General Purpose Relays Industrial Relays SCHRACK Power Relay RM C/D n 1 pole 30/32 A, 1 form X, double make, NO or 1 form Z, double make + double break, NO + NC n Switching capacity up to 12800VA n DC or AC coil n Push-to-test button n Chassis mount Typical applications Battery chargers, heating control F0166-B Z Approvals Coil Data UL E214025, VDE 40003144 for AgNi-versions Coil voltage range 6 to 220 VDC Technical data of approved types on request 6 to 400 VAC Operative range, IEC 61810 2 Contact Data RMC RMD Coil insulation system according UL class 130 (B) Contact arrangement 1 form Z, 1 form X, 1 NO + 1 NC 1 NO Coil versions, DC coil Rated voltage 400VAC Coil code Rated Coil Rated coil 3) Max. switching voltage 440VAC STD LED PD LED+ voltage resistance power 3) 1)2) Rated current 30A/32A (VDE) bipolar PD VDC 10% W Limiting making current, max. 20ms 60A 006 L06 0A6 LA6 6 32 1.1 Switching power 7500VA 012 L12 0B2 LB2 12 110 1.3 Contact material AgCdO, AgNi 90/10 024 L24 0C4 LC4 24 475 1.2 Contact style single bridging contact 048 L48 0E8 LE8 48 2000 1.2 Min. recommended contact load 24VDC/100mA 060 L60 0G0 LG0 60 2850 1.3 1) Frequency of operation, 110 M10 1B0 MB0 110 10000 1.2 -1 2) with/without load, DC coil 960/6000h 221 N21 2C1 NC1 220 40000 1.2 Operate/release time max., DC coil 20/20ms Operate voltage, DC coil 75% of rated coil voltage Bounce time max., form A/form B, DC coil 4/6ms Release voltage, DC coil 10% of rated coil voltage 1) Coil resistance 12%, 2) Coil resistance 15% 3) Protection diode PD standard polarity: +A1 / -A2 Contact ratings All figures are given for coil without pre-energization, at ambient temperature +23C Type Contact Load Cycles EN 61810 RMC/D X of Z (NO), AgNi 32A, 400VAC res. 40C 20x10 RMC Y of Z (NC), AgNi 32A, 400VAC res. 40C 10x10 RMC/D X of Z (NO) AgNi DC coil 30A, 400VAC res. 50C 10x10 RMC/D X of Z (NO) AgNi AC coil 30A, 400VAC res. 40C 10x10 UL 508 RMC/D X/Y (NO/NC), 3 AgCdO, 30 A, 277 VAC, general purpose 50C 10x10 3 RMC/D X/Y (NO/NC) 30 A, 415 VAC, resistive 50C 10x10 3 RMC/D X (of Z / NO), AgNi 120 VAC, 0,75 HP 50C 10x10 3 RMC/D X/Y (NO/NC) 240 VAC, 2 HP 50C 6x10 Mechanical endurance 6 DC coil 10x10 operations 6 AC coil 10x10 operations 1 04-2011, Rev. 0411 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays Industrial Relays SCHRACK Power Relay RM C/D (Continued) Coil Data (continued) Terminal assignment Bottom view on pins Coil versions, AC coil Coil code Rated Operate Release Coil Rated coil STD LED voltage voltage voltage resistance power 50/60Hz 50/60Hz 50/60Hz 1)2) VAC VAC VAC 10% VA Coil versions, AC-coil, RMC, RMD 524 R24 24 19.2/20.4 7.2 80 2.62/2.00 548 R48 48 38.4/40.8 14.4 320 2.60/2.17 560 R60 60 48.0/51.0 18.0 500 2.62/2.20 615 S15 115 92.0/97.8 34.5 1850 2.65/2.22 730 T30 230 184.0/195.5 69.0 7500 2.69/ 2.26 2) 900 V00 400 320.0/340.0 120.0 23500 2.61/2.20 2) Coil resistance 15% All figures are given for coil without pre-energization, at ambient temperature +23C S0269-AK Insulation Data RMC RMD Initial dielectric strength between open contacts 1500Vrms 2000Vrms 1 form Z contact (1 NO + 1 NC), RMC between contact and coil 2500Vrms 2500Vrms Initial surge withstand voltage between contact and coil 6000V (1.2/50s) Clearance/creepage between contact and coil 4.0/14.9mm Material group of insulation parts IIIa Other Data S0269-AH Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter 1 form X contact (1 NO), RMD Ambient temperature DC coil -45 to +60C AC coil -45 to +40C Cold storage, IEC 60068-2-1 Test Aa (-40C/16h) Dry heat, IEC 60068-2-2 Test B (+85C/16h) Damp heat cyclic, IEC 60068-2-30, Db, Variant 1 12/12h +25/55C 2 cycles Category of environmental protection IEC 61810 RTI - dust protected Vibration resistance (functional) S0269-AI form A (NO)/form B (NC) 10/5 g, 30 to 150Hz Terminal type quick-connect (QC) Cover retention pull force 100N push force 100N Weight 81g Packaging unit 10 pcs. Dimensions Cover with mounting brackets, 6.3 mm quick connect terminals Dimensions in mm S0298-BK 2 04-2011, Rev. 0411 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company