ZUP SERIES Programmable CVCC 200W 800W19Model 800W 3 200W, 400W Features Model naming method ZUP 36 - 12 / Constant Voltage/Constant Current Built-in RS232 & RS485 Interface Serial Link Cable An embedded Microprocessor controller Series name Output Output W. Cable included Voltage Current BLANK: None Digital Encoder Knob ( 0 36V ) ( 0 12A ) AC Cable Front Panel Software Calibration E. Europe L. Output Jacks U. USA BLANK: Standard Last Setting Memory O. Unterminated I: SI 32 std. Parallel Operation (Master/Slave) Active Current BLANK: None Sharing Applications External Voltage or Resistance Programming Voltage up to 120V, Current up to 132A Active Power Factor Correction: 99% 85265Vac Universal Input Voltage 19 Rack Mounted ATE and OEM Worldwide Safety Agency Approvals Conformity to RoHS Directive CE Mark for LVD and EMC Regulation This means that, in conformity with EU Directive 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. Product Line up 200W 400W 800W Output Voltage Output Current Model Output Current Model Output Current Model 0-6V 0-33A ZUP6-33 0-66A ZUP6-66 0-132A ZUP6-132 0-10V 0-20A ZUP10-20 0-40A ZUP10-40 0-80A ZUP10-80 0-20V 0-10A ZUP20-10 0-20A ZUP20-20 0-40A ZUP20-40 ZUP 0-36V 0-6A ZUP36-6 0-12A ZUP36-12 0-24A ZUP36-24 0-60V 0-3.5A ZUP60-3.5 0-7A ZUP60-7 0-14A ZUP60-14 0-80V 0-2.5A ZUP80-2.5 0-5A ZUP80-5 0-120V 0-1.8A ZUP120-1.8 0-3.6A ZUP120-3.6 All specifications are subject to change without notice. A-341ZUP SERIES ZUP Specifications MODEL Z U P 6 - 3 3 Z U P 6 - 6 6 Z U P 6 -13 2 Z U P10 -2 0 Z U P10 - 4 0 Z U P10 - 8 0 Z U P 2 0 -10 ITEMS/UNITS OUTPUT VOLTAGE (*1) V 0-6 0-10 OUTPUT CURRENT (*2) A 0-33 0-66 0-132 0-20 0-40 0-80 0-10 RATED OUTPUT POWER W 198 396 792 200 400 800 200 LOAD REGULATION 0.005%+2mV From No load to Full load, constant input voltage. LINE REGULATION 0.005%+1mV From 85-132VAC or 170-265VAC, constant load. RMS RIPPLE (5Hz-1MHz Bandwidth) mV 5 5 8 5 5 8 5 RIPPLE (pk to pk) (20MHz Bandwidth) mV 50 50 100 50 50 90 50 CONSTANT RECOVERY TIME (*3) mS 1 0.5 VOLTAGE TEMPERATURE COEFFICIENT 30ppm/C from rated voltage following 30-minute warm-up. TEMPERATURE DRIFT 0.01%+2mV Change in output over 8-hour interval under constant line, load and ambient temp following30-minute warm-up. UP PROGRAMMING RESPONSE TIME (*4) mS 50 50 60 50 50 60 50 DOWN PROGRAMMING FULL LOAD mS 50 50 50 50 50 50 50 RESPONSE TIME NO LOAD mS 250 350 LOAD REGULATION (*5) 0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA LINE REGULATION (*6) 0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA CONSTANT RMS RIPPLE (5Hz-1MHz Bandwidth) mA 50 100 200 25 50 100 15 CURRENT TEMPERATURE COEFICIENT 100ppm/ C from rated current following 30-minute warm-up. TEMPERATURE DRIFT (*8) 0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA RESOLUTION Better than 0.028% of rated output voltage PROGRAM VOLTAGE ACCURACY 0.02%+5mV 0.02%+8mV MING (*9) RESOLUTION Better than 0.03% of rated output current CURRENT ACCURACY 0.4%+40mA OVERVOLTAGE PROTECTION (*10) V 0-7.5 0-13 HOLD-UP TIME 20mS At 100V/200VAC, rated output voltage and output current. VOLTAGE 3 digits ( 6v 20v 36v 60v 80v) 3.5 digits ( 10v 120v ) accuracy: 0.2% +/- 2 digits. DISPLAY CURRENT 3.5 digits (132A) All others 3 digits, accuracy: 0.5% +/- 3 digits. STATUS CV/CC, Alarm, Fold, Local/Remote, On/Off. OUTPUT PROTECTIONS Over Voltage, Over Temperature, Foldback. INPUT VOLTAGE (*11) 85-265Vac Continuous, 47-63Hz INPUT CURRENT (*12) A 3.0/1.5 5.6/2.7 11.2/5.4 2.9/1.4 5.6/2.7 11.2/5.4 2.9/1.4 INRUSH CURRENT ( 100/200V ) A 15/30 (*7) 15 30 15/30 (*7) 15 30 15/30 (*7) INPUT EFFICIENCY ( *12 ) % 69/72 74/77 74/77 73/77 79/82 77/81 74/78 INPUT CURRENT HARMONICS Complies with EN61000-3-2, Class A POWER FACTOR (TYP) 0.99 at 100/200Vac, 100% load. OPERATING TEMPERATURE 0 to 50 C 100% Load. OPERATING HUMIDITY 30-90% RH ( No dewdrop ). ENVIRONMENT STORAGE TEMPERATURE -20 to 70 C STORAGE HUMIDITY 10 - 95% RH (No dewdrop). VIBRATION 10-55Hz, Amplitude (sweep 1 min ) 2G, X, Y, Z, When mounted with mounting screws. SHOCK Less than 20G MECHANICAL WEIGHT Kg 2.9 3.2 5.8 2.9 3.2 5.8 2.9 SIZE (W x H x D) mm 200W and 400W units: 70 x 124 x 350. 800W units: 140 x 124 x 350 (Refer to outline drawing) OUTPUT ON/OFF By TTL Signal or Dry Contact (Refer to instruction manual). OUTPUT GOOD Open collector (Refer to instruction manual). EXTERNAL OUTPUT VOLTAGE PROGRAMMING By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual). CONTROL OUTPUT CURRENT PROGRAMMING By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual). FUNCTIONS REMOTE SENSING Maximum 0.5V drop on each load wire for model up to 60V and 2V for the 80V, 120V models COMMUNICATION INTERFACE RS232 and RS485 Built-in, IEEE488 Optional. SAFETY STANDARDS UL3111-1, EN61010-1 APPROVALS EMC STANDARDS EN61326-1, IEC 61326-1, FCC part 15 (class A). CONDUCTED EMI EN55022-B, FCC-B, VCCI-2 RADIATED EMI EN55022-A, FCC-A, VCCI-1 SERIES OPERATION Up to 2 units (Refer to instruction manual). PARALLEL OPERATION Master - Slave method up to 5 units (Refer to instruction manual). COOLING Forced air by blower fan (Blower fan is mounted within unit). WITHSTAND VOLTAGE Input - Chassis...2.0kVAC 1 min, Input - Output...3.0kVac 1 min, Output - GND...500VAC 1 min. ISOLATION RESISTANCE More than 100MOhm at 25 C and 70% R.H. (*1) Minimum voltage is guaranteed to maximum 0.2% of the rated out- (*8) Change in output over 8 hour interval constant line, load and ambi- put voltage. ent temperature following 30-minutes warm-up. (*2) Minimum current is guaranteed to maximum 0.4% of the rated out- (*9) Given for control of the output via the serial communication or via put current. front panel controls. (*3) Time for recovery to within +/-50mV against current change of 50% (*10) Inverter shut down method, manual reset (OVP will shut down out- to 100%. put) ZUP (*4) From zero volts to full scale , resistive load and current setting at (*11) For cases where conformance to various safety specs. (UL, IEC, maximum. etc.) are required, to be described as 100-240VAC (50/60Hz) on name plate. (*5) From no load to full load , constant input voltage. (Measure with JEITA RC-9131 probe.) (*12) At 100V/200V and Maximum Output Power. - When forced air cooling, refer to derating curve. (*6) From 85~132Vac or 170~265Vac constant load. (*7) At cold start Ta=25 C. A-342 All specifications are subject to change without notice.