SPECIFICATION CONTROL DRAWING
2022H4424
Date: 9-22-06
120 OHM, AWG 22, 19 STRANDS OF AWG 34
RADIO FREQUENCY, TWIN CONDUCTOR CABLE
CHEMINAX Revision: C
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
CHARACTERISTIC IMPEDANCE 120 10 ohms, Method D at 1 MHz
DESIGNATED.
CAPACITANCE - MUTUAL 12.7 pF/ft. (nominal)
CONDUCTORS
18.2 pF/ft. (maximum)
AWG 22, 19 Strands of
.0295
AWG 34, Silver-Coated
VELOCITY OF PROPAGATION 77% (nominal)
High Strength Copper Alloy
DIELECTRICS
.077
Rayfoam H
Color - Light Blue/White
ADDITIONAL REQUIREMENTS
.052
FILLERS
Radiation-Crosslinked
ELECTRICAL
Modified ETFE
CONDUCTOR RESISTANCE 17.3 ohms/1000 ft. (nominal)
INSULATION RESISTANCE 10,000 megohms (minimum)
for 1000 ft.
JACKET FLAWS
SPARK TEST 1.0 kV (rms)
IMPULSE TEST 6.0 kV (peak)
VOLTAGE WITHSTAND
(DIELECTRIC) 1500 volts (rms) (minimum)
1ST SHIELD
.161
Flat, .0015 inch thickness
Tin-Coated Copper
ENVIRONMENTAL
FLAMMABILITY Method B
HEAT SHOCK 225C
LOW TEMPERATURE- -55C/5.50 inch mandrel
COLD BEND
2ND SHIELD
.178 VOLTAGE WITHSTAND
AWG 38
(POST ENVIRONMENTAL) 1000 volts (rms), 1 minute
Tin-Coated Copper
PHYSICAL
INSULATION (DIELECTRIC)
(Prior to Cabling)
ELONGATION 50% (minimum)
JACKET TENSILE STRENGTH 600 lbf/in (minimum)
.192
Modified FEP
JACKET
ELONGATION 200% (minimum)
TENSILE STRENGTH 2000 lbf/in (minimum)
1st SHIELD COVERAGE 92% (minimum)
2nd SHIELD COVERAGE 90% (minimum)
JACKET THICKNESS .007 inch (nominal)
Outer jacket color will be white (designated by a-9" appended
to the part number, e.g., 2022H4424-9) unless otherwise specified.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and suffixes may be added to the
part number, as necessary, to capture any additional requirements
imposed by the purchase order.
WEIGHT 28.3 lbs/1000 ft. (nominal)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
501 Oakside Avenue
R
Redwood City, California 94063-3800 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Wire & Cable
1-800-227-8816 Fax: 1-650-361-6297
2006 Tyco Electronics Corporation. All rights reserved.