SPECIFICATION CONTROL DRAWING 7528F5614 9-28-16 Date: 75 OHM, AWG 28, 7 STRANDS OF AWG 36, TRIAXIAL CABLE CHEMINAX H Revision: THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS OTHERWISE DESIGNATED. CHARACTERISTIC IMPEDANCE 75 3 ohms, Method B CAPACITANCE 17.7 pF/ft. (nominal) 19.5 pF/ft. (maximum) VELOCITY OF PROPAGATION 77% (nominal) CONDUCTOR .0150 AWG 28, 7 Strands of AWG 36, Silver-Coated High- ADDITIONAL REQUIREMENTS Strength Copper Alloy .065 DIELECTRIC ELECTRICAL (nominal) Radiation-Crosslinked, .068 CONDUCTOR RESISTANCE 74.0 ohms/1000 ft. (nominal) Foamed PE (maximum) Color - Natural INSULATION RESISTANCE 10,000 megohms (minimum) CONDUCTOR TO SHIELD for 1000 ft082 JACKET FLAWS 1st SHIELD (nominal) SPARK TEST 1.0 kV (rms) AWG 38, .085 IMPULSE TEST 6.0 kV (peak) Tin-Coated Copper (maximum) VOLTAGE WITHSTAND CONDUCTOR TO SHIELD 1000 volts (rms) (minimum) SHIELD TO SHIELD 500 volts (rms) (minimum) 1st JACKET Radiation-Crosslinked, .100 Modified ETFE Color - White ENVIRONMENTAL FLAMMABILITY Method B HEAT SHOCK 225C 2nd SHIELD AWG 38, LOW TEMPERATURE-COLD BEND -55C/3.75 inch mandrel .117 Tin-Coated Copper VOLTAGE WITHSTAND 1000 volts (rms), 1 minute (Post Environmental) PHYSICAL INSULATION (DIELECTRIC) .135 2nd JACKET ELONGATION 50% (minimum) (nominal) Radiation-Crosslinked, 2 TENSILE STRENGTH 1000 lbf/in (minimum) .141 Modified ETFE (maximum) JACKET (each) ELONGATION 50% (minimum) 2 TENSILE STRENGTH 5000 lbf/in (minimum) JACKET THICKNESS (each) .009 inch (nominal) SHIELD COVERAGE (each) 90% (minimum) Designate outer jacket color with a dash number in accordance with MIL-STD-681. Unless otherwise specified, outer jacket color WEIGHT 15.7 lbs/1000 ft. (nominal) will be white designated by a-9 appended to the part number, (e.g. 7528F5614-9). ENGINEERING REFERENCE Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the TEMPERATURE RATING 115C (maximum) purchase order. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 1 Cheminax, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. 501 Oakside Avenue REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Redwood City, California 94063-3800 2016 Tyco Electronics Corporation. All rights reserved. Phone: 1-800-522-6752 Fax: 1-650-361-6297 X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Coaxial Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89880-003-1000 89913-010-1000 633938-009-U1000 633948-877-1000 639948-877-1000 643948-877-U1000 CY2389-000 8213-010-1000 8221-010-U1000 8233-010-1000 88281-010-500 1322R-010-1000 1505A-N3U-1000 1523AP-010-1000 1807A-B59-U1000 9167-010-1000 9251-010-1000 9275-010-U1000 935240-000 9659-010-1000 980704-001 1855P-010-1000 CF2823-000 33312-010-500 CY2581-000 CY2582-000 CZ1589-000 5022W0809-0CS3263 10610-4-4 EF8108-000 6139B8-009-1000 613948-009-1000 1673B TIN100 633938-877- U1000 672525-001 1530AP-877-1000 144517-000 1369R-010-1000 134655-000 8-1616396-1 8263-010-U1000 8263 010U500 480414- 000 8262 010U1000 7915A 009U1000 5024A1311-0 TRC-75-1 1281S5 010250 1281S5 000250 1530A 010U1000