TD K-Lambda ZW Q130/ A SPECIFICATIONS (CONVECTION COOLING) A191-01-01/A-D MODEL ZWQ130-5223/A ZWQ130-5225/A ITEMS V1 V2 V3 V4 V1 V2 V3 V4 1 Nominal Output Voltage V +5 +12 -12 +3.3 +5 +12 -12 +5 2 Minimum Output Current (Convection) ( * 1 ) A 1.5 0 0 0 1.5 0 0 0 3 Minimum Output Current (Peak Applica(t*io1n)) A 2.1 0 0 0 2.1 0 0 0 4 Maximum Output Current A 15.0 4.0 4.0 10.0 15.0 4.0 4.0 10.0 5 Total Allowable Output Power (*2) W 130 6 Maximum Peak Output Current (*3) A 19.0 5.0 5.0 12.0 19.0 5.0 5.0 12.0 7 Total Allowable Peak Output Power (*2) W 149.6 170 8 Efficiency (Typ) (*4) % 72 9 Input Voltage Range (*5) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC 10 Input Current (100/200VAC) (Typ) (*4) A 2.0/1.0 o 11 Inrush Current (Typ) (*6) - 14A at 100VAC, 28A at 200VAC, Ta=25 C, Cold Start 12 PFHC - Designed to meet IEC61000-3-2 13 Power Factor (100/200VAC) (Typ) (*4) - 0.99 / 0.93 14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 2.0-3.63 5.0-5.25 +12/+15 -12/-15 2.0-5.25 15 Output Voltage Accuracy - - 5% 5% - - 5% 5% - o o 16 Maximum Ripple & Noise(*7) 0 C <Ta< +50 C mV 120 150 150 120 120 150 150 120 -10 <Ta< 0C mV 160 180 180 160 160 180 180 160 17 Maximum Line Regulation (*7,8) mV 20 48 48 20 20 48 48 20 18 Maximum Load Regulation (*7,9) mV 100 300 300 100 100 300 300 100 o 19 Temperature Coefficient - Less than 0.02% / C 20 Over Current Protection (*10) - More than 152W of Total Output Power More than 173W of Total Output Power 21 Over Voltage Protection (*11) V 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 3.79 - 4.95 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 5.7 - 7.0 22 Hold-Up Time (Typ) (*12) - 20 ms 23 Leakage Current (*13) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC 24 Remote ON/OFF Control - - 25 Parallel Operation - - 26 Series Operation - - o o o 27 Operating Temperature (*14) - -10 - +50 C (-10 - +30 C : 100%, +50 C : 50%) 28 Operating Humidity - 30 - 90%RH (No Dewdrop) o 29 Storage Temperature - -30 - +85 C 30 Storage Humidity - 10 - 95%RH (No Dewdrop) 31 Cooling - Convection Cooling 32 Withstand Voltage Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC(100mA), for 1min. o 33 Isolation Resistance - More than 100M W at 25 C and 70%RH Output - FG : 500VDC 34 Vibration - At no operating, 10-55Hz (Sweep for 1min) 2 19.6 m/s Constant, X, Y, Z 1h each. 2 35 Shock (In package) - Less than 196.1 m/s 36 Safety (*15) - Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1 Designed to meet DENAN 37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B 38 Immunity (*16) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11 39 Weight (Typ) - 1000g 40 Size (WxHxD) mm 108.5 x 44.5 x 250 (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. For V2, V3,V4 stability, require minimum output current of V1. *10. Constant current limit with automatic recovery. Refer to test data (A191-53-01 ). *2. Allowable output power is changed according to V4 voltage Not operate at over load or dead short condition for more than 30 seconds. refer to derating table (A191-01-05/A- ). *11. OVP circuit will shut down all outputs, manual reset (Line recycle). *3. Operating period at peak current is less than 10sec. (Duty < 0.35) *12. At 100/200VAC, nominal output voltage and total allowable output power. o o *4. *13. At 100/200VAC, Ta=25 C and total allowable output power. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 C. *5. For cases where conformance to various safety specs (UL, CSA, EN) are required, *14. At standard mounting. to be described as 100 - 240VAC(50/60Hz). - Load (%) is percent of total allowable output power or *6. Not applicable for the inrush current to Noise Filter for less than 0.2ms. each maximum output current, whichever is greater. *7. Refer to output measuring (A191-01-07/A- ) for line & load regulation For other mountings, refer to derating curve (A191-01-05/A- ). and ripple voltage. *15. As for DENAN, built to meet at 100VAC. *8. 85 - 265VAC , constant load. *16. Refer to test data(A191-58-01 ). *9. Minimum load - Full load, constant input voltage. DENSEI-LAMBDA ZWQ130/A SPECIFICATIONS (FORCED AIR COOLING) A191-01-02/A-D MODEL ZWQ130-5223/A ZWQ130-5225/A ITEMS V1 V2 V3 V4 V1 V2 V3 V4 1 Nominal Output Voltage V +5 +12 -12 +3.3 +5 +12 -12 +5 2 Minimum Output Current (*1) A 2.1 0 0 0 2.1 0 0 0 3 Maximum Output Current A 19.0 5.0 5.0 12.0 19.0 5.0 5.0 12.0 4 Total Allowable Output Power (*2) W 149.6 170 5 Input Current (100/200VAC) (Typ) (*3) A 2.6/1.3 o o o 6 Operating Temperature (*4) - -10 ~ +60 C (-10 ~+40 C : 100%, +60 C : 50%) 7 Cooling (*5) - Forced Air Cooling *Read instruction manual carefully, before using the power supply unit. =NOTES= *For other items, refer to convection cooling specifications (A191-01-01/A- ). *1. For V2, V3,V4 stability, require minimum output current of V1. When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling. *2. Allowable output power is changed according to V4 voltage, refer to derating table (A191-01-06/A- ). o *3. At 100/200VAC, Ta=25C total allowable output power. *4. At standard mounting. - Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. For other mountings, refer to derating curve (A191-01-06/A- ). 3 *5. Air flow > 0.85m /min(30cfm)