REV B High Voltage Gas-Filled Relay Features Physical: Hermetically Sealed: arc contained Maintenance free Environmental: Temperature range -55C to 125C 50G Shock Power Switching: Gas filled for Make only power switching Used for capacitive discharge applications Coil Voltage: 12, 26.5, 115 Vdc Standard P.O. Box 4422, Santa Barbara, CA 93140 Phone (805) 684-4560 Fax (805) 684-9679 E-Mail: info ciitech.com Internet: General Specifications B Physical Data Units Contact Arrangement SPDT Form C Weight oz 1 Environmental Data Shock, 11ms sine g 50 peak Vibration, 10 g Hz 55-2000 peak Operating Temperature Range -55 to +125 C Electrical Data Test Voltage (dc or 60 Hz) kV 5 peak Rated Operating Voltage (dc or 60 Hz) kV 3.5 peak Coil Hi-Pot Vrms 500 Continuous Current Carry, Contacts Closed (dc or 60 Hz) A 8 Contact Resistance, maximum* Ohms 0.50 Mechanical Life cycles 1,000,000 Mechanical Data Operate Time, Maximum ms 6 Release Time, Maximum ms 6 1. RATINGS LISTED ARE FOR 25 C SEA LEVEL CONDITIONS. 2. RELAY BASE MUST BE GROUNDED *CONTACT RESISTANCE FOR GAS FILLED RELAYS IS MEASURED AT 28 Vdc, 1 Ampere P.O. Box 4422, Santa Barbara, CA 93140 Phone: (805) 684-4560 Fax: (805) 684-9679 E-Mail: info ciitech.com Internet: