Single Output 5W - 300W ZWS SERIES ZWS300 ZWS50 ZWS75AF/JA (with cover option) ZWS30 ZWS150AF ZWS15 ZWS100AF ZWS10 ZWS5 ZWS75AF 2 ZWS50AF Features Model naming method CE marking applicable ZWS 105/ Full line-up from 5W through 300W Option Small leak current: 0.5mA max ZWS-AF Blank: Molex connector, PCB type A: Molex connector, with cover ON/OFF control/output voltage trimmer (ZWS-AF) J: JST connector, PCB type Applicable to a wide range of usages, including print- JA: JST connector, with cover ers for business use and air conditioners Output voltage Complies the harmonics current limit standard by Output power built-in active filter ZWS-AF Series name ZWS 3005/ Option Series Output Output Applications R: With remote ON/OFF control power voltage name T: Vertical terminal type B: Input/output connector terminal type Only for 12V-48V output type Conformity to RoHS Directive This means that, in conformity with EU Directive 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. Product Line up ZWSSingle Output In case of new design is requined, please refer to ZWS-AF series. 5W 10W 15W 30W 50W 300W Output Voltage Current(Peak) Model Current(Peak) Model Current(Peak) Model Current(Peak) Model Current(Peak) Model Current(Peak) Model 3.3V ZWS5-3 ZWS10-3 ZWS15-3 ZWS30-3 ZWS50-3 ZWS300-3 1.0A1.2 2.0A2.4 3.0A3.6 6.0A7.2 10A12 40A60 5V ZWS5-5 ZWS10-5 ZWS15-5 ZWS30-5 ZWS50-5 ZWS300-5 12V 0.42A0.51 ZWS5-12 0.85A1.02 ZWS10-12 1.25A1.5 ZWS15-12 2.5A3.0 ZWS30-12 4.3A5.16 ZWS50-12 17A27 ZWS300-12 15V 0.34A0.41 ZWS5-15 0.7A0.84 ZWS10-15 1.0A1.2 ZWS15-15 2.0A2.4 ZWS30-15 3.5A4.2 ZWS50-15 14A22 ZWS300-15 24V 0.22A0.27 ZWS5-24 0.45A0.54 ZWS10-24 0.65A0.78 ZWS15-24 1.3A1.56 ZWS30-24 2.1A2.52 ZWS50-24 9A14 ZWS300-24 36V 0.9A1.08 ZWS30-36 1.4A1.68 ZWS50-36 48V 0.7A0.84 ZWS30-48 1.1A1.32 ZWS50-48 4.2A6.3 ZWS300-48 ZWS-ASF ingle Output, Built-in Active Filter 50W 75W 100W 150W ZWS Output Voltage Current(Peak) Model Current(Peak) Model Current(Peak) Model Current(Peak) Model 5V 10A ZWS50AF-5 15A ZWS75AF-5 20A ZWS100AF-5 30A ZWS150AF-5 12V 4.3A5.2 ZWS50AF-12 6.3A7.5 ZWS75AF-12 8.5A10 ZWS100AF-12 12.5A15 ZWS150AF-12 15V 3.5A4.2 ZWS50AF-15 5.0A6.0 ZWS75AF-15 6.7A8.0 ZWS100AF-15 10A12 ZWS150AF-15 24V 2.1A2.6 ZWS50AF-24 3.2A3.8 ZWS75AF-24 4.3A5.0 ZWS100AF-24 6.3A7.5 ZWS150AF-24 All specifications are subject to change without notice. A-403ZWS5 ZWS5 Specifications MODEL Z W S 5 - 3 Z W S 5 - 5 Z W S 5 -12 Z W S 5 -15 Z W S 5 -24 ITEMS/UNITS Voltage Range (*3) V AC85 - 265 or DC110 - 330 Frequency (*3) Hz 47 - 440 Input Efficiency (typ) (*2) 62 67 68 70 Current (100/200VAC)(typ) A 0.14 / 0.07 Inrush Current (100/200VAC)(typ) A 15 / 30 at Ta=25, cold start Nominal Voltage V 3.3 5 12 15 24 Minimum Current A 0 Maximum Current A 1 0.42 0.34 0.22 Maximum Peak Current (*1) A 1.2 0.51 0.41 0.27 Maximum Power W 3.3 5.0 5.04 5.1 5.28 Maximum Peak Power (*1) W 3.96 6.0 6.048 6.12 6.336 Output Maximum Line Regulation (*4)(*10) mV 20 48 60 96 Maximum Load Regulation (*5)(*10) mV 40 96 120 150 Temperature Coefficient (*6) mV 60 140 180 280 Maximum Ripple & Noise (0 to +60) (*10) mVp-p 120 150 200 Maximum Ripple & Noise (10 to 0) (*10) mVp-p 160 180 200 Hold-up Time (100VAC)(typ) (*2) ms 17 at 5W, Ta=25 Voltage Adjustable Range +/-10% Over Current Protection (*7) >125% Over Voltage Protection (*8) >140% Function Parallel Operation - Series Operation (*9) Possible Operating Temperature (*11) -10 to +50: 100%, +60: 70% Storage Temperature -30 to +85 Operating Humidity RH 30 - 90 Environment Storage Humidity RH 10 - 95 Vibration 10-55Hz (sweep 1min) less than 19.6m/s X, Y, Z 1h each Shock Less than 196.1m/s Cooling Convection cooling Withstand Voltage Input - FG: 2kVAC (20mA), Input - Output: 3kVAC (20mA), Output - FG: 500VAC (100mA) for 1min Isolation Isolation Resistance More than 100M at 25 and 70%RH Output - FG 500VDC Safety Standards Approved by UL60950-1,CSA C22.2 No.60950-1,EN60950-1, Built to meet DENAN Standards EMI Built to meet EN55022-B, FCC-ClassB, VCCI-B Weight (typ) g 120 Mechanical Size (W x H x D) mm 45 x 21 x 98 (*1) Operating time at peak output is less than 10 seconds. (Duty=0.35) Recommended EMC Filter (*2) At 100VAC and maximum output current, Ta=25. (*3) For cases where conformance to various safety specs (UL,CSA) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*4) From 85 - 265VAC and constant load. (*5) From min load - full load (maximum power) and constant input voltage. (*6) From -10 to +50 constant input voltage and load. Measurement point for Vripple (*7) Current limiting with automatic recovery. L RSEL-20R5W Avoid to operate over load or dead short for 30 seconds. Please refer toTDK-Lambda (*8) Over voltage clamping by zener diode. EMC Filter catalog. (*9) Refer to instruction manual. C2 C1 CN2 (*10) Please refer to Fig A for measurement of line & load regulation and ripple voltage. (*11) At standard mounting method, Fig B. L:150mmAWG 22 Measurement point C1:Elec.Cap 100uF Measurement point for Vo, for Vripple L C2:Film Cap 0.1uF Line/Load Regulation. Bandwidth of scope:100MHz Fig.A C2 C1 CN2 COMPONENT SIDE PCB L:150mmAWG 22 C1:Elec.Cap 100uF Measurement point for Vo, Fig.B C2:Film Cap 0.1uF Line/Load Regulation. Bandwidth of scope:100MHz Fig.A COMPONENT SIDE PCB ZWS Fig.B A-404 All specifications are subject to change without notice.