Category 6 SL Series Modular Jacks 1375055-X, 1375187-X, 1375188-1 1.20 1.20 .57 .57 1.20 .57 .64 .64 .64 CommScopes Category 6 SL series modular jacks exceed ANSI/TIA-568-C.2 and ISO/ IEC 11801 component requirements and Category 6/Class E system performance. CommScopes Category 6 System complies with all of the performance requirements for current and proposed applications such as Gigabit Ethernet (1000BASE-TX), 10 and 1 OOBASE-TX, loken ring , 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog and digital video, and analog and digital voice (VoIP). CommScopes Category 6 SL Series Modular Jacks have a slim profile connectors shall be capable of terminating 22-24 AWG solid or 24- and are compatible with SL Series and 11OConnecl faceplates. 26 AWG stranded conductors. The insulation displacement contacts Universal wiring labels permit termination to either T568A or shall be paired, with additional space between pairs, to improve T5688 wiring patterns. Modular jack are available in shielded and crosstalk performance. Modular jacks shall utilize a secondary PC unshielded options. The unshielded jacks offer an optional integral board, separate from the signal path, for crosstalk compensation. dust cover. Unshielded jacks allow cables to be dressed at either Earn modular jack shall meet the ANSI/TIA-568-C.2 and ISO/ IEC 180 (rear) or 90 (either side) for added flexibility. Patented bend- 11801 component requirements and Category 6/Class E system limiting strain relief may also be used to reduce stress on cable at performance standards and the requirements listed in table 1. point of termination and is included with each unshielded modular Modular Jacks shall be compatible with CommScope SL Series jack. SL Series Modular Jacks are available in almond, black, gray, termination tool part number 1725150-1. Each unshielded modular orange, blue, red, yellow, green, violet, electrical ivory and alpine jack shall be provided with a bendlimiting strain relief. The strain white (see part number table for color samples). relief shall provide cylindrical support to limit the bend radius at SPECIFICATION (TEXT IN BRACKETS the point of termination. Each jack shall incorporate an integral, REQUIRES A CHOICE) hinged dust cover . Modular jacks shall be UL listed under file number E81956. Modular jacks shall be CommScope part number Modular jacks shall be unkeyed, unshielded or shielded , 4-pair, 1375055-X, 1375187-X or 1375188-1 (X denotes color, see part RJ-45, and shall fit in a .790 X .582 opening. Modular jacks number table) and be almond, black, gray, orange, blue, red, shall terminate using 11O-style pc board connectors, colorcoded yellow, green, violet, electrical ivory or alpine white in color. for both T568A and T5688 wiring. Each modular jack shall be wired to T568A or T568B . The 11O-style insulation displacement Table 1: Worst-Case Performance Characteristics (exceed EIA/TIA and ISO/IEC Category 6/Class E requirements) Insertion Loss (dB) Return Loss (dB) NEXT (dB) FEXT (dB) Category 6 Max Category 6 Min Category 6 Min Category 6 Min Frequency Standard Standard Standard Standard MHz 1 0.10 0.02 30 52.4 75.0 84.8 75.0 83.7 4 0.10 0.02 30 53.7 75.0 80.3 71.1 74.8 8 0.10 0.02 30 55.3 75.0 77.4 65.0 69.4 10 0.10 0.03 30 56.1 74.0 76.4 63.1 67.5 16 0.10 0.03 30 57.6 69.9 72.0 59.0 62.9 20 0.10 0.04 30 59.3 68.0 71.9 57.1 61.7 25 0.10 0.04 30 59.4 66.0 69.1 55.1 59.8 31.25 0.11 0.05 30 56.8 64.1 67.7 53.2 58.2 62.5 0.16 0.06 28 42.3 58.1 61.5 47.2 52.6 100 0.20 0.06 24 33.2 54.0 57.7 43.1 48.7 200 0.28 0.06 18 21.2 48.0 52.5 37.1 42.2 250 0.32 0.10 16 17.4 46.0 47.9 35.1 40.1 Specifications Materials Modular Jack Housing: Polycarbonate, 94V-0 rated 110 Connecting Blocks: Polycarbonate, 94V-0 rated Contacts: Beryllium copper, plated with 1.27m 50in thick gold in localized area and 3.81m 150in minimum thick matte tin in solder area over 1.27 m 50 in minimum thick nickel underplate Insulation Displacement Contacts: Phosphorous bronze, plated with 3.81m 150in minimum thick matte tinlead over 1.27m 50in minimum thick nickel underplate Integral Dust Cover: Polycarbonate Shield: Copper zinc alloy 260, pre-plated with bright nickel Strain Relief: Polycarbonate Electrical Characteristics Modular Jack: 750 mating cycles Voltage: 150VAC m 110 Contacts: 200 terminations Operating Temperature: -40 70C (-40 158F) Pull Force: 20lbs (89N) Packaging Modular Jack: 1 per bag, 25 per carton Strain Relief: 1 per bag Approvals: w UL Listed, file number E81956, CSA *0.058 0.063in 0.582in *0.058 0.063in 0.582in 0.582in 0.582in 1.47 - 1.60mm * 14.78mm 0.310in 0.310in 1.47 - 1.60mm * 14.78 1m4m.7 8 mm 14.78mm 7.92mm 7.92mm *NOTE: Panel thickness is *NOTE: P anel thickness is *NOTE: P anel thickness is applicable to both Single applicable to both S ingle P anel applicable to both S ingle P anel 0.560in and F lush Mount Cutout S tyles. 0.560in and F lush Mount Cutout S tyles. 0.790in 0.800in 16.51mm 0.790in Panel and Flush Mount 0.800in 16.51mm 20.07mm 20.32mm 20.07mm 20.32mm Cutout Styles. Single Panel Cutout Suggested Flush Mount Panel Application Cutout Single PSingle anel CPanel Cutoututout Suggested Flush Mount PSuggested Flush Mount Panelanel ApplicationApplication C Cutoututout 2 Category 6 SL Series Modular Jacks 1375055-X, 1375187-X, 1375188-1