Special Load PCB Relay RP 3 SL 1 pole 16 A, for high inrush currents, mono- or bistable Features 1 N/O contact 120 A / 20 ms inrush peak current DC- or bistable version 4 kV / 8 mm coil-contact Applications Lighting control, timers, motor control, building automation VZK Technical data of approved types on request F0147-A Contact data Configuration 1 N/O contact Type of contact single contact Rated current 16 A Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac Maximum breaking capacity AC 4000 VA Make current (max. 4 s at duty cycle 10%) 25 A Peak inrush current 120 A Contact material AgSnO 2 Contact ratings Type Load Operations Standard 5 RP3SL 12 A, 250 Vac, cosj=1 3x10 3 RP3SL TV 8 25x10 UL 508 4 RP3SL 2500 W, 230 Vac, halogen lamps >10 5 RP3SL 1000 W, 250 Vac, incandescent lamps 2.3x10 4 RP3SL 3000 W, 250 Vac, incandescent lamps 3.6x10 4 RP3SL 1500 VA, fluorescent lamps 163 F 10 Coil data monostable DC coil Nominal voltage 5...110 Vdc Nominal coil power 500 mW Operate category 2 / b Coil versions monostable DC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc Vdc Vdc c mA 012 12 9.0 1.2 21.6 270++10% 44.4 ++ 024 24 18.0 2.4 43.2 1100 15% 21.8 048 48 36.0 4.8 86.4 4400+15% 10.9 060 60 45.0 6.0 108.0 6540+15% 9.2 All figures are given for coil without preenergization, at ambient temperature +20C Other coil voltages on request Edition: 03/2002Special Load PCB Relay RP 3 SL 1 pole 16 A, for high inrush currents, mono- or bistable Coil data bistable 1 coil 2 coils Nominal voltage 5...110 Vdc 5...60 Vdc Nominal coil power 1.2...1.4 W 1.2...1.5 W Minimum energization time 20 ms Reset voltage min. 70 % U 75 % U nom nom Reset voltage max. 110 % U 120 % U nom nom Coil versions bistable Coil Nominal Pull-in Reset Reset Coil Coil code voltage voltage voltage R1 resistance current Vdc Vdc Vdc c / W c mA bistable, 1 coil A05 5 3.7 3.6 39 / 0.5 21+10% 238.1 A12 12 9.0 8.7 220 / 0.5 115+10% 104.3 Circuit scheme for bistable 1 coil A24 24 18.0 16.7 820 / 0.5 460+10% 52.2 bistable, 2 coils F12 12 9.0 9.0 105+15% 114.3 F24 24 18.0 18.0 460+15% 52.2 All figures are given for coil without preenergization, at ambient temperature +20C, duty cycle 20% Other coil voltages on request Insulation Dielectric strength coil-contacts 4000 V rms open contact circuit 2000 V rms Clearance / creepage 8 / 8 mm PCB layout / terminal assigment Insulation to IEC 60664 View on solder pins Dimensions in mm Voltage rating 250 V Pollution degree 3 Overvoltage category III Insulation to VDE 0110b (2/79) Insulation category / reference voltage C / 250 S0163-CR Other data Ambient temperature -40...+70 C 6 Mechanical life 30x10 operations -1 -1 Max. switching rate at rated- / minimum load 10 min / 1200 min Operate- / release time monostable typ. 8 / 2 ms Operate- / reset time bistable typ. 6 / 2 ms Bounce time typ. 2 ms Vibration resistance 20 g, 30...300 Hz S0163-CS Shock resistance (destruction) 100 g Protection category RT II - flux proof, RT III - wash tight Bistable versions: Relay weight 18 g Indicated contact position during or after coil Packaging unit 1 coil 20 / 500 pcs. energization with reset voltage. 2 coils 25 / 100 pcs. Accessories see accessories RP 2-coil versions: Operate A2, A3 Reset A1, A3 b) for 2 coil version only Edition: 03/2002