55A7226 SPECIFICATION CONTROL DRAWING Date Revision TITLE THREE CONDUCTOR CABLE, JACKETED, GENERAL PURPOSE, 600 VOLT 4-2-06 A This specification sheet forms a part of the latest issue of Raychem Specification 55A. JACKET - RADIATION-CROSSLINKED, COMPONENT WIRES - 55A0213 MODIFIED ETFE FILAMENT STRIPPING THREAD - NOMEX, 200/I/4E, No finish CONSTRUCTION DETAILS OUTSIDE DIAMETER CONDUCTOR JACKET THICKNESS MAXIMUM PART NUMBER (inches) SIZE WEIGHT (inches) 1/ (AWG) (lb/1000 ft) MINIMUM NOMINAL NOMINAL MAXIMUM 55A7226-22-* 22 .006 .008 .113 .119 11.6 55A7226-20-* 20 .006 .008 .130 .137 16.8 55A7226-18-* 18 .006 .008 .152 .160 24.1 55A7226-16-* 16 .006 .008 .169 .178 30.3 55A7226-14-* 14 .006 .008 .206 .216 45.5 55A7226-12-* 12 .007 .009 .247 .259 67.8 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C LIFE CYCLE: 230 3C for 500 hours Maximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 3C for 4 hours VOLTAGE RATING: 600 volts (rms) ACCELERATED AGING: 300 3C for 7 hours BLOCKING: 200 3C for 6 hours PART NUMBER DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz The in the part numbers above shall be replaced by FLAMMABILITY: color code designators with a slash separating the Procedure 1, 3 seconds (maximum) 3 inch (maximum) component wire colors and a dash separating the no flaming of facial tissue component wire colors from the jacket color. Colors shown JACKET COLOR: White preferred do not necessarily reflect the sequence of manufacturing. JACKET ELONGATION AND TENSILE STRENGTH: 1/ Example: AWG 20, black, red and orange component wires Elongation, 50% (minimum) white jacket: 55A7226-20-0/2/3-9 Tensile Strength, 5000 lbf/in (minimum) NOTE: Nominal values are for information only. Nominal values are not requirements NOMEX is a registered trademark of E.I. du Pont de Nemours and Company. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297 2006 Tyco Electronics Corporation. All rights reserved.X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89182-010-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6300FE-877-U1000 6309UE-877-1000 M3905-BK005 6502FE 8771000 6541PA-008-U1000 CV6807-000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA- 0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 82841-877-5000 83318E-009-500 8348-060-500 83559-002-1000 83653-002-5000 83659-002-1000 83709-002-1000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769-060-1000 8775-060- 500 877541-000 8780-060-1000 8782-001-U1000 88444-002-1000 9159-060-500 939870-000 9423 060U500 9444 060U1000 9497 0001000