108-130001 Product 11 MAY 2021 Rev H Specification STRADA Whisper Cable Assembly 1. SCOPE 1.1. Content This specification defines performance, tests and quality requirements for 100 PiR STRADA Whisper Cable Assemblies. Properties specific to the board mount connector are covered by STRADA Whisper Connector system specifications 108-32021 and 108-32112. 1.2. Qualification Testing When tests are performed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using applicable inspection plan and product drawings. Successful qualification testing on the STRADA Whisper Cable Assembly product was completed on January 31, 2020. The Qualification Test Report number for testing is 501-134100. Additional mixed flowing gas testing is documented in test report EA20200151T. 2. APPLICABLE DOCUMENTS The following documents and forms constitute a part of this specification to the extent specified herein. Unless otherwise indicated, the latest edition of the document applies. In the event of conflict between the 2.1. TE Documents 108-32021: Product Specification (3.9 STRADA Whisper Connector System) 108-32112: Product Specification (3.9 STRADA Whisper Connector System No Pd/Ni) 501-134100: Qualification Test Report EA20200151T: Engineering Test Report (mixed flowing gas test sequence)- Cabled Header EA20210085T: Engineering Test Report (mixed flowing gas test sequence)- Cabled Receptacle 2.2. Industry Standard EIA-364 Electrical Connector/Socket Test Procedures including Environmental Classifications 2.3. Reference Document 109-197 Test Specification (AMP Test Specifications vs. EIA and IEC Test Methods) 3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction, materials and physical dimensions specified on the applicable product drawings. 3.2. Ratings Voltage: 80 volts AC maximum peak (1/3 of minimum withstanding voltage) Current: See Figure 2 Temperature: -55 to +85 degrees Celsius 2021 TE Connectivity family of companies This controlled document is subject to change. 1 of 5 All Rights Reserved For latest revision and Regional Customer Service, visit our website at www.te.com Indicates Change PRODUCT INFORMATION 1-800-522-6752 *Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners. 108-130001 3.3. Test Requirements and Procedures Summary Unless otherwise specified, all tests shall be performed at ambient environmental conditions. Test Description Requirement Procedure EIA-364-18. Visual and dimensional Meets product drawing Initial Examination (CofC) inspection per product requirements. drawing. Final Examination Meets visual requirements. EIA-364-18. Visual Inspection. ELECTRICAL R 10 milliohms maximum for EIA-364-23. Subject specimens to Low Level Contact individual signal reading and R 100 milliamps maximum and 20 Resistance (LLCR) 250 milliohms maximum for millivolts maximum open circuit individual ground reading final. voltage. See Figure 3 EIA-364-21. 100 volts DC, 2 minute Insulation Resistance 1000 megaohms minimum hold. Test between adjacent contacts of mated specimens. EIA-364-20, Condition I. 250 volts AC at sea level. Test between One minute hold with no Withstanding Voltage adjacent contacts and signal breakdown or flashover. contacts to ground of mated specimens. 30C maximum temperature EIA-364-70, Method 1. Stabilize at a Temperature Rise VS. rise at the current ratings shown single current level until 3 readings at Current in Figure 2. 5 minute intervals are within 1C. MECHANICAL EIA-364-13. Measure force 2.10 N .47 lb maximum average necessary to mate specimens at a Mating Force per differential pair including maximum rate of 12.7 mm .5 in per ground. minute. EIA-364-13. Measure force 0.31 N .07 lb minimum average necessary to unmate specimens at a Unmating Force per differential pair including maximum rate of 12.7 mm .5 in per ground. minute. Measure force necessary to pull the 44.5 N 10 lb minimum per cablet out of the housing at a Cablet Retention cablet. maximum rate of 12.7 mm .5 in per minute. EIA-364-9. Mate and unmate No physical damage and post specimens for 200 cycles at a Durability testing LLCR. See note maximum rate of 600 cycles per hour. Rev H 2 of 5