ZWS-AF Series 50W to 150W Single Output Low Cost, Worldwide Use Features u Universal Input (85 - 265VAC) u Power factor Corrected u Input transient protected u 2 year warranty u High quality design u Peak Power capability Key Market Segments & Applications Speci cations Model ZWS50AF ZWS75AF ZWS100AF ZWS150AF AC Input Voltage range VAC 85-265VAC (47-63Hz) DC Input Voltage range VDC 120-370VDC Input Current (Typ) (1) A 0.8/0.4 1.2/0.6 1.4/0.7 2.0/1.0 Inrush Current A 14/28 25C Ambient, Cold Start Power Factor (1) - Meets EN61000-3-2 (0.99/0.95) Maximum Ripple and Noise mV 3.3 & 5V: 120mV 12 to 24V: 150mV 36 & 48V: 200mV Temperature Coef cient - <0.02%/C Overcurrent Protection (4) - >105% of Peak Current Capability Hold Up Time (Typ) (1) ms 20ms Leakage Current - 0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC Remote On / Off - See installation manual (Not available with /A cover option) Operating Temperature - Convection cooling - See table on page 2 0.7m/s air -10C to +70C, derate linearly to 70% load from 60C to 70C (2) Storage Temperature - -30 to +85C Humidity (non condensing) - Operating: 30 - 90% RH, storage 10-95% RH Withstand Voltage - I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark Conducted & Radiated EMI - designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B Immunity - designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11 Weight (Typ) g 210 290 380 500 Size (W x H x D) mm 55 x 26 x 195 55 x 32 x 222 62 x 35 x 222 75 x 40 x 222 Warranty yrs Two Years Notes: (1) 100/200VAC (2) ZWS150AF -10 to 60C, derate linearly to 70% load from 50C to 60C (3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35% (4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds. (5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input. For New Designs, See ZWSBAF Series 1-800-526-2324 www.us.tdk-lambda.com/lp/ 1 Disclaimer: us.tdk-lambda.com/lp/legal.htmZWS-AF Series Model Selector Output Max Max Max Peak Max Max Adjust Curr. Peak Output Output Eff. Load Line OVP 3 3 5 Model Voltage Range (V) (A) Curr. (A) Power (W) Power (W) (%) Reg.(mV) Reg.(mV) (V) ZWS75AF3 3.3V 2.85-3.63 15.0 - 49.5 - 67 40 20 3.79-4.95 ZWS100AF3 3.3V 2.85-3.63 20.0 - 66.0 - 69 40 20 3.79-4.95 ZWS150AF3 3.3V 2.97-3.63 30.0 - 99.0 - 74 40 20 3.79-4.95 ZWS50AF5 5V 4.5-5.5 10.0 - 50.0 - 75 40 20 5.75-7.0 ZWS75AF5 5V 4.5-5.5 15.0 - 75.0 - 75 40 20 5.75-7.0 ZWS100AF5 5V 4.5-5.5 20.0 - 100.0 - 75 40 20 5.75-7.0 ZWS150AF5 5V 4.5-5.5 30.0 - 150.0 - 77 40 20 5.75-7.0 ZWS50AF12 12V 10.8-13.2 4.3 5.2 51.6 62.4 78 96 48 13.8-16.2 ZWS75AF12 12V 10.8-13.2 6.3 7.5 75.6 90.0 78 96 48 13.8-16.2 ZWS100AF12 12V 10.8-13.2 8.5 10.0 102.0 120.0 79 96 48 13.8-16.2 ZWS150AF12 12V 10.8-13.2 12.5 15.0 150.0 180.0 79 96 48 13.8-16.2 ZWS50AF15 15V 13.5-16.5 3.5 4.2 52.5 63.0 79 120 60 17.3-20.3 ZWS75AF15 15V 13.5-16.5 5.0 6.0 75.0 90.0 79 120 60 17.3-20.3 ZWS100AF15 15V 13.5-16.5 6.7 8.0 100.5 120.0 79 120 60 17.3-20.3 ZWS150AF15 15V 13.5-16.5 10.0 12.0 150.0 180.0 81 120 60 17.3-20.3 ZWS50AF24 24V 21.6-26.4 2.1 2.6 50.4 62.4 81 150 96 27.6-32.4 ZWS75AF24 24V 21.6-26.4 3.2 3.8 76.8 91.2 82 150 96 27.6-32.4 ZWS100AF24 24V 21.6-26.4 4.3 5.0 103.2 120.0 81 150 96 27.6-32.4 ZWS150AF24 24V 21.6-26.4 6.3 7.5 151.2 180.0 82 150 96 27.6-32.4 ZWS75AF36 36V 32.4-39.6 2.1 2.5 75.6 90.0 82 200 144 41.4-48.6 ZWS100AF36 36V 32.4-39.6 2.8 3.4 100.8 122.4 82 200 144 41.4-48.6 ZWS150AF36 36V 32.4-39.6 4.2 5.0 151.2 180.0 82 200 144 41.4-48.6 ZWS75AF48 48V 43.2-52.8 1.6 1.9 76.8 91.2 82 240 192 55.2-64.8 ZWS100AF48 48V 43.2-52.8 2.1 2.5 100.8 120.0 82 240 192 55.2-64.8 ZWS150AF48 48V 43.2-52.8 3.2 3.8 153.6 182.4 82 240 192 55.2-64.8 Other Industrial Products Options VSB/VSC 5W-150W Single output 115VAC input Suf x Description SC 30W-120W Single, dual & triple output - Molex Input & Output Connectors HWS 15W-1500W Single output /A With cover & L Bracket ZWSPAF 150W-480W Peak power, single output /J JST Input & Output Connectors* ZWD, ZWQ 100W-440W Dual and quad output /JA JST Connectors & Cover * Recommended for new designs Derating - Convection Cooling For Additional Information, please visit Model 40C 45C 50C 55C 60C us.tdk-lambda.com/lp/products/zws-series.htm ZWS50AF 100% 100% 100% 85% 70% ZWS75AF 100% 100% 100% 85% 70% ZWS100AF 100% 100% 100% 80% 60% ZWS150AF 100% 87% 75% 62% 50% 1-800-526-2324 www.us.tdk-lambda.com/lp/ 2 Revision A4: May 2012