SPECIFICATION CONTROL DRAWING 44A7434 TITLE Date Revision TWO CONDUCTOR THERMOCOUPLE EXTENSION CABLE 10-9-04 U This specification sheet forms a part of the latest issue of Raychem Specification 44. COMPONENT WIRES - 1 of WTC-0013 (CHROMEL) 1 of WTC-0014 (ALUMEL) CABLE CONSTRUCTION DETAILS MAXIMUM OUTSIDE DIAMETER CONDUCTOR WEIGHT PART NUMBER (in.) SIZE (lb/1000 ft) 1/ (AWG) NOMINAL MAXIMUM .108 5.5 44A7434-24-* 24 .104 44A7434-22-* 22 .118 .124 7.5 20 .140 .147 11.2 44A7434-20-* ADDITIONAL REQUIREMENTS PART NUMBER: TEMPERATURE RATING: 150C The in the part numbers above shall be replaced Maximum continuous conductor temperature by color code designators with a slash separating INSULATION FLAWS: component wire colors: Spark Test, 1.5 kV (rms) The color of CHROMEL shall be shown first. Impulse Dielectric Test, 8.0 kV (peak) 1/ Example: AWG 20: Component colors per MIL-STD-687: white and green: 44A7434-20-9/5 Component colors per ANSI MC96.1: yellow and red: 44A7434-20-4/2 Component colors per British Standard Code BS: brown and blue: 44A7434-20-1/6 PRODUCT IDENTIFICATION: The white wire shall be marked in black ink at 6 inch (nominal) intervals between marks as follows: 44A7434-AWG - 06090 . The combination of the above thermoelements is referred to as Type KX per ANSI MC96.1. EMF shall be 4.00 mV (minimum), 4.19 mV (maximum), at 100C with reference junction at 0C per ANSI MC96.1, and shall be performed on every length of finished cable. CHROMEL and ALUMEL are federally registered trademarks of Hoskins Manufacturing Company. Alternative conductors, exhibiting the same performance characteristics, may be substituted for one or both of the CHROMEL and ALUMEL conductors. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297