Signal Relays AXICOM IM Relay 2 n Slim line 10x6mm, low profile 5.65mm and min. board-space 60mm n Switching current 2/5A, switching power 60W/62.5VA and switching voltage 220VDC/250VAC n Low coil power consumption, 140mW standard, 100mW for high sensitive version, 50mW for ultra high sensitive version and 100mW for bistable version n High dielectric and surge capability up to 2500Vrms between open IM contacts and 2500Vrms between coil and contacts n High mechanical shock resistance up to 50g functional Typical applications Telecommunication, access and transmission equipment, optical network terminals, modems, office and business equipment, consumer electronics, 108-98001 Rev. M AXICOMSignalRelays measurement and test equipment, industrial control, medical equipment, U IM Relay HVAC Approvals Contact Data (continued) Contact Data UL 508 File No. E 111441 Electrical endurance Technical data of approved types on request at contact application 0 IM-A IM-B IM-C IM-D IM-E 6 (30mV/10mA) min. 2.5x10 operations Number of contacts and type 1Polebreak 1Polemake 1Pole 2Polebreak 2Polemake 6 Contact Data standard, C D, I P changeover cable load open end min. 2.0x10 operations 5 Contact assembly Bifurcatedcontacts standard and high high contact resistive, 125VDC / 0.24A - 30W min. 5x10 operations 5 Contact material Palladium-ruthenium,gold-covered high dielectric current stability resistive, 220 VDC / 0.27A - 60W min. 1x10 operations 5 Limiting continuous current 2A2A 4A2A 2A version version version resistive, 250VAC / 0.25A - 62.5VA min. 1x10 operations at max. ambient temperature 5 Contact arrangement 2 form C, 2 CO resistive, 30VDC / 1A - 30W min. 5x10 operations Maximum switching current 2A 2A 3A 2A 2A 5 Max. switching voltage 220VDC, 220VDC, 220VDC, resistive, 30VDC / 2A - 60W min. 1x10 operations Maximum swichting voltage 220Vdc 250VAC 250VAC 250VAC UL contact rating 30VDC, 2A, 60W, NO only 250Vac Maximum switching capacity Rated current 2A 5A 2A 60W,62.5 VA 110VDC, 0.3A, 33W Thermoelectric potential Limiting continuous current 2A 5A 2A <10 V 220VDC, 0.27A, 60W Minimum switching voltage 100V Switching power 60W, 62.5VA 125VAC, 0.5A, 62.5W 108-98001 Rev. M AXICOMSignalRelays Initial contact resistance / < 100 m < 100 m NO < 100 m < 50 m < 50 m Contact material PdRu AgNi PdRu 250VAC, 0.25A, 62.5W measuring condition: 10 mA / 20 mV 8 +Au +Au +Au Mechanical endurance IM Rela10 y operations Electrical CC0 Contact category 0 endurance ( 30 mV / 10 mAcover) ed covered covered 6 min.2.5x10operations cable load open end 6 min.2.0x10operations Contact style twin cont. twin cont. twin cont. I: single contacts Coil Data Resistive load at 125 Vdc / 0.24 A - 30 W Coil Operating Range 5 min.5x10operations at 220 Vdc / 0.27 A - 60 W 5 Minimum switching voltage 100V min.1x10operationsMagnetic system monostable, bistable at 250 Vac / 0.25 A - 62.5 5 min.1x10operations Initial contact resistance <50m at 10mA/30mV Coil voltage range 1.5 to 24VDC VA 5 min.5x10operations U = Nominal coil voltage nom at 30 Vdc / 1 A - 30 W I: < 100m 3.4 5 50mW coil min.1x10operations at 30 Vdc / 2 A - 60 W 3.2 100mW coil U = Upper limit of the operative range of max. Thermoelectric potential <10V Coil versions, standard version, monostable, 1 coil 3 Mechanical endurance 8 typ.10 operations the coil voltage (limiting voltage) when Umax. at 2x1A Operate time typ. 1ms, max. 3ms Coil Rated Operate Release Coil Rated coil 2.8 Umax. at 0A UL contact ratings 220 Vdc / 0.24 A - 60 W coils are continously energized 2.6 Release time code voltage voltage voltage resistance power 125 Vdc / 0.24 A - 30 W 2.4 Umax. at 0A U = Lower limit of the operative range of 250 Vac / 0.25 A - 62.5 VA op. min. without diode in parallel typ. 1ms, max. 3ms VDC VDC VDC 10% mW 2.2 125 Vac / 0.5 A - 62.5 VA the coil voltage (reliable operate voltage) 2 with diode in parallel typ. 3ms, max. 5ms 00 1.5 1.13 0.15 16 140 30 Vdc / 2 A - 60 W 1.8 For latching relays Uset min. resp. Bounce time max. typ. 1ms, max. 5ms 08 2.4 1.80 0.24 41 140 Umax. at 2x2A 1.6 Ureset min. 01 3 2.25 0.30 64 140 1.4 Max. DC Load Breaking Capacity 1.2 U = Lower limit of the operative range of 02 4.5Unom. nominal coil voltage3.38 0.45 145 140rel. min . 1 the coil voltage (reliable release voltage) Max. DC load breaking capacity 03 5 3.75 0.50 178 140 0.8 Uop min. 0.6 04 6 4.50 0.60 257 140 0.4 05 9 6.75 0.90 579 140 Urel. min. 0.2 06 12 9.00 1.20 1029 140 0 -50-40 -30-20 -100 10 20 30 40 50 60 70 80 90 100110 120 07 24 18.00 2.40 2880 200 Ambient Temperature C All figures are given for coil without pre-energization, at ambient temperature +23C resistive load Coil operating range, standard version 3.4 3.2 140mW coil 3 200mW coil 2.8 Umax. at 2x1A 2.6 2.4 Umax. at 0A 2.2 Umax. at 0A 2 1.8 1.6 DC current A Umax. at 2x2A 1.4 1.2 Unom. nominal coil voltage 1 0.8 All specications subject to change. Consult Tyco Electronics for latest specications. 21 of 28 0.6 0.4 Urel. min. 0.2 0 -50 -40 -30 -20 -10 0102030405060708090 100 110 120 Ambient Temperature C 1 01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section,3.4 available at are subject to change. 3.2 a TE Connectivity Ltd. company 108-98001 Rev. M AXICOMSignalRelays 108-98001 Rev. M AXICOMSignalRelays IM Relay 2 Pole Changeover / 2 Form C / DPDT IM Relay 2 Pole Changeover / 2 Form C / DPDT Signal Relays AXICOM Dimensions Dimensions in mm Dimensions Dimensions in mm IM Relay (Continued) IMTHT IMTHT IMSMT IMSMT IMTHT IMTHT IMSMT IMSMT Standard Narrow GullWings J-Legs Standard Narrow GullWings J-Legs mm inch mm inch mm inch mm inch Coil Data (continued) Insulation Data standard* C* D,P, I mm inch mm inch mm inch mm inch L 10.000.08 0.3930.003 10.000.08 0.3930.003 10.000.08 0.3930.003 10.000.08 0.3930.003 Coil versions, sensitive version, monostable, 1 coil standard, high high current, L 10.000.08W 6.000.080.3930.0030.2360.00310.000.085.700.300.3930.0030.2240.01210.000.086.000.080.3930.0030.2360.00310.000.086.000.080.3930.0030.2360.003 Coil Rated Operate Release Coil Rated coil sensitive, dielectric high contact W 6.000.08 0.2360.003 5.700.30 0.2240.012 6.000.08 0.2360.003 6.000.08 0.2360.003 H 5.650.20 0.2220.008 5.800.08 0.2300.003 5.650.20 0.2220.008 5.650.02 0.2220.008 code voltage voltage voltage resistance power ultra high version stability H 5.650.20 0.2220.008 5.800.08 0.2300.003 5.650.20 0.2220.008 5.650.02 0.2220.008 T 3.2 0.125 3.2 0.125 N/A N/A N/A N/A VDC VDC VDC 10% mW sensitive version T 3.2 0.125 3.2 0.125 N/A N/A N/A N/A T1 N/A N/A N/A N/A 7.500.30 0.2950.011 2.800.20 0.1100.007 11 3 2.40 0.30 91 100 version T1 N/A N/A N/A N/A 7.500.30 0.2950.011 2.800.20 0.1100.007 T2 5.080.10 0.2000.004 3.200.10 0.1260.004 5.080.10 0.2000.004 5.080.10 0.2000.004 12 4.5 3.60 0.45 194 100 Initial dielectric strength T2 5.080.10D1 3.200.150.2000.0040.1260.0063.200.103.200.150.1260.0040.1260.0065.080.103.200.150.2000.0040.1260.0065.080.103.200.150.2000.0040.1260.006 13 5 4.00 0.50 234 100 between open contacts 1000V 1500V 750V D1 3.200.15 0.1260.006 3.200.15rms rms 0.1260.006rms 3.200.15 0.1260.006 3.200.15 0.1260.006 D2 2.200.15 0.0870.006 2.200.15 0.0870.006 2.200.15 0.0870.006 2.200.15 0.0870.006 16 12 9.60 1.20 1315 110 between contact and coil 1800V 1800V 1500V D2 2.200.15Tw 0.40 0.0870.006 0.015 2.200.15rms 0.4rms 0.0870.006rms 0.015 2.200.15 0.4 0.0870.006 0.015 2.200.15 0.4 0.0870.006 0.015 17 24 19.20 2.40 4120 140 Tw between adjacent contacts0.40 0.015 1000V 0.4 1800V 0.015750V 0.4 0.015 0.4 0.015 S 0.75 0.029 rms 0.300.05rms rms0.0110.002 N/A N/A N/A N/A S 0.75 0.029 0.300.05 0.0110.002 N/A N/A N/A N/A Coil versions, ultra high sensitive version, monostable, 1 coil Initial surge withstand voltage Coil Rated Operate Release Coil Rated coil between open contacts 1500V 2500V 1000V 108-98001 Rev. M AXICOMSignalRelays code voltage voltage voltage resistance power between contact and coilTHT Version 2500V 2500V 2000V SMT Version THT Version SMT Version VDC VDC VDC 10% mW between adjacent contacts 1500V 2500V 1000V IM Relay 108-98001 Rev. M AXICOMSignalRelays 21 3 2.55 0.30 180 50 Initial insulation resistance Standard Version Narrow Version Gull Wings J-Legs 9 9 9 22 4.5 3.83 0.45 405 50 between insulated elements >10 >10 >10 Standard Version Narrow Version Gull Wings J-Legs IM Relay 23 5 4.25 0.50 500 50 Capacitance Coil Operating Range 26 12 10.20 1.20 2880 50 between open contacts max. 1pF All figures are given for coil without pre-energization, at ambient temperature +23C between contact and coil max. 2pF Coil Operating Range U = Nominal coil voltage between adjacent contacts max. 2p nom 10.00.08 5.70.3 10.00.08 6.00.08 3.4 50mW coil 10.00.08 6.00.08 10.00.08 6.00.08 Coil operating range, sensitive and ultra high sensitive coil3.2 5.70.3 6.00.08 100mW coil U = Upper limit of the operative range of 10.00.08 6.00.08 10.00.08 max. 10.00.08 6.00.08 10.00.08 *this relay contains SF6 (Sulfur hexafluoride, CAS number: 2551-62-4) for dielectric strength 3 U = Nominal coil voltage nom the coil voltage (limiting voltage) when Umax. at 2x1A 3.4 50mW coilUmax. at 0A 2.8 enhancement, SF6 is hermetically sealed in relay without leaks to air during normal applica- coils are continously energized 3.2 U = Upper limit of the operative range of 100mW coil 2.6 max. tion as recommended per the applicable product specification. It is clarified that the usage 3 2.4 Umax. at 0A the coil voltage (limiting voltage) when Umax. at 2x1A U = Lower limit of the operative range of op. min. of SF6 in mini signal relay is not prohibited by related regulations. Please contact TE local Umax. at 0A 2.8 2.2 0.4 0.4 coils are continously energized 5.080.1 sales or field engineer for further information and detailed material declaration. the coil voltage (reliable operate voltage) 2.6 2 2.80.2 0.4 0.4 0.4 5.080.1 7.50.3 2.4 Umax. at 0A 1.8 0.4 U = Lower limit of the operative range of op. min. For latching relays Uset min. resp. 2.80.2 Umax. at 2x2A 2.2 0.4 7.50.3 1.6 5.080.1 0.4 the coil voltage (reliable operate voltage) Ureset min. 3.20.1 2 1.4 5.080.1 5.080.1 3.20.1 Coplanarity 0.1mm 1.8 For latching relays Uset min. resp. Coplanarity 0.1mm 1.2 U = Lower limit of the operative range of5.080.1 Unom. nominal coil voltageUmax. at 2x2A rel. min. 1.6 Coplanarity 0.1mm 1 Coplanarity 0.1mm RF DataUreset min. the coil voltage (reliable release voltage) Coplanarity 0.1mm Coplanarity 0.1mm 1.4 0.8 Uop min. 1.2 Isolation at 100MHz/900MHz 37.0dB/18.8dB Coplanarity 0.1mm Coplanarity 0.1mm U = Lower limit of the operative range of 0.6 Unom. nominal coil voltage rel. min. 1 0.4 Insertion loss at 100MHz/900MHz 0.03dB/0.33dB the coil voltage (reliable release voltage) 0.8 Urel. min. 0.2 Uop min. Voltage standing wave ratio (VSWR) 0.6 0 Mounting Hole Layout Solder Pad Layout 0.4 -50-40 -30-20 -100 10 20 30 40 50 60 70 80 90 100110 120 at 100MHz/900MHz 1.06/1.49 Mounting Hole Layout Solder Pad Layout Urel. min. 0.2 Ambient Temperature C View onto the component side of the PCB (top view) View onto the component side of the PCB (top view) 0 -50-40 -30-20 -100 10 20 30 40 50 60 70 80 90 100110 120 View onto the component side of the PCB (top view) View onto the component side of the PCB (top view) Ambient Temperature C Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 3.4 Narrow Version Standard Version Gull Wings 3.2 140mW coil Coil versions, standard, bistable 1 coil refer to the Product Compliance Support Center at Narrow Version Gull Wings Standard Version 3 200mW coil Coil Rated Set Reset Coil Rated coil www.te.com/customersupport/rohssupportcenter 3.42.8 Umax. at 2x1A 3.22.6 140mW coil code voltage voltage voltage resistance power Ambient temperature -40C to +85C 2.43 Umax. at 0A 200mW coil VDC VDC VDC 10% mW Thermal resistance <150K/W 2.8 2.2 Umax. at 2x1A Umax. at 0A 2.6 40 1.52 1.13 -1.13 23 100 Category of environmental protection 2.4 1.8 Umax. at 0A 48 2.4 1.80 -1.80 58 100 IEC 61810 RT V - hermetically sealed 2.2 1.6 Umax. at 2x2A Umax. at 0A 2 41 1.43 2.25 -2.25 90 100 Vibration resistance (functional) 20g, 10 to 500Hz 1.81.2 Unom. nominal coil voltage 42 4.5 3.38 -3.38 203 100 Shock resistance (functional), half sinus 11ms 50g 1.61 Umax. at 2x2A 1.40.8 43 5 3.75 -3.75 250 100 Shock resistance (destructive), half sinus 0.5ms 500g 1.2 0.6 Unom. nominal coil voltage 44 6 4.50 -4.50 360 100 Mounting position any 1 0.4 Urel. min. 0.8 45 0.29 6.75 -6.75 810 100 Weight max. 0.75g min.0.75 min.0.75 0.6 0 min.0.75 46 12 9.00 -9.00 1440 100 Resistance to soldering heat SMTmin.0.75 0.4 -50 -40 -30 -20 -10 0102030405060708090 100 110 120 Urel. min. 47 0.224 18.00 -18.00 2880 200 IEC 60068-2-58 Ambient Temperature C 0 All figures are given for coil without pre-energization, at ambient temperature +23C Moisture sensitive level, JEDEC J-Std-020D MSL3 -50 -40 -30 -20 -10 0102030405060708090 100 110 120 related only to SMT relays Ambient Temperature C Terminal Assignment Coil operating range, bistable 1 coil packed in orginal dry-packs Terminal Assignment 3.4 3.2 Relay top view Ultrasonic cleaning not recommended 3 Relay top view Umax. - 5%coil 3.4 Packaging/unit 2.8 Umax.-5%coil duty at 3.2 2.6 duty at 0A(100mW) 2x2A (100mW) T erminal assignmentTHT version tube/50pcs., box/1000 pcs. Umax. - 100% coil duty at Latching Type, 1 Coil 3 2.4 Non-Latching Type 0A (100mW) Umax. - 5%coil TOP view on r SMT versionelay r eel/1000 pcs., box/1000 or 5000 pcs. 2.8 Latching Type, 1 Coil 2.2 duty at UUmaxmax.-5%coil.-5%coil Non-Latching Type 2.6 2x2A (100mW) duty at 0A(100mW)duty at 0A (200mW) 2 Umax. - 100% coil duty at Monostable version Bistable version, 1 coil reset condition 2.4 0A (100mW) not energized condition Umax. - 100% coil duty at 1.8 rest condition reset condition 0A (200mW) reset condition 2.2 Umax.-5%coil not energized condition 1.6 Umax. -5% coil duty at 0A (200mW) 2 1.4 duty at 2x1A (100mW) Umax. - 100% coil duty at 1.8 1.2 0A (200mW) 1.6 Umax. -5% coil 1 Unom. nominal coil voltage duty at 2x1A (100mW) 1.4 0.8 1.2 Uset min. 0.6 1 Unom. nominal coil voltage 0.4 100 mW Latching 0.8 0.2 200 mW Latching Uset min. 0.6 0 Contacts inreset position. Contact 0.4 -50-40 -30-20 -100 10 20 30 40 50 60 70 80100 mW Latching90 100 110 120 130 140 Contacts inreset position. Contact 0.2 200 mW Latching positionmightchangeduringtrans- Ambient Temperature C 0 positionmightchangeduringtrans- -50-40 -30-20 -100 10 20 30 40 50 60 70 80 90 100 110 120 130 140 portationandmustberesetbefore portationandmustberesetbefore Ambient Temperature C use. Contacts are shown in reset condition. Contact position might change during use. transportation and must be reset before use. All specications subject to change. Consult Tyco Electronics for latest specications. 24 of 28 All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 28 2 All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 28 01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - All specications subject to change. Consult Tyco Electronics for latest specications. 24 of 28 www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company