Multimode Relay MT 2 / 3 pole 10 A, DC- or AC-coil Features 2 C/O or 3 C/O contacts Cadmium-free contacts DC and AC coils Mechanical indicator as standard Electrical indicator New test system with front operated finger protected push-to-test button and integral locking test tab White write on panel Applications Mechanical engineering, plant control F0161-A VZs Technical data of approved types on request Contact data Configuration 2 C/O contact or 3 C/O contact Type of contact single contacts bifurcated contacts Rated current 10 A 4 A Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac Maximum breaking capacity AC 2500 VA 500 VA Make current (max. 4 s at duty cycle 10%) 20 A 8 A Contact material AgNi 90/10 Minimum contact load 24 V, 10 mA / 20 mV, 1 mA gold plated Contact ratings Type Load Operations Standard 5 MT321 10 A, 250 Vac, C/O contact 1x10 VDE 0435 Coil data Nominal voltage DC coil 6...220 Vdc AC coil 6...230 Vac Nominal coil power DC coil typ. 1.2 W AC coil typ. 2.3 VA Operate category 1 / a Coil versions, DC-coil Coil code Nominal Pull-in Release Coil Coil * standard PD voltage voltage voltage resistance current Vdc Vdc Vdc c mA 006 0A6 6 4.5 0.6 32+10% 187.5 012 0B2 12 9.0 1.2 110+10% 109.1 024 0C4 24 18.0 2.4 475++10% 50.5 048 0E8 48 36.0 4.8 2000+10% 24.0 060 0G0 60 45.0 6.0 2850+10% 21.1 110 1B0 110 82.5 11.5 10000+12% 11.0 220 2C0 220 165.0 22.0 40000+15% 5.5 All figures are given for coil without preenergization, at ambient temperature +20C * Protection diode PD standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10 Edition: 03/2002Multimode Relay MT 2 / 3 pole 10 A, DC- or AC-coil Coil versions, AC-coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vac Vac Vac Vac c mA 006 6 4.8 2.4 7.8 5.3+10% 381.7 012 12 9.6 4.8 15.6 24+10% 182.5 ++ 024 24 19.2 9.6 31.2 86 10% 94.2 048 48 38.4 19.2 62.4 345+10% 47.5 060 60 48.0 24.0 78.0 544+10% 37.8 115 115 92.0 46.0 149.5 2000+10% 20.6 230 230 184.0 92.0 299.0 8300++12% 10.1 All figures are given for coil without preenergization, at ambient temperature +20C Insulation Dielectric strength coil-contacts 2500 V Terminal assignment rms open contact circuit 1500 V View on solder pins rms adjacent contacts 2500 V rms Clearance / creepage 2.8 / 4 mm Insulation to IEC 60664 Voltage rating 250 V Pollution degree 3 S0168-B Overvoltage category III Insulation to VDE 0110b (2/79) C / 250 Tracking resistance of relay base CTI 175 Other data Flammability class according to UL 94 V-0 Dimensions Ambient temperature DC-coil -45...+60 C Dimensions in mm AC-coil -45...+50 C 6 Mechanical life >20x10 operations -1 -1 Max. switching rate at rated- / minimum load 20 min / 100 min S0296-A Operate- / release time 12 / 5 ms Bounce time 4 ms Vibration resistance N/O / N/C contact >5 / 2 g Shock resistance (function) N/O contact / N/C contact >50 / 10 g Category of protection (IEC 61810) RT I - dust protected Relay weight 80 g Packaging unit 25 pcs. Accessories see accessories MT Edition: 03/2002