Note: All part numbers AMP Circular Connectors for are RoHS Compliant. Commercial Signal and Power Applications Circular Plastic Connector Sealing Accessories A Sealing Caps for Receptacles only .015 B 0.38 Sealing caps are used to protect exposed contacts of unmated .030 3.000 0.76 receptacles. 76.2 .143 Dia. 3.63 Material and Finish Plastic Strap CapThermoplastic, heat stabilized, fire resistant, self-extinguishing, 94V-1 rated, black Dimensions Shell Plastic Strap Metal Bead Chain Series Size Part No. Part No. A B Sealing GasketNeoprene, black .360 .927 Bead ChainSteel, nickel plated 11 1 & 2 206903-1 208800-1 9.14 23.55 Bead Chain CouplingBrass, plated .360 1.055 13 1 211870-1 213485-1 nickel 9.14 26.80 .360 1.295 17 1,2,& 3 207445-1 208652-1 9.14 32.89 1, 3, & 4 207446-1 208680-1 .460 1.728 23 11.68 43.89 2 207446-2 208680-2 A Min. Cable Entry Seals Heat Shrinkable Sealing Boots Jacketed Cable Cable entry seals are used with B Dia. Min. jacketed cable to provide an environmentally sealed wire-to- connector system. They can be used Expanded Sealing Max. Recovered Dimensions Shell Part Wall Range Inside with either plugs or receptacles. Size No. A B Thickness (Dia.) Diameter .160 54010-4 2.500 .625 .050 Ref250 - .600 4.06 Thick Wall Boots 11 63.50 15.88 1.27 Ref. 6.35 - 15.24 .250 54010-1 6.35 Ref250 - .375 .220 54123-2 Material 6.35 - 9.53 5.59 2.500 .775 .060 Ref. 13 63.50 19.68 1.52 Internal SleeveNylon .375 - .725 .300 54123-1 9.53- 18.42 7.62 Outer TubingPolyolefin, black 2.500 ef. 54011-1 63.50 .975 .060 Ref400 - .875 .375 Ref. 17 24.76 1.52 10.16 - 22.22 9.52 3.000 . 54011-3 76.20 3.000 1.250 .070 Ref550 - 1.250 .500 23 Ref. 54012-1 76.20 31.75 1.78 13.97 - 31.75 12.70 Threaded Sleeve 15/16-20 UNEF 38 THD Thin Wall Boot Tubing with Sealant .015 1.027 .625 Material 0.38 26.09 15.88 Dia. Dia. Inter SleeveNylon Outer TubingPolyolefin Expanded Wall Thickness .010 .875 .020 0.51 0.25 22.22 .025 2.000 Max. Recovered Wall Thickness 0.64 50.80 .040 10.16 Sealing Range.250 6.35 - .500 12.70 Dia. Shell Size 17 Part No. 213933-1 52 Catalog 82021 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000 Revised 7-07 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341 CPC Sealing AccessoriesCPC Sealing Accessories Note: All part numbers AMP Circular Connectors for are RoHS Compliant. Commercial Signal and Power Applications Circular Plastic Connector Sealing Accesories (Continued) .030 3.500 Jacketed Cable Seals 0.76 88.9 (for Shell Size 23) A jacketed cable seal kit provides an environmentally sealed connection +.000 0.15 for jacketed cable. 1.095 1.290 0.38 27.81 32.77 Dia. Dia. Material Peripheral SealGrey elastomer See Sealing Range (Dia.) CollarAluminum Female Jacketed Cable SealBlack rubber Back-Shell ExtenderBlack glass-filled thermoplastic Special Clamp SaddleBlack Special thermoplastic Clamp Saddle Note: Jacketed cable seals must be Plug used with large cable clamps and (See Note) can be used on plugs or receptacles. Jacketed Large cable clamps are to be Cable Seal* ordered separately (see page 38). Each jacketed cable seal kit Collar includes: Peripheral Sealto be Back-Shell Extender discarded if kit is used on plug. Large Cable Clamp Additional seals may be Sealing Part No. 206512-5 Kit purchased (see page 51) Range (See Note) Number Collarprovides bearing surface (Dia.) for back-shell extender .300-.450 207052-1 Jacketed Cable Seal 7.62-11.43 *Jacketed cable seal is pressed flush against rear Back-Shell Extender .450-.600 connector face when back-shell extender is threaded 207052-2 Special Clamp Saddleto be 11.43-15.24 onto rear of connector. used in lieu of clamping insert .600-.875 supplied with large cable clamp 207052-3 15.24-22.22 .020 Rubber Boot 1.800 0.51 45.72 Rubber boots are used with .010 B 0.25 jacketed cable to provide splash- proof connections for Series 1 and Series 3 connectors010 D C A 0.25 (Not for Metal Shell Connectors.) Material Black neoprene Rubber Boot Plug (See Note 1) Jacketed Cable Dimensions Shell Cable Dia. Part Size Sealing Range No. AB C D .219-.438 .750 .300 .600 .170 11 206304-1 5.56-11.13 19.05 7.62 15.24 4.32 Notes: 1. Rubber boots are recommended for use with jacketed cable and can be used on plugs or receptacles, except Series 2 connectors. Notes: 2. For detailed performance data on rubber boots, refer to Product Specification No. 108-10024. 53 Catalog 82021 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000 Revised 7-07 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341