ZWS-PAF Series 150W to 480W Single Output Power Supplies Features u Universal Input (85 - 265VAC) u Power factor Corrected u 200% Peak Power capability u 2 year warranty u Less than 0.5mA earth leakage current u Input Transient Protected Key Market Segments & Applications Speci cations Model ZWS150PAF ZWS240PAF Input Voltage - 85-265VAC (47-63Hz), 120-370VDC Input Current (Forced air (1) A 2.8/1.4 4.0/2.0 Inrush Current (1,2) A 14 / 28 Power Factor - 0.99 at 100VAC, 0.95 at 200VAC, Meets EN61000-3-2 Leakage Current mA 0.5mA Max. Typically 0.1mA (100VAC), 0.22mA (230VAC) Temperature Coef cient - <0.02%/C Overcurrent Protection (3) - >102% of peak current capability Overvoltage Protection V 24V: 30-35V, 36V: 43.2-50.4, 48V: 55.2-64.8V Hold Up Time (Typ) at 100VAC ms 20 (16ms at forced air power ratings) Ef ciency % 82 Remote On/Off - See installation manual (Not available with /A cover option) Line Regulation % 0.4% Load Regulation % 0.8% Ripple & Noise % 1% Operating Temperature (4) C (Open frame or L bracket) -10C to +70C, derate linearly to 70% load from 60C to 70C Operating Temperature (4) C (With /A cover option) -10C to +60C, derate linearly to 70% load from 50C to 60C Storage Temperature C -30 to +85C Humidity (non condensing) - Operating: 30 - 90% RH, Operating: 10 - 95% RH Cooling - Convection or Forced Air Cooled (1.5m/s) Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. Isolation Resistance - >100M at 25C & 70% RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s constant X, Y, Z 1 hour 2 Shock - < 196.1 m/s Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark Conducted & Radiated EMI - EN55022/EN55022-B, FCC Class B, VCCI-B Recommended EMI Filter - RSEL-2006W Immunity - EN61000-4-2, -3, -4, -5, -6, -8, -11 Weight (Typ) g 500g (800g with cover) 750g (1100g with cover) Size (WxHxD) mm See Outline Drawings Warranty yrs Two Years Notes: (1) 100/200VAC (2) 25C ambient (cold start) (3) Avoid prolonged operartion in overload (4) With 0.7m/s air ow. See derating table for convection cooling 1-800-526-2324 www.us.tdk-lambda.com/lp/ 117 Disclaimer: us.tdk-lambda.com/lp/legal.htmZWS-PAF Series Model Selector Max Max Max Max Adjust Current Power Current Power Peak Peak (6) (6) (5) (5) Model Voltage Range Convection Convection Forced Air Forced Air Current Power ZWS150PAF24 24V 21.6 - 28.8V 6.3A 151.2W 8.4A 201.6W 12A 288W ZWS150PAF36 36V 32.4 - 41.4V 4.2A 151.2W 5.6A 201.6W 8A 288W ZWS150PAF48 48V 43.2 - 52.8V 3.1A 148.8W 4.3A 206.4W 6A 288W ZWS240PAF24 24V 21.6 - 28.8V 10A 240W 12.5A 300W 20A 480W ZWS240PAF36 36V 32.4 - 41.4V 6.7A 241.2W 8.4A 302.4W 13.3A 478.8W ZWS240PAF48 48V 43.2 - 52.8V 5A 240W 6.3A 302.4W 10A 480W Note 5: For 10s maximum, 35% duty cycle, average power not to exceed maximum ratings Note 6: With 1.5m/s forced air Model Derating for Conducted Cooling Model 25C 30C 35C 40C 45C 50C 55C 60C ZWS150PAF** 100% 100% 100% 100% 100% 100% 85% 70% ZWS150PAF**/A 100% 100% 90% 80% 72.5% 65% - - ZWS240PAF** 100% 100% 100% 100% 100% 86.7% 73.3% 60% ZWS240PAF**/A 100% 90% 80% 70% 60% 50.0% - - ZWS150PAF Outline Drawing ZWS150PAF/TL Outline Drawing BAR CODE MADE IN CHINA ZWS150PAF-24 A BAR CODE MADE IN CHINA ZWS240PAF Outline Drawing Options Suf x Option Blank Molex Input & Output Connectors BAR CODE /L L Bracket MADE IN CHINA /A Cover and L Bracket /J JST Input & Output Connectors /T Vertical Mount Screw Terminals /S Horizontal Mount Screw Terminals Preferred option combinations: Blank, /L, /TL or /TA. ZWS240PAF/TL Outline Drawing Example: ZWS240PAF24/TA BAR CODE Other Industrial Products VSB/VSC 10W to 150W Single output 115VAC input ZWS 5W to 150W Single output, 115/230VAC input SC 30W to 120W Single, dual & triple output HWS 15W to 1500W Single output, enclosed For Additional Information, please visit us.tdk-lambda.com/lp/products/zws-series.htm 1-800-526-2324 www.us.tdk-lambda.com/lp/ 118 Revision A4: Dec 2011