InstructionSheet 408--8452 7000Series4-PoleTimingRelay 14MAR 11 RevA 1. INTRODUCTION Model 7024 This instruction sheet covers the installation and L1 L2 operation of the AGASTAT* 7000 Series 4--Pole 1 2 Timing Relays (Models 7014 and 7024). Read these instructions thoroughly before installing the relay. TD Dimensions in this instruction sheet are in NOTE 5 3 4 6 on millimeters with inches in brackets . Figures are Drop-- not drawn to scale. Out 8 7 2. DESCRIPTION (Figure1) Each relay is a precise timing instrument which 11 9 10 12 balances pneumatic, electrical, and mechanical forces using a minimum of moving parts. When satisfactory Delay Setting performance cannot be restored, the unit should be returned to TE Connectivity for repair. Energized Coil De--Energized Contacts Open N.C. (1--5)(2--6) Closed N.O. (3--5)(4--6) Open Closed 4--Pole Timing Relay (Typ) Open Contacts N.C. (7--11)(8--12) Closed N.O. (9--11)(10--12) Open Model 7014 Closed L2 L1 2 1 LINEARTIMINGRANGES TIMERANGE MODEL7014D MODEL7024 TD CODE 3 5 4 6 on Pick-- A 0.2to2Seconds 0.1to1Second Up 8 7 B 0.7to7Seconds 0.5to5Seconds C 2to20Seconds 1.5to15Seconds 11 10 12 9 D 10to100Seconds 5to50Seconds E 30to300Seconds 20to200Seconds Delay Setting F 1.5to15Minutes 1to10Minutes Energized Coil H 3to30Minutes 3to30Minutes De--Energized N.C. (3--5)(4--6) Closed I Not Available 6to60Minutes Open Contacts J Not Available 3to120Cycles Closed K Not Available 1to300Cycles N.O. (1--5)(2--6) Open D Model 7014is availablewithletter calibrateddials only. Theupper N.C. (9--11)(10--12) Closed endof thetimeranges inthis model may betwicethevalues shown. Open Contacts Closed N.O. (7--11)(8--12) Open Figure 1 (contd) E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company TOOLING ASSISTANCE CENTER 1--800--722--1111 This controlled document is subject to change. 1 of 2 All Rights Reserved PRODUCT INFORMATION 1--800--522--6752 For latest revision and Regional Customer Service, TE logo is a trademark. visit our website at www.te.com LOCB *Trademark. Other product names, logos, or company names might be trademarks of their respective owners.408-8452 3. MOUNTINGINSTRUCTIONS (Figure2) ACCOILUNITS DCCOILUNITS Normal mounting of the relay is in a vertical position, RATED RATED CODE CODE RATED from the back of the panel. Four No. 8--32 tapped VOLTAGE VOLTAGE LETTER LETTER VOLTAGE holes are provided in the back plate. AT 60 Hz AT 50 Hz A 120 110 M 28 Mounting screws should not project more than CAUTION 3.63 mm 5/32 in. into the back of the unit, to B 240 220 N 48 prevent internal damage. C 480 -- O 24 A bracket and required screws are supplied with each D 550 -- P 120 unit for mounting the unit from the front. The bracket extends approximately 9.52 mm 3/8 in. from each E 24 -- Q 12 side of the unit. F -- 127 R 60 Horizontal operation is not recommended. NOTE G -- 240 S 250 H 12 -- T 550 Models 7014 and 7024 (Mounting Dimensions) I 6 -- U 16 82.5 3.25 J 208 -- V 32 73.2 2.88 W 96 44.4 9.6 .38 DualVoltageCoil K Y 6 1.75 ((CCoommbbiinneessAA aannddBB)) 5.1 .199 Dia Z 220 Mtg Holes 12.7 AC Specials L1, L2, etc. DC Specials X1, X2, etc50 Operational voltagerange90% to120% for AC units: 85% to120% for DC units. All units draw approximately 8watts power at ratedvoltage. 38.1 Minimumoperatingvoltages arebasedonvertically mountedModel 1.50 7014(on--delay) units. 147.8 8--32Mtg 5.82 AC units dropout at approximately 50% of ratedvoltage. DC units Holes (4) dropout at approximately 40% of ratedvoltage. Max. 19.0 76.2 All units may beoperatedonintermittent duty cycleatvoltages 10% .75 63.5 above the listed maximums. (Intermittent duty -- maximum50% duty 3.00 2.50 cycleand30minutes ontime.) Coils arerated6Vac through550Vac. CONTACTRATINGS 65.3 (ContactCapacityinAmperes -- ResistiveLoads) 2.57 Max. CONTACT MINIMUM100,000 MINIMUM1,000,000 VOLTAGE OPERATIONS OPERATIONS 84.3 30Vdc 15.0 7.0 3.32 Max. 110 Vdc 1.0 0.5 120Vac60Hz 20.0 15.0 240Vac60Hz 20.0 15.0 480Vac60Hz 12.0 10.0 Figure 2 Inductiveandcapacitiveloads shouldnot haveinrushcurrents that 4. QUALIFICATIONS exceed five times normal operatingload. Contact ratings arelistedunder theUnderwriters Laboratories Inc. The 7000 Series Timing Relays are Listed by Component RecognitionProgramfor 100,000operations: Underwriters Laboratories Inc. (UL) in File E15631. 10A Resistive, 240Vac (per pole) and Certified to CSA International in File LR29186. 1/4Horsepower, 120Vac/240Vac (per pole) 15A, 30Vdc (per pole) 5A, General Purpose, 600Vac Total loadmust not exceedtwicetheabovelistings per polerating. 5. REVISIONSUMMARY Continuous duty ratingis 25amperes any voltage, any load. S Updated document to corporate requirements Figure 1 (end) S New logo 2 of 2 Rev A