SPECIFICATION CONTROL DRAWING 2026H242A 11-17-16 Date: 120 OHM, AWG 26, 19 STRANDS OF AWG 38, TWINAXIAL CABLE CHEMINAX C Revision: THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS CHARACTERISTIC IMPEDANCE 120 12 ohms, Method D at 1 MHZ OTHERWISE DESIGNATED. with shield grounded MUTUAL CAPACITANCE 12.7 pF/ft. (nominal) 18.2 pF/ft. (maximum) CONDUCTORS VELOCITY OF PROPAGATION 77% (nominal) AWG 26, ATTENUATION 1.1 dB/100 ft. (maximum) at 1 MHz 19 Strands of AWG 38, 2.4 dB/100 ft. (maximum) at 6 MHz .0194 Silver-Coated Ultra High- 3.1 dB/100 ft. (maximum) at 10 MHz Strength Copper Alloy 8.6 dB/100 ft. (maximum) at 100 MHz .051 DIELECTRICS (nominal) Foamed FEP .053 ADDITIONAL REQUIREMENTS Colors - Light Violet/White (maximum) FILLERS .034 Radiation-Crosslinked, ELECTRICAL Modified ETFE CONDUCTOR RESISTANCE 56.4 ohms/1000 ft. (nominal) (prior to cabling) INSULATION RESISTANCE 10,000 megohms (minimum) for 1000 ft. JACKET FLAWS SPARK TEST 1.0 kV (rms) IMPULSE TEST 6.0 kV (peak) SHIELD Flat, VOLTAGE WITHSTAND (DIELECTRIC) 1500 volts (rms) (minimum) .109 .0015 Strand Thickness, Tin-Coated Copper ENVIRONMENTAL FLAMMABILITY Method B HEAT SHOCK 225C LOW TEMPERATURE-COLD BEND -55C/3.50 inch mandrel VOLTAGE WITHSTAND 1000 volts (rms), 1 minute (Post Environmental) .123 JACKET (nominal) PHYSICAL Modified FEP .129 (maximum) INSULATION (DIELECTRIC) (prior to cabling) ELONGATION 50% (minimum) 2 TENSILE STRENGTH 600 lbf/in (minimum) JACKET ELONGATION 200% (minimum) 2 TENSILE STRENGTH 2000 lbf/in (minimum) JACKET THICKNESS .007 inch (nominal) SHIELD COVERAGE 92% (minimum) Designate outer jacket color with a dash number in accordance with MIL-STD-681. Unless otherwise specified, outer jacket color WEIGHT 11.1 lbs/1000 ft. (nominal) will be translucent white designated by a-9 appended to the part number, (e.g. 2026H242A-9X). ENGINEERING REFERENCE Other codes and suffixes may be added to the part number, as TEMPERATURE RATING 150C (maximum) necessary, to capture any additional requirements imposed by the purchase order. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 1 Cheminax, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. 501 Oakside Avenue REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Redwood City, California 94063-3800 2013-2016 Tyco Electronics Corporation. All rights reserved. Phone: 1-800-522-6752 Fax: 1-650-361-6297 X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 8916-GRY-100 8918-GRN/YEL-100 8920-BRN-1000 8920-RED-1000 89907-LT-DEC/GRY-500 CR3909-000 CR3927-000 01342.35T.01 01364.35T.01 003201-000 CS2885-000 CS8782-000 CS9912-000 6200UE-NAT-U1000 CTC-0062-20-9/5-9 CTC-0062-22-9/5-9 6304FE- 877-U500 6309UE-877-1000 6320UE-NAT-U1000 644833-000 6502FE 8771000 6504UE-877-U1000 CW9530-000 CX6543-000 CXA- 0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660- 000 706/2R-BLACK-EACH 720451-000 730859-000 MCC-USB-4-250 752687-000 768146-000 773159-000 7934A-BLK-1000 8125- CHR-100 8164-CHR-1000 820457-000 8205-CHR-1000 8240-BLK-U1000 82723-NAT-1000 82907-NAT-500 83003-YEL-500 83005- WHT-500 83006-DK-GRN-100 83008-WHT-1000 83009-BLK-100