Signal Signal Relays AXICOM FP2 Relay n Telecom/signal relay (dry circuit, test access, ringing) n Slim line 14x9mm (.551x.354) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitivity results in low nominal power consumption, 80mW for high sensitive, 140mW for sensitive version n High mechanical shock resistance, up to 300g functional, up to 1500g survival Typical applications Communications equipment linecard application (ringing and test access), PABX, voice over IP, office equipment, measurement and control equipment, automotive equipment as CAN bus, keyless entry, speaker switch, medical Z equipment, consumer electronics, set top boxes, HiFi. Approvals Coil Data UL 508 File No. E 111441, UL 60950, Magnetic system polarized Technical data of approved types on request Coil voltage range 2 to 24VDC Max. coil temperature 125C Contact Data Thermal resistance < 125K/W Contact arrangement 2 form C (CO) Max. switching voltage 220VDC, 250VAC Coil versions, monostable Rated current 2A Coil Rated Operate Limiting Release Coil Rated coil Limiting continuous current, 85C 2A code voltage voltage Voltage voltage resistance power Switching Power 60W, 62.5VA VDC VDC VDC VDC 10% mW Contact material AgNi, gold-covered Standard version, monostable Contact style bifurcated contact 06 3 2.10 6.60 0.30 64 140 Minimum switching voltage 100V 04 4.5 3.15 9.90 0.45 145 140 Thermoelectrical potential <10V 09 5 3.50 11.00 0.50 178 140 Initial contact resistance <50m at 10mA, 20mV 05 6 4.20 13.20 0.60 257 140 Frequency of operation, without load 50 operations/s 10 9 6.30 19.80 0.90 574 140 Operate time typ. 2ms, max. 4ms 02 12 8.40 26.40 1.20 1028 140 Set/reset time typ. 2ms, max. 4ms 12 24 16.80 44.30 2.40 2880 200 Release time 13 48 33.60 72.30 4.80 7680 300 without diode in parallel typ. 2ms, max. 4ms with diode in parallel typ. 4ms, max. 6ms High sensitive version, monostable Bounce time typ. 1ms, max. 3ms High sensitive version, monostable Electrical endurance 21 3 2.10 8.70 0.30 113 80 7 at 12V / 10mA typ. 5x10 operations 22 4.5 3.15 13.10 0.45 353 80 Telecom-, Signal and RF Relays 108-98005 Rev. E 7 23 5 3.50 14.60 0.50 313 80 at 6V / 100mA typ. 1x10 operations 5 at 60V / 500mA typ. 5x10 operations 24 6 4.20 17.50 0.60 450 80 6 FP2 Relay at 30V / 1000mA typ. 1x10 operations 25 9 6.30 24.20 0.90 1013 80 5 at 30V / 2000mA typ. 2x10 operations 26 12 8.40 35.00 1.20 1800 80 UL contact rating 50VDC / 2A - 100W 27 24 16.80 52.80 2.40 4114 140 50VAC / 2A - 100W 28 48 36.00 77.60 4.80 8882 260 Coil Operating Range All figures are given for coil without pre-energization, at ambient temperature +23C. 30VDC / 2A - 60W 6 Mechanical endurance typ. 100x10 operations U = Nominal coil voltage nom 3.4 80 mW Max. DC load breaking capacity 3.2 140 mW U = Upper limit of the operative range of max 200 mW 3 the coil voltage (limiting voltage) 2.8 Umax. at 0 A 2.6 Umax. at 2 x 1 A U = Lower limit of the operative range of op. min. 2.4 Umax. at 2 x 2 A the coil voltage (reliable operate voltage) 2.2 2 For latching relays U resp. U set min. reset min. 1.8 1.6 U = Lower limit of the operative range of rel. min. 1.4 the coil voltage (reliable release voltage) 1.2 1 Unom. nominal coil voltage 0.8 0.6 Uop. min. 0.4 Urel. min. 0.2 0 -60 -50 -40 -30 -20 -10 0102030405060708090100 110120 DC current A Ambient Temperature C 1 10-2012, Rev. 1012 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, 2.6 www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 260 mW 2.4 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. 300 mW a TE Connectivity Ltd. company. Telecom-, Signal and RF Relays 108-98005 Rev. E FP2 Relay Coil Operating Range U = Nominal coil voltage nom 3.4 80 mW 3.2 140 mW U = Upper limit of the operative range of max 200 mW 3 the coil voltage (limiting voltage) 2.8 Umax. at 0 A 2.6 Umax. at 2 x 1 A U = Lower limit of the operative range of op. min. 2.4 Umax. at 2 x 2 A the coil voltage (reliable operate voltage) 2.2 2 For latching relays U resp. U set min. reset min. 1.8 1.6 Signal U = Lower limit of the operative range of rel. min. 1.4 the coil voltage (reliable release voltage) 1.2 Signal Relays AXICOM 1 Unom. nominal coil voltage 0.8 0.6 Uop. min. 0.4 Telecom-, Signal and RF RelaysFP2 Relay (Continued) 108-98005 Rev. E Urel. min. 0.2 0 -60 -50 -40 -30 -20 -10 01020304FP2 Rela0506070809y0100 110120 Ambient Temperature C Coil Data (continued) Insulation Initial dielectric strength Coil Ope2.6 rating Range between open contacts 750V rms 260 mW 2.4 between contact and coil 1000V rms 300 mW 2.2 between adjacent contacts 1000V rms U = Nominal coil voltage 3.4 nom Umax. at 0 A 80 mW Initial surge withstand voltage 2.0 3.2 Umax. at 2 x 1 A 140 mW between open contacts 1100V U = Upper limit of the operative range of 1.8 max 200 mW 3 Umax. at 2 x 2 A between contact and coil 1500V the coil voltage (limiting voltage) 1.6 2.8 Umax. at 0 A between adjacent contacts 1500V 2.6 1.4 Umax. at 2 x 1 A U = Lower limit of the operative range of op. min.Initial insulation resistance 2.4 Umax. at 2 x 2 A 1.2 9 the coil voltage (reliable operate voltage) between insulated elements >10 2.2 1.0 2 Capacitance For latching relays U resp. U Unom. nominal coil voltage set min. reset min. 0.8 1.8 between open contacts max. 4pF 1.6 0.6 U = between contact and coilLower limit of the operative range of max. 1pF rel. min. 1.4 between adjacent contacts max. 1pF 0.4 Uop. min. the coil voltage (reliable release voltage) 1.2 Urel. min. Cross talk at 100MHz/900MHz -40.2dB/-22.3dB 0.2 1 Unom. nominal coil voltage Insertion loss at 100MHz/900MHz 0.03dB/0.25dB 0.8 0.0 -60-50 -40-30 -20-10 0102030405060708090100 110 120 Voltage standing wave ratio (VSWR) 0.6 Uop. min. Ambient Temperature C 0.4 at 100MHz/900MHz 1.01/1.07 Urel. min. 0.2 0 Coil versions, bistable -60 -50 -40 -30 -20 -10 0102030405060708090100 110120 4.6 Coil Rated Set Max. set Reset Coil Rated coil Other Data 200 mW Latching Ambient Temperature C 4.4 100 mW Latching code voltage voltage voltage voltage resistance power Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 4.2 4 VDC VDC VDC VDC 10% mW refer to the Product Compliance Support Center at 3.8 Umax. - 100 % coil duty at 0 A Standard, bistable 1 coil2.6 3.6 www.te.com/customersupport/rohssupportcenter 3.4 260 mW 41 3 2.25 7.80 -2.25 90 1002.4 Ambient temperature -40C to +85C 3.2 300 mW 42 4.5 3.38 11.70 -3.38 203 1003 Thermal resistance <150K/W 2.2 2.8 43 5 3.75 13.00 -3.75 250 100Umax. at 0 A Category of environmental protection 2.0 2.6 Umax. at 2 x 1 A 44 6 4.50 15.60 -4.50 360 1002.4 IEC 61810 RT III - immersion cleanable 1.8 2.2 Umax. at 2 x 2 A 45 9 6.75 23.50 -6.75 810 100 Degree of protection, IEC 60529 IP 67, immersion cleanable 2 1.6 46 12 9.00 31.30 -9.00 1440 1001.8 Umax. - 5 % coil duty at 2 x 2 A Vibration resistance (functional) 20g, 10 to 500Hz 1.1.64 Umax. - 5 % coil duty at 2 x 1 A 47 24 18.00 47.50 -18.00 3840 150 Shock resistance (functional), half sinus 11ms 50g 1.4 1.2 Umax. - 5 % coil duty at 0 A Standard, bistable 2 coils1.2 Shock resistance (destructive), half sinus 0.5ms 1500g 1 Unom. nominal coil voltage 1.0 61 3 2.10 5.50 -2.10 45 200 Terminal type PCB-THT 0.8 Unom. nominal coil voltage 62 4.5 3.15 8.30 -3.15 101 2000.0.68 Weight max. 2g 0.4 63 5 3.20 7.20 -3.20 125 200 Resistance to soldering heat THT 0.6 0.2 Uset min. 64 6 4.20 11.10 -4.20 180 2000 IEC 60068-2-20 265C/10s 0.4 Uop. min. -60-50 -40-30 -20-10 0102030405060708090100 110 120 130 140 65 9 6.30 16.80 -6.30 405 200 Ultrasonic cleaning not recommended Urel. min. 0.2 Ambient Temperature C 66 12 8.40 28.10 -8.40 720 200 Packaging unit tube/50 pcs., box/1000 pcs. 0.0 67 24 16.80 44.30 -16.80 1920 300-60-50 -40-30 -20-10 0102030405060708090100 110 120 All figures are given for coil without pre-energization, at ambient temperature +23C. Ambient Temperature C All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 11 4.6 200 mW Latching 4.4 100 mW Latching 4.2 4 3.8 Umax. - 100 % coil duty at 0 A 3.6 3.4 3.2 3 2.8 2.6 2.4 2.2 2 1.8 Umax. - 5 % coil duty at 2 x 2 A 1.6 Umax. - 5 % coil duty at 2 x 1 A 1.4 Umax. - 5 % coil duty at 0 A 1.2 1 Unom. nominal coil voltage 0.8 0.6 0.4 Uset min. 0.2 0 -60-50 -40-30 -20-10 0102030405060708090100 110 120 130 140 Ambient Temperature C All figures are given for coil without pre-energization, at ambient temperature +23C. All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 11 U upper limit of the operative range of the coil voltage (limiting voltage) when coils are max continuously energized U lower limit of the operative range of the coil voltage (reliable operate voltage) op min U lower limit of the operative range of the coil voltage (reliable release voltage) rel min 2 10-2012, Rev. 1012 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company.