SPECIFICATION CONTROL DRAWING 1726A1424
Date 4-16-09
120 OHM, AWG 26, 7 STRANDS OF AWG 34,
CHEMINAX
RADIO FREQUENCY, TWINAXIAL CABLE
Revision F
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
CHARACTERISTIC IMPEDANCE 120 12 ohms, Method D at 700 kHz - 1 MHz
110 10 ohms, Method D at 1 MHz - 20 MHz
MUTUAL CAPACITANCE 13.72 pF/ft. (maximum)
CONDUCTOR
VELOCITY OF PROPAGATION 77% (nominal)
AWG 26, 7 Strands of
.019
AWG 34, Silver-Coated
ATTENUATION 3 dB/100 ft. (maximum) at 1 MHz
High Strength Copper
8 dB/100 ft. (maximum) at 5 MHz
Alloy
.047
SURFACE TRANSFER IMPEDANCE 50 milliohms/m (maximum) at 0.1 MHz
DIELECTRIC
50 milliohms/m (maximum) at 1 MHz
Rayfoam H
Color - White/Light Blue
50 milliohms/m (maximum) at 10 MHz
.031
FILLERS
100 milliohms/m (maximum) at 30 MHz
FEP
CAPACITANCE UNBALANCE 3.5% (maximum)
ADDITIONAL REQUIREMENTS
ELECTRICAL
CONDUCTOR RESISTANCE 43.9 ohms/1000 ft. (nominal)
INSULATION RESISTANCE 10,000 megohms (minimum)
SHIELD
(CONDUCTOR TO SHIELD) for 1000 ft.
.107
AWG 40,
Silver-Coated Copper
JACKET FLAWS
Optimized
SPARK TEST 1.0 kV (rms)
IMPULSE TEST 6.0 kV (peak)
VOLTAGE WITHSTAND (DIELECTRIC) 1000 volts (rms) (minimum)
ENVIRONMENTAL
FLAMMABILITY Method B
HEAT SHOCK 225C
JACKET
.123
Modified FEP
LOW TEMPERATURE-COLD BEND -55C/3.50 inch mandrel
.006
VOLTAGE WITHSTAND 1000 volts (rms), 1 minute
(Post Environmental)
PHYSICAL
INSULATION (DIELECTRIC)
(Prior to Cabling)
ELONGATION 50% (minimum)
2
TENSILE STRENGTH 600 lbf/in (minimum)
JACKET
ELONGATION 200% (minimum)
2
Outer jacket color will be translucent white (designated by a TENSILE STRENGTH 2000 lbf/in (minimum)
-9 appended to the part number, e.g. 1726A1424-9X) unless
JACKET THICKNESS .008 inch (nominal)
otherwise specified.
SHIELD COVERAGE 90% (minimum)
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and suffixes may be added to
the part number, as necessary, to capture any additional
requirements imposed by the purchase order.
WEIGHT 12.2 lbs/1000 ft. (nominal)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also
reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer .
Page 1 of 1 The TE logo, Tyco Electronics, Cheminax, Raychem and Rayfoam are trademarks.
Raychem Wire & Cable
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS
501 Oakside Avenue
Redwood City, California 94063-3800 REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE
1-800-227-8816 Fax: 1-650-361-6297
ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2006-2009 Tyco Electronics Corporation. All rights reserved.X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Multi-Conductor Cables category:
Click to view products by TE Connectivity manufacturer:
Other Similar products are found below :
89182-010-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6300FE-877-U1000 6309UE-877-1000 M3905-BK005
6502FE 8771000 6541PA-008-U1000 CV6807-000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-
0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000
82841-877-5000 83318E-009-500 8348-060-500 83559-002-1000 83653-002-5000 83659-002-1000 83709-002-1000 8404-060-500 8469
060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769-060-1000 8775-060-
500 877541-000 8780-060-1000 8782-001-U1000 88444-002-1000 9159-060-500 9318-060-1000 939870-000 9423 060U500 9444
060U1000