Signal Relays AXICOM FX2 Relay n Slim line 15x7.3mm (.590x.287) n 2 form C bifurcated contacts (2 CO), switching current 2A n High sensitivity for low power consumption, 80mW/140mW n High dielectric characteristic, up to 2100Vrms between open contact n High surge capability (1.2/50s and 10/700s) meets Telcordia GR 1089 and FCC Part 68, up to 2900V between open contacts, up to 6000V between coil and contacts n High mechanical shock, up to 1500g survival n Hermetically sealed (RT V) Typical applications Communications equipment, linecard application - analog, ISDN, xDSL, Z PABX, voice over IP, office and business equipment, measurement and control equipment, consumer electronics, set top boxes, HiFi, medical equipment Coil Data Magnetic system polarized, monostable, bistable Approvals Coil voltage range 3 to 48VDC UL 508 File No. E 111441 Max. coil temperature 125C. Technical data of approved types on request Thermal resistance <165K/W Contact Data Coil versions, monostable Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power Rated current 2A VDC VDC VDC VDC 10% mW Limiting continuous current 2A Standard version, monostable, 1 coil Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140 Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140 Contact style twin contacts 04 4.5 3.15 9.40 0.45 145 140 Min. recommended contact load 100V/1A 09 5 3.50 10.50 0.50 178 140 Initial contact resistance <70m 05 6 4.20 12.60 0.60 257 140 Thermoelectric potential <10V 10 9 6.30 18.90 0.90 574 140 Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140 Release time 12 24 16.80 42.20 2.40 2880 200 without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300 with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80 Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 353 80 Electrical endurance 23 5 3.50 12.50 0.50 313 80 at contact application 0 24 6 4.20 13.90 0.60 450 80 AXICOM 6 ( 30mV / 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80 6 Telecom-, Signal and RF Relays 108-98003 Rev. G cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80 5 resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140 5 FX2 Relay resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260 5 resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200 125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200 Coil Operating Range 120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200 6 All figures are given for coil without pre-energization, at ambient temperature +23C. Mechanical endurance 100x10 operations Unom = Nominal coil voltage Max. DC load breaking capacity 80 mW 140 mW Umax. = Upper limit of the operative range of 3.4 200 mW the coil voltage (limiting voltage) 3.2 Umax. at 0 A 3 Uop. min. = Lower limit of the operative range of the Umax. at 2 x 1 A 2.8 coil voltage (reliable operate voltage) Umax. at 2 x 2 A 2.6 For latching relays Uset min. resp. Ureset min. 2.4 2.2 Urel. min. = Lower limit of the operative range of 2 the coil voltage (reliable release voltage) 1.8 1.6 1.4 1.2 1 Unom. nominal coil voltage 0.8 0.6 Uop. min. 0.4 Urel. min. 0.2 0 -60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120 Ambient Temperature C DC current A 1 04-2013, Rev. 0413 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. 260 mW a TE Connectivity Ltd. company AXICOM Telecom-, Signal and RF Relays 108-98003 Rev. G FX2 Relay Coil Operating Range Unom = Nominal coil voltage 80 mW 140 mW Umax. = Upper limit of the operative range of 3.4 200 mW 3.2 the coil voltage (limiting voltage) AXICOM Umax. at 0 A 3 Uop. min. = Lower limit of the operative range of the Telecom-, Signal and RF Relays 108-98003 Rev. G Umax. at 2 x 1 A 2.8 coil voltage (reliable operate voltage) Umax. at 2 x 2 A 2.6 For latching relays Uset min. resp. Ureset min. 2.4 FX2 Relay 2.2 Urel. min. = Lower limit of the operative range of 2 the coil voltage (reliable release voltage) 1.8 1.6 Coil Operating Range 1.4 1.2 1 Unom. nominal coil voltage Signal Relays AXICOM 0.8 Unom = Nominal coil voltage 0.6 80 mW Uop. min. 140 mW 0.4 Umax. = Upper limit of the operative range of 3.4 Urel. min. 200 mW 0.2 the coil voltage (limiting voltage) 3.2 FX2 Relay (Continued) 0 Umax. at 0 A 3 -60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120 Uop. min. = Lower limit of the operative range of the Umax. at 2 x 1 A 2.8 Ambient Temperature C coil voltage (reliable operate voltage) Umax. at 2 x 2 A 2.6 2.4 For latching relays Uset min. resp. Ureset min. 2.2 Coil Data (continued) Urel. min. = InsulationLower limit of the operative range of standar d high dielectric 2 Initial dielectric strength the coil voltage (reliable release voltage) 1.8 260 mW between open contacts 1800V 2100V 1.6 rms rms 2.6 300 mW 1.4 between contact and coil 1800V 4000V rms rms 2.4 1.2 between adjacent contacts 1800V 2100V rms rms Umax. at 0 A 2.12 Unom. nominal coil voltage Umax. at 2 x 1 A Initial surge withstand voltage 0.8 2.0 Umax. at 2 x 2 A between open contacts 2500V 2900V 0.6 Uop. min. 1.8 0.4 between contact and coil 3500V 6000V Urel. min. 0.2 1.6 between adjacent contacts 2500V 2900V 0 1.4 Initial insulation resistance -60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120 9 9 1.2 Ambient Temperature C between insulated elements >10 >10 1.0 Capacitance Unom. nominal coil voltage 0.8 between open contacts max. 4pF 0.6 between contact and coil max. 2pF Uop. min. 0.4 between adjacent contacts max. 2pF 260 mW Urel. min. 2.6 300 mW Cross talk at 100MHz/900MHz -34.0dB/-15.1dB 0.2 2.4 Insertion loss at 100MHz/900MHz 0.03dB/0.60dB 0.0 Umax. at 0 A -60-50 -40-30 -20-10 0102030405060708090 100 110 120 2.2 Voltage standing wave ratio (VSWR) Umax. at 2 x 1 A Ambient Temperature C 2.0 at 100MHz/900MHz 1.07/1.45 Umax. at 2 x 2 A Coil versions, bistable 1 coil 1.8 Coil Rated Set Limiting Reset Coil Rated coil 1.6 code voltage voltage voltage voltage resistance power Other Data 1.4 4.4 VDC VDC VDC VDC100 mW Latching 10% mW Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 1.2 4.2 Standard, bistable 1 coil refer to the Product Compliance Support Center at 4 1.0 3.8 41 U3nom . nominal coil voltage2.25 7.50 -2.25 90 100 www.te.com/customersupport/rohssupportcenter 0.8 3.6 42 4.5 3.38 11.20 -3.38 203 100 Ambient temperature -40C to +85C 3.4 0.6 3.2 43 5 3.75 12.40 -3.75U op. min. 250 100 Category of environmental protection 0.4 3 Urel. min. 44 6 4.50 14.90 -4.50 360 100 IEC 61810 RT V - immersion cleanable 2.8 0.2 2.6 45 9 6.75 22.40 -6.75 810 100 Degree of protection, IEC 60529 IP 67, immersion cleanable 0.0 2.4 -60-50 -40-30 -20-10 0102030405060708090 100 110 120 46 12 9.00 29.80 -9.00 1440 100 Vibration resistance (functional) 20g, 10 to 500Hz 2.2 2 47 U24max. - 100 % coil duty at 0 18.00Ambient Temperature C 48.70A -18.00 3840 150 Shock resistance (functional), half sinus 11ms 50g 1.8 Umax. - 5 % coil duty at 2 x 2 A High dielectric version, bistable 1 coil Shock resistance (destructive), half sinus 0.5ms 1500g 1.6 Umax. - 5 % coil duty at 2 x 1 A 1.4 62 4.5 3.15 11.20 -3.15 203 100 Weight max. 2.5g 1.2 Umax. - 5 % coil duty at 0 A All figures are given for coil without pre-energization, at ambient temperature +23C. Resistance to soldering heat THT 1 Unom. nominal coil voltage 4.0.84 IEC 60068-2-20 265C/10s 100 mW Latching 0.4.26 Ultrasonic cleaning not recommended 0.44 Uset min. 0.2 Packaging/unit tube/50 pcs., box/1000 pcs. 3.8 0 3.6 -60-50 -40-30 -20-10 0102030405060708090100 110120 130140 3.4 Ambient Temperature C 3.2 3 2.8 2.6 All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 11 2.4 2.2 2 Umax. - 100 % coil duty at 0 A 1.8 Umax. - 5 % coil duty at 2 x 2 A 1.6 Umax. - 5 % coil duty at 2 x 1 A 1.4 Umax. - 5 % coil duty at 0 A 1.2 1 Unom. nominal coil voltage 0.8 0.6 0.4 Uset min. 0.2 0 -60-50 -40-30 -20-10 0102030405060708090100 110120 130140 Ambient Temperature C Other coil voltages on request. U upper limit of the operative range of the coil voltage (limiting voltage) when coils are max All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 11 continuously energized U lower limit of the operative range of the coil voltage (reliable operate voltage) op min U lower limit of the operative range of the coil voltage (reliable release voltage) rel min Terminal assignment TOP view on component side of PCB PCB layout TOP view on component side of PCB Monostable Bistable, 1 coil Contacts are shown in reset condition. Both coils can be used as either set or reset coils. Contact position might change during transportation and must be reset before use. 2 04-2013, Rev. 0413 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company