GENERALPURPOSERELAY FEATURES: TYPE 156 High reliability / Long life. AC & DC coil. Epoxy sealed type available. Multiple options available. Contact rating 5A 240VAC resistive load. PCB mount and plug-in.. Type 2 Pole 4 Pole Resistive Load 5A/28VDC 5A/28VDC General use 5A/240VAC 5A/240VAC Rated Current Max.Continuous Rated Voltage Coil Resistance Pickup Voltage Dropout Voltage Power Consumption (V) 10% at 25C 10% at 25C Voltage at 25C (Max) at 25C (Min) at 25C at Rated Voltage (mA) (W) 6 150 40 75 12 160 110% of 75% of 10% of Approx. 0.9 W 24 37 650 rated voltage rated voltage rated voltage 48 19 2600 110 10 11000 Power Max.Continuous Pickup Voltage Dropout Voltage Rated Voltage Coil Resistance Consumption 10% at 25C (W) Voltage at 25C (Max) at 25C (Min) at 25C (V) at Rated Voltage 12 40 160 110% of 85% of 30% of Approx. 24 rated voltage rated voltage 240 3400 rated voltage 1.2 VA 220 13600 Relay Type Enclosure & Terminals Contact Form Coil Voltage Contact Material & Ratings Standard or Special 1Dust Cover/Solder Lug/3-48 13/32Silver 00Standard G5VDC 156 2DPDT Stud (Gold Flash) C0Push Button A6VDC 44PDT 2Dust Cover/PCB 23/32Silver LCLamp & Push Button B12VDC 3Dust Cover/Solder Lug/3-48 L0Lamp Across Coil C24VDC Cadmium Oxide Stud/Sealed.* 73/32Silver Gold D48VDC 5Dust Cover/Solder Diffused F110VDC Lug/Sealed* P12VAC 6Flanged Cover/Solder Lug Q24VAC 7Dust Cover/PCB/Sealed T120VAC Consult Factory For Any U240VAC Specials *Sealed, 4PDT only Example:156-14C200 Stock item: 156-12B200, 156-12C200, 156-12T200, 156-12Q200, 156-12U200, 156-14B200, 156-14C200, 156-14T200, 156-14Q200, 156- 24B200, 156-24T200, 156-62B200, 156-62C200, 156-62T200, 156-62Q200. Libertyville IL (847) 680-7400 FAX (847) 680-8169 www.ciitech.com 9TYPE 156 Contact resistance 50 m Max. (initial value) Operate time 25 mS Max. Release time 25 mS Max. Insulation resistance 100 M Min. (DC 500V) Between open contact:AC 500V 50/60 Hz 1 minute. Dielectric strength Between contact and coil:AC1500V 50/60 Hz 1 minute. Between contact circuits:AC 1500V 50/60 Hz 1 minute. Vibration resistance Damage limits & Operating extremes:10~55 Hz, amplitude 1.0 mm Shock resistance Damage limits:100g, Operating extremes:20g Life expectancy for mechanical 10,000,000 operations (frequency 18,000 operations/hr) Life expectancy for electrical 100,000 operations (frequency 1,800 operations/hr) Operating temperature -25~+55 C (no freezing) W eight Approx. 35g 2 Pole 2 Pole 4 Pole 4 Pole Inches (Millimeters) 10 Libertyville IL (847) 680-7400 FAX (847) 680-8169 www.ciitech.com