuations EN61000-4-14 Class 3 A - 2 ZMS100 Series