Model 96 - 3100 series Definite Purpose Contactor 1- or 2-pole, 20-40 FLA AC Coil File E75492 File EN60947-4-1:2010 EN60947-1:2007 File LR49598 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features Environmental Data Temperature Range: Storage and Operating: -40C +65C. Robust 1- and 2-pole contactors. Shunt available on 1-pole models. Flammability: UL 94-HB housing. Convenient mounting plate. Mechanical Data Contact Termination: 20, 25, 30 FLA Models Type: 10-32 Screw with quad 0.250 (6.35 mm) quick connects. Contact Data 25C Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.) Arrangements: 1 Form X (SPST-NO-DM) with or without shunt and Tightening Torque: 25 in.-lbs. 2 Form X (DPST-NO-DM). NOTE: Contactors with terminals of two-piece design are shipped Maximum Ratings: See Contact Ratings Table. with terminal screws left up to facilitate customer wiring. The Material: Silver Cadmium Oxide. customer must tighten the screws to the specified torque to achieve a good electrical connection. 40 FLA Models Type: Box Lug with dual 0.250 (6.35 mm) quick connects. Coil Data 25C Wire Size: 14-4 Cu/Al AWG Voltage: 24 - 277 VAC, 50/60 Hz. See Coil Data Table below. Tightening Torque: 40 in.-lbs. (480 & 575VAC coils available upon request.) Coil Termination: Dual 0.250 (6.35 mm) quick connects. Insulation Class: UL Class B (130C). Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models. Duty Cycle: Continuous. Weight: One Pole Types: 8 oz. (227 g) approximately. Two Pole Types: 9.6 oz. (273 g) approximately Contact Ratings Full Number Line Locked Resistive Maximum Horsepower Load of Voltage Rotor Amps Voltage Single Amps Poles Amps Rating Phase 240/277 120 30 120 2 20 2 480 100 30 240 3 600 80 30 240/277 150 30 120 1 25 1 480 50 30 240 2 600 40 30 240/277 150 35 120 2 25 2 480 125 35 240 3 600 100 35 240/277 150 40 120 1 30 1 480 75 40 240 2 600 50 40 240/277 150 40 120 2 30 2 480 125 40 240 3 600 100 40 240/277 240 50 120 2 40 1 480 200 50 240 3 600 160 50 240/277 240 50 120 2 40 2 480 200 50 240 3 600 160 50 Coil Data 1-Pole Models 2-Pole Models Nominal Coil Voltage 24 120 208/240 277 24 120 208/240 277 Maximum Pickup Volts 18 88 177 221 18 88 177 221 Drop-Out Volts Range 6 - 15 20 - 70 40 - 140 50 - 165 6 - 15 20 - 70 40 - 140 50 - 165 Nominal Inrush VA 50 Hz 22.5 22.5 22.5 22.5 37 37 37 37 Nominal Inrush VA 60 Hz 20 20 20 20 35 35 35 35 Nominal Sealed VA 50 Hz 77778888 Nominal Sealed VA 60 Hz 5.25 5.25 5.25 5.25 7777 Nominal DC Resistance - Ohms 10% 16.5 440 1850 2250 11 250 1000 1600 02-2013, Rev. 0213 EU RoHS/ELV, China RoHS, REACH, Halogen content Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com refer to the Product Compliance Support Center at terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, www.te.com/customersupport/rohssupportcenter the Definitions section, available at are subject to change. 1 a TE Connectivity Ltd. company Ordering Information Typical Part No. > 3100 - 20 Q6 999 1. Series: 3100 = 1- or 2-pole, 20-40 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 10 = 1 Form X (SPST-NO-DM) 15 = 1 Form X (SPST-NO-DM) with Shunt 20 = 2 Form X (DPST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC T = 120VAC U = 208/240VAC P = 100VAC S = 200VAC V = 277VAC 5.Contact Ratings (Inductive): 1 = 25 FLA on 1-pole models 3 = 20 FLA on 2-pole models 2 = 30 FLA on 1-pole models 5 = 25 FLA on 2-pole models 14 = 35 FLA on 1-pole models 6 = 30 FLA on 2-pole models 19 - 40 FLA on 1-pole models 18 = 40 FLA on 2-pole models 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7.Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard part numbers listed below are more likely to be available from stock. 3100-15Q2999 3100-20Q6999 3100-20Q18999CL 3100-15T2999 3100-20T6999 3100-20T18999CL 3100-15U2999 3100-20U6999 3100-20U18999CL Outline Dimensions Termination Options 2.10 Max. 1-Pole (53.3) .253 (6.43) 1.625 3.30 2.313 .875 (41.28) (83.8) (57.75) (22.2) Standard Special Standard on 20, 25, 30, 35 on 20, 25, 30, 35 FLA on 40 FLA FLA 10-32 Sems Screw Lug accepts 14-4 10-32 Combination with Pressure Plate Cu/Al AWG .215 TYP (5.46) 1.625 (41.3) Phillips, Slotted & 2.00 (50.8) 5/16 Hex Head 2.445 12 Washer (62.1) 2.541 (64.5) 2.10 Max. 2-Pole (53.3) 1.625 .875 3.30 2.313 (41.28) (22.2) (83.8) (57.75) .215 TYP (5.46) 1.625 (41.3) 2.00 (50.8) 2.445 (62.1) 2.610 (66.3) ORDERING NOTE: Standard terminals need not be specified in the Ordering Information chart above. Special terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your TE sales engineer must consult with the factory before providing price and availability information regarding items with these options. 02-2013, Rev. 0213 EU RoHS/ELV, China RoHS, REACH, Halogen content Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com refer to the Product Compliance Support Center at terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, www.te.com/customersupport/rohssupportcenter the Definitions section, available at are subject to change. 2 a TE Connectivity Ltd. company