Application Specification FASTON* Straight Receptacles 114-2036 with F- Crimp Feature 17 AUG 12 Rev F All numerical values are in metric units with U.S. customary units in brackets . Dimensions are in millimeters and inches . NOTE Unless otherwise specified, dimensions have a tolerance of 0.13 mm .005 in. and angles have a tolerance of 2. Figures and illustrations are for identification only and are not drawn to scale. i 1. INTRODUCTION This specification covers the requirements for application of FASTON Straight Receptacles with the F-Crimp wire barrel feature. Receptacles are available in a variety of mating configurations, and in five series sizes: .312, .250, .205, .187, and .110. The series designates the width of the mating tab. Also, depending on series and mating end, receptacles are offered in many standard tab thicknesses. When corresponding with TE Connectivity Personnel, use the terminology provided in this specification to facilitate your inquiries for information. Basic terms and features of this product are provided in Figure 1. Serrated Wire Barrel Insulation Support Barrel Large Flared Lead-In Premier with Insulation Support Economy with Insulation Support Insulation Support Barrel Low Insertion Force (LIF) Serrated Wire Barrel with Insulation Support Mating Tab Retention Feature (Detent) Receptacles without Insulation Support Split-Roll Feature Cantilevered Dual-Slotted Floor Design Figure 1 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company TOOLING ASSISTANCE CENTER 1-800-722-1111 This controlled document is subject to change. 1 of 12 All Rights Reserved PRODUCT INFORMATION 1-800-522-6752 For latest revision and Regional Customer Service, *Trademark visit our website at www.te.com TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks of their respective owners. 114-2036 2. REFERENCE MATERIAL 2.1. Revision Summary Updated document to corporate requirements Added new NOTE to Section 5, TOOLING 2.2. Customer Assistance Reference Product Base Part Number 41202 and Product Code 1110 are representative of FASTON Straight Receptacles with F- Crimp Feature. Use of these numbers will identify the product line and help you to obtain product and tooling information. Such information can be obtained through a local TE Representative, by visiting our website at www.te.com, or by calling PRODUCT INFORMATION or the TOOLING ASSISTANCE CENTER at the numbers at the bottom of page 1. 2.3. Drawings Customer drawings for each product part number are available from a service network. The information contained in customer drawings takes priority if there is a conflict with this specification or with any technical documentation supplied by TE. 2.4. Specifications The following Application Specifications provide information for the application of related products. Document Number Document Title 114-2028 FASTON 110 Series Flag Receptacles 114-2032 FASTON Reversible Flag Receptacles 114-2070 FASTON AMPLIVAR* Contact Tab 114-2078 FASTON Flag Receptacles with Tab Lok Feature 114-2079 FASTON Flag Receptacles with F- Crimp Feature 114-2082 FASTON Piggyback Receptacles 114-2126 FASTON F- Crimp Center-Strip Flag Receptacles 2.5. Instructional Material The following list includes available instruction sheets (408-series) that provide assembly procedures for operation, maintenance and repair of tooling and customer manuals (409-series) that provide setup, operation, and maintenance of machines. A variety of Instruction Sheets for FASTON products are available from TE. Contact the Product Information Center number at the bottom of page 1. Document Number Document Title 408-3295 Preparing Reel of Contacts for Applicator Tooling 408-7424 Checking Contact Crimp Height 408-7432 Force Gage 92-100505 408-8039 Heavy Duty Miniature Quick-Change Applicators (End-Feed Type) 408-8040 Heavy Duty Miniature Quick-Change Applicators (Side-Feed Type) 408-8053 Miniature (Mini) and Quick-Change Applicators 408-8059 General Preventative Maintenance for Applicators 408-9816 Handling of Reeled Products 409-5842 AMP-O-LECTRIC* Model G Terminating Machine 354500- 409-5852 AMPOMATOR* CLS III-G Lead-Making Machine 122500- 409-5878 AMPOMATOR CLS IV+ Lead-Making Machine 356500- 409-10027 Stripping Modules 1490500 and 1490502 409-10029 Stripping Modules 1490501 and 1490503 409-10047 AMP 3K* Terminating Machines 1725950-3, -4 3. REQUIREMENTS 3.1. Storage A. Ultraviolet Light Prolonged exposure to ultraviolet light may deteriorate the chemical composition used in the contact materials. Rev F 2 of 12