44B5121
SPECIFICATION CONTROL DRAWING
Date Revision
TITLE
TWO CONDUCTOR CABLE, SPIRALLY SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 4-20-07 H
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
JACKET - RADIATION-CROSSLINKED,
SHIELD - TIN-COATED COPPER
COMPONENT WIRES - 44A0111
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
JACKET THICKNESS OUTSIDE DIAMETER
CONDUCTOR SHIELD MAXIMUM
PART NUMBER
(in.) (in.)
SIZE SIZE WEIGHT
1/
(AWG) (AWG) (lbs/1000 ft.)
MINIMUM NOMINAL NOMINAL MAXIMUM
44B5121-24-* 24 36 .006 .008 .107 .112 9.5
44B5121-22-* 22 36 .006 .008 .121 .127 12.4
44B5121-20-* 20 36 .006 .008 .137 .144 16.4
44B5121-18-* 18 36 .006 .008 .157 .165 22.4
44B5121-16-* 16 36 .006 .008 .171 .180 27.1
44B5121-14-* 14 36 .006 .008 .205 .215 39.3
44B5121-12-* 12 36 .007 .009 .245 .257 58.0
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150C LIFE CYCLE: 200 3C for 168 hours
Maximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours
VOLTAGE RATING: 600 volts (rms) at sea level SHIELD COVERAGE: 85% (minimum)
ACCELERATED AGING: 300 3C for 7 hours VOLTAGE WITHSTAND TEST (Post Environmental):
BLOCKING: 150 3C for 6 hours 1000 volts (rms), 60 Hz, 1 minute
DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute
FLAMMABILITY (Procedure 1): 3 seconds (maximum); PART NUMBER:
3 in. (maximum); no flaming of facial tissue The * in the part numbers above shall be replaced by color code
JACKET COLOR: White preferred designators with a slash separating the component wire colors and a
JACKET ELONGATION AND TENSILE STRENGTH: dash separating the component wire colors from the jacket color.
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in (minimum) 1/ Example: AWG 20, black and brown component wires; white jacket:
JACKET FLAWS: 44B5121-20-0/1-9
Spark Test, 1.0 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
R Wire & Cable
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
501 Oakside Avenue
Redwood City, CA 94063-3800
Page 1 of 1
Phone: 1-800-227-8816
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
Fax: 1-650-361-6297
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2007 Tyco Electronics Corporation. All rights reserved.X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Multi-Conductor Cables category:
Click to view products by TE Connectivity manufacturer:
Other Similar products are found below :
89182-010-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6300FE-877-U1000 6309UE-877-1000 M3905-BK005
6502FE 8771000 6541PA-008-U1000 CV6807-000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-
0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000
82841-877-5000 83318E-009-500 8348-060-500 83559-002-1000 83653-002-5000 83659-002-1000 83709-002-1000 8404-060-500 8469
060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769-060-1000 8775-060-
500 877541-000 8780-060-1000 8782-001-U1000 88444-002-1000 9159-060-500 9318-060-1000 939870-000 9423 060U500 9444
060U1000